In detail. Shore power connection unit LAE 232.

  • Residual current and personal protection by the RCBO circuit breaker (16 A / 30 mA)
  • Two additional two-pole thermal circuit breakers (10 A) for subordinate protection of downstream circuits
  • Back-of-hand safe rear-mounted construction protects against electric shock with proper installation
  • Compatible with philippi Series 200 circuit distribution panels, including labeling set

The LAE 232 from philippi supplies the on-board electrical system with AC 230 V / 50 Hz and protects the power input via an RCBO circuit breaker (16 A / 30 mA) and two two-pole thermal circuit breakers (10 A). A mains indicator shows the mains status, and connection is made via rear terminals. The rear electrical construction is designed to be back-of-hand safe; the panel must be installed so that the rear side is only accessible and covered with tools.

If the supply point is more than 3 m away from the LAE 232, the supply cable must be additionally protected with an MCB circuit breaker (e.g., philippi LAE 205) near the supply point. The scope of delivery includes an SKZ labeling set for boats and black mounting screws; an SKZ-MOBIL labeling set for vehicles is optionally available.

Compatibility: The LAE 232 is designed to match the philippi Series 200 circuit distribution panels. If the distance to the supply point is more than 3 m, philippi additionally recommends the MCB circuit breaker LAE 205.

Original equipment quality

  • Individually tested: every unit is connected and tested in a test environment in Remseck.
  • Brand-name components, as in series production for boatyards.
  • Repairable for decades: spare parts up to 30 years back, own repair centre.
How we manufacture

Technical data

Feature Value
Nominal voltage AC 230 V / 50 Hz
RCBO circuit breaker 16 A / 30 mA
Thermal circuit breakers 2 x 2-pole, 10 A
Connection rear terminals
Dimensions W 105 x H 210 x D 100 mm
Mounting cutout 81 x 186 mm
Scope of delivery SKZ labeling set, mounting screws (optional SKZ-MOBIL)
Item No. 010002320

Manufacturer and product safety

philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Deutschland
info@philippi-online.de

Safety information: see the operating manual and data sheet.

Frequently asked questions. Answered briefly.

Which circuit distribution panels is the LAE 232 compatible with?

The LAE 232 is designed to be compatible with the philippi Series 200 circuit distribution panels.

Do I need to consider anything if the distance to the supply point is greater?

Yes, if the distance to the supply point is more than 3 m, the supply cable must be additionally protected near the supply point by an MCB circuit breaker (e.g., LAE 205).

Which circuit breakers are installed in the LAE 232?

An RCBO circuit breaker (16 A / 30 mA) and 2 two-pole thermal circuit breakers (10 A) for AC 230 V / 50 Hz.

Is the LAE 232 also suitable for vehicles?

Yes, an optional SKZ-MOBIL labeling set is available for installation in vehicles.