In detail. Circuit breaker LAE 205 for shore power supply cables.

  • Protects the cable section in front of the shore power unit against overload and short circuit
  • Double-pole: phase and neutral are disconnected together
  • IP 65 housing with hinged lid, 80 × 150 × 97 mm

The RCBO of a shore power unit only protects from the unit onwards. If it sits far from the inlet, for example at the chart table or at the front of the living cabin, the cable in front of it would remain unprotected. The philippi installation manuals therefore require the LAE 205 close to the inlet from a cable length of 3 m. It complements the philippi shore power units, for example LAE 113, LAE 220 or LAE 232.

L and N are connected to the circuit breaker, the protective earth to a terminal strip in the housing. The installation manual requires at least 3 × 2.5 mm² and intends the LAE 205 for indoor installation, not outside. Work on 230 V must only be carried out by a qualified electrician.

Goes with: all shore power units, CEE inlets and shore power cables, background on the shore power page.

Original equipment quality

  • Individually tested: every unit is connected and tested in a test environment in Remseck.
  • Brand-name components, as in series production for boatyards.
  • Repairable for decades: spare parts up to 30 years back, own repair centre.
How we manufacture

Technical data

FeatureValue
Mains voltageAC 230 V / 50 Hz
Circuit breakerMiniature circuit breaker (MCB) 16 A, 30 mA, double-pole
HousingPlastic with hinged lid
Protection classIP 65
Installation locationInside boat or vehicle, close to the inlet
Conductor cross-sectionmin. 3 × 2.5 mm²
ApplicationShore power cable longer than 3 m; boat, yacht, expedition and off-road vehicle
Dimensions (W × H × D)80 × 150 × 97 mm
Item no.010002050

Manufacturer and product safety

philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Germany
info@philippi-online.de

Safety information: see the operating manual and data sheet.

Reviews. Unfiltered, via Judge.me.

5.0 out of 5

1 review on Judge.me

  • 5 ★ 1
  • 4 ★ 0
  • 3 ★ 0
  • 2 ★ 0
  • 1 ★ 0
  • Wie immer perfekt, gerne wieder.

    Volker Pampus · Verified purchase ·

Frequently asked questions. Answered briefly.

When do I need the LAE 205?

Whenever the cable from the inlet or CEE inlet socket to the shore power unit is longer than 3 m. With reference to DIN EN ISO 13297, the philippi installation manuals require an additional circuit breaker close to the inlet in this case. With a shorter cable, the RCBO of the shore power unit alone provides protection.

Which shore power units is the LAE 205 combined with?

With the philippi shore power units with 16 A circuit breaker as soon as the 3 m limit is exceeded: the panel-mount units LAE 100, 101 and 113, the housed units LAE 211, 220 and 230 and the series 200 panels such as LAE 232 or LAE 235. The LAE 205 sits close to the inlet, the shore power unit where the on-board network is distributed.

May the LAE 205 be mounted outside?

No. According to the installation manual, the LAE 205 belongs inside the boat or vehicle, not outside. It is mounted as close as possible to the inlet or CEE inlet socket so that the cable section in between stays short. Protection class IP 65 protects the housing against dust and water jets but does not replace a protected location.

Goes well with it. Accessories and add-ons.

Prefer a quick chat?

Tell us what you are planning. We will tell you honestly what you need and what you don’t.

Beratung bei philippi in Remseck am Neckar