Measuring the level in a water tank: five methods compared
In short
For fresh water there are five options: the TGW tube sender from above, the TDN 200 pressure probe at the bottom of the tank, the UTV ultrasonic sender without contact with the water, the Gobius C measuring through the tank wall from outside, and the DFS 24 flow sensor in the line, which counts consumption in litres. Which one fits depends on tank material, tank shape and access to the tank.
The methods at a glance
| Method | Installation | Resolution | Signal | Best for |
|---|---|---|---|---|
| TGW tube sender | from above into a tank opening | steps of 16 mm | 8–180 Ω | regular tanks, existing round gauges |
| TDN 200 pressure probe | from above down to the tank bottom | 1 cm, up to 200 cm tank height | 4–20 mA | any tank shape, tall tanks too |
| UTV ultrasonic sender | from above, contact-free | averaging over 50 s | 0.5–2.5 V | fresh and grey water, when nothing should go into the water |
| Gobius C | bonded to the outside of the tank wall | ±2–3 mm | 0–190 Ω, 240–33 Ω, 4–20 mA, 0–5 V | plastic tanks without drilling, up to 2 m depth |
| DFS 24 flow sensor | in the fresh water line | 1000 pulses per litre | pulses | consumption in litres, independent of tank shape |
TGW tube sender: the standard for water
The TGW is fitted from above into a tank opening and delivers a resistance signal of 8 to 180 Ω. It resolves in steps of 16 mm and suits most water tanks with an even cross-section. It is ordered in the length that matches the tank height.
TDN 200 pressure probe: when the tank has an irregular shape
The TDN 200 measures the hydrostatic pressure of the water column, so the tank shape does not matter: it works with 1 cm resolution up to 200 cm tank height and outputs a 4–20 mA signal. The TDS 200 is identical in design but additionally approved for diesel. More in the article TDS and TDN tank probes.
UTV ultrasonic: contact-free from above
The UTV measures by ultrasound from above without touching the water and is intended for fresh water, grey water and holding tanks, not for fuel. Directly below the sender there is a dead zone of 2.5 cm; the UTS 25 spacer ring compensates for it with its 25 mm height. The signal is 0.5–2.5 V. The bore is at least 36 mm, 40 mm with the UFT sound guide tube; the tube improves the measurement when heeling and in waves. This decision is made before drilling. Step by step: Installing the UTV ultrasonic tank sender.
Gobius C: measuring without opening the tank
The Gobius C is bonded to the outside of the tank wall and measures through it. Plastic tanks need no drilling; on metal tanks it sits in the existing 1¼″ flange with a mounting adapter. What matters is the bonding surface: flat, clean, with an even wall thickness and a clear measuring path upwards. It is set up via a Bluetooth app; the maximum tank depth is two metres. Instructions: Mounting the Gobius C from outside.
DFS 24 flow sensor: litres instead of level
The DFS 24 sits in the fresh water line and counts flow rates of 1 to 25 l/min with 1000 pulses per litre. It does not measure the level but the consumption, and it also resolves small draws. For this it needs a starting point after every filling and must sit before any branch. Details: Using the DFS 24 flow sensor.
Display and calibration
TGW, TDN 200 and UTV connect directly to the TCS, VTM 2 and BTM2 tank monitors. These also accept third-party senders with 10–180 Ω, 240–33 Ω or 0–3 V. Values reach the chartplotter via NMEA 2000, for example from the BTM2 or the Gobius C NMEA 2000. In irregularly shaped tanks the level is not proportional to the volume; then calibrate the level in several steps: empty, quarter, half, three quarters and full.
Which method for which water tank?
- Regular tank with an opening on top: TGW if a round gauge is fitted; TDN 200 if it should be more precise.
- Irregular or tall tank: TDN 200, independent of shape, up to 200 cm.
- Plastic tank without access: Gobius C from outside.
- Nothing should go into the water: UTV from above or Gobius C.
- Consumption instead of level: DFS 24 in the line.
To choose step by step: tank sender finder and the overview Tank monitoring on board.
Michael Kögel · Managing Director, philippi elektrische systeme GmbH
Michael Kögel is Managing Director of philippi elektrische systeme GmbH in Remseck am Neckar. Since 1978, the family-owned company has developed and manufactured on-board electrical systems for yachts, motorhomes and special vehicles.
Diplom-Ingenieur (Dipl.-Ing.), electrical engineering, with philippi for more than 35 years. Articles in the philippi Academy are written together with the engineering department and technically reviewed.
Published · Last reviewed
Read more. In the same subject area.
Water consumption instead of fill level: using the DFS 24 flow sensor
The DFS 24 is installed in the fresh water line and counts flow rates of 1 to 25 l/min with 1000 pulses per liter....
5 minReadMounting the Gobius C externally: Adhesive surface, calibration, connection
The Gobius C is glued to the outside of the tank wall and measures through it — without opening the tank. The adhesive surface...
6 minReadTank Probes TDS and TDN: Hydrostatic Measurement for Any Tank Shape
The TDS and TDN tank probes measure the hydrostatic pressure of the liquid column and thus operate independently of the tank shape, with 1...
6 minReadTechnical
Your case isn't covered?
Ask us.
Our team knows every component and usually replies on the same working day, by email or by phone.