Grid control panel LAR
The philippi Mains Control Panel LAR is a compact shore power unit that immediately indicates via a light display whether the AC onboard electrical system is correctly connected to the AC shore power system – suitable for the Series 200 circuit distributors on board yachts.
- For safe shore power connection
In detail. Grid control panel LAR.
- Detects swapped phase (L) and neutral (N) at a glance before consumers are connected
- Reliably warns with a red light in case of incorrect connection, green light confirms a correct shore connection
- Compact design for space-saving installation in the switch cabinet or in the shore power distribution panel
The measuring leakage current of the LAR is 1.4 mA. The panel is not suitable for AC networks without a protective conductor, as error detection is not possible there. Consumer supply lines are connected via flat spade terminals (6.3 mm) on the rear; this is designed to be touch-safe to prevent electric shock but must still be installed so that it is only accessible with tools and is covered.
Compatibility: The LAR is intended as an addition to the philippi Series 200 DC circuit distributors.
Original equipment quality
- Individually tested: every unit is connected and tested in a test environment in Remseck.
- Brand-name components, as in series production for boatyards.
- Repairable for decades: spare parts up to 30 years back, own repair centre.
Technical data
| Feature | Value |
|---|---|
| Measuring Leakage Current | 1.4 mA |
| Connection | Flat spade terminals 6.3 mm (rear) |
| Dimensions (W x H x D) | 105 x 52.5 x 50 mm |
| Mounting Cutout | 81 x 28.5 mm |
| SKU | 010000231 |
Manufacturer and product safety
philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Deutschland
info@philippi-online.de
Safety information: see the operating manual and data sheet.
Frequently asked questions. Answered briefly.
What does the red indicator on the LAR mean?
Red light indicates that the phase (L) and neutral (N) are connected incorrectly (swapped).
Is the LAR suitable for all AC networks?
No, it is not suitable for AC networks without a protective conductor, as error detection is not possible there.
How is the LAR connected?
Consumer supply lines are connected via flat spade terminals (6.3 mm) on the rear.