philippi Academy

Installing tank senders and sensors: ultrasonic, pressure probe, Gobius

By Michael KögelLast reviewed

In short

The right tank sender depends on medium, tank shape, tank material and access. The UTV ultrasonic sender needs a 36 or 40 mm hole and has a 2.5 cm dead zone, the TDS and TDN pressure probes measure regardless of tank shape, the Gobius C measures from outside without a tank opening, and the DFS 24 counts water consumption instead of the level.

This product help collects the installation guides for tank senders and sensors: ultrasonic sender UTV, tank probes TDS and TDN, Gobius C from outside and flow sensor DFS 24. Which measuring principle suits which tank is explained in the article Which tank sender suits my tank; the tank sender finder leads step by step to the right choice.

Ultrasonic tank sender UTV

The UTV needs a 36 or 40 mm hole and has a dead zone of 2.5 cm directly below the sensor, which the UTS 25 spacer ring compensates. A sound guide tube is part of it, and not every tank is suitable for ultrasound.

Tank probes TDS and TDN

Hydrostatic probes measure regardless of tank shape, even with keel shapes and intermediate floors. The air tube in the cable compensates for air pressure; which version is approved for which medium is stated in the guide.

Gobius C from outside

The Gobius C measures without a tank opening and is glued on from outside. The bonding surface decides the result; special rules apply to metal tanks, and setup is done via app.

Consumption instead of level: DFS 24

The DFS 24 flow sensor counts the amount of water actually drawn instead of estimating the level. For fresh water, the article on the water tank compares all five methods: immersion tube sender TGW, pressure probe TDN 200, ultrasonic sender UTV, Gobius C and DFS 24. Tank material, tank shape and access to the tank decide.

· Managing Director, philippi elektrische systeme GmbH

Michael Kögel is Managing Director of philippi elektrische systeme GmbH in Remseck am Neckar. Since 1978, the family-owned company has developed and manufactured on-board electrical systems for yachts, motorhomes and special vehicles.

Diplom-Ingenieur (Dipl.-Ing.), electrical engineering, with philippi for more than 35 years. Articles in the philippi Academy are written together with the engineering department and technically reviewed.

Published · Last reviewed

Technical

Your case isn't covered?
Ask us.

Our team knows every component and usually replies on the same working day, by email or by phone.

philippi tote bag and catalogue