Water consumption instead of fill level: using the DFS 24 flow sensor
In short
The DFS 24 is installed in the fresh water line and counts flow rates of 1 to 25 l/min with 1000 pulses per liter. Because it counts liters instead of measuring height, it is independent of the tank shape and also detects small withdrawals. For this, it needs a starting point after each refilling and must be installed before each branching. In the P-bus, the CMT3 tank interface is still required for it.
A level measurement tells you how much is left. A flow measurement tells you how much has been consumed. This sounds like the same information, but it's a different measurement – and often the more accurate one for fresh water tanks.
Counting instead of estimating
The DFS 24 sits in the fresh water line and counts what flows through it. It delivers 1000 pulses per liter with a measuring range of 1 to 25 liters per minute. The monitor then calculates the consumption and the remaining tank content.
The advantage over a level measurement lies in its independence from the tank geometry. A fresh water tank that follows furniture construction and is narrow at the bottom poses difficulties for any height measurement – the flow meter is not concerned with this. It counts liters, and liters are liters.
Added to this is the resolution. A thousand pulses per liter means that even small withdrawals are registered – a height measurement doesn't see this, because the level doesn't move measurably.
What the method cannot do
A flow measurement counts from a starting point. Someone has to set this starting point – typically when filling the tank.
This leads to the only real weakness: if the tank is refilled without resetting the counter, the calculation will diverge. This is the same principle as with ampere-hour counting on the battery – it needs a reference point that the measurement itself cannot provide.
Similarly, the meter does not register what is drawn off past the sensor. A second outlet before the sensor, a drain cock, a line to the deck wash system – all of this falls outside the balance.
NoteTherefore, the sensor should be placed as close as possible to the tank outlet, before any branching. What branches off behind it is counted; what branches off before it is not.
Installation in the line
The sensor has a connection flange for hoses with a diameter of 10–12 mm. A separately available connection flange is available for half-inch hoses.
The housing measures 110 x 23 x 57 mm, the connecting cable is 20 cm long. These 20 cm are the point that is overlooked during planning: the next connection point for the extension must be within this range, or a connection point will be needed in the wet area – which is something to avoid.
Three more points:
- Observe the flow direction. The sensor is directional; installed incorrectly, it will not count correctly.
- Mount accessibly. A water line will eventually be loosened – you'll want to be able to reach that spot then.
- Not at the lowest point. This is where whatever accumulates in a water line collects.
Connection to the display
The sensor can be connected directly to common tank monitors. In the P-Bus system, the connection is made via the CMT3 tank interface – and this is a limitation that should be known: even with a system monitor with an integrated tank interface, the separate CMT3 is still required for the flow sensor.
So, anyone who could manage with four tank senders and therefore wanted to forgo a separate interface must recalculate once a flow sensor is added.
Two sensors for a watermaker
With two flow sensors, a watermaker can be fully balanced: one measures what is produced, the other what is consumed. The difference is the actual change in the tank.
This is the constellation in which flow measurement plays out its greatest advantage – because both directions are recorded and the balance is complete, without the level ever needing to be measured.
Combining both
The two methods are not mutually exclusive, and together they are better than either one alone. The level measurement provides the absolute reference point that the counter needs; the counter provides the resolution that the level measurement lacks.
In practical terms: the level value resets the counter after each filling, and between fillings, the counter provides the more accurate value. This exact interaction also exists with the battery – there, a full charge resets the ampere-hour counting.
Typical errors
- Sensor mounted behind a branch. What branches off before it falls out of the balance.
- Flow direction reversed. The sensor is directional.
- Counter not reset after filling. The calculation will then permanently diverge.
- CMT3 not planned for the P-Bus. It remains necessary for the flow sensor, even with an integrated tank interface.
- 20 cm connection cable overlooked. The next connection point must be within reach.
Michael Kögel · Managing Director, philippi elektrische systeme GmbH
Michael Kögel is Managing Director of philippi elektrische systeme GmbH in Remseck am Neckar. Since 1978, the family-owned company has developed and manufactured on-board electrical systems for yachts, motorhomes and special vehicles.
Diplom-Ingenieur (Dipl.-Ing.), electrical engineering, with philippi for more than 35 years. Articles in the philippi Academy are written together with the engineering department and technically reviewed.
Published · Last reviewed
Related topics
Matching products. Order directly.
Frequently asked questions. Answered briefly.
Where should the flow sensor be located?
As close as possible to the tank outlet and before any branch. Whatever branches off after it is counted; whatever branches off before it drops out of the balance. Nor does the counter record what is drawn past the sensor — a second outlet before the sensor, a drain cock or a line to the deck wash system.
Does flow measurement replace level measurement?
It can, but works better in combination. After each filling, the counter needs an absolute reference point it cannot supply itself — the level measurement provides it. In between, the counter is the more accurate value. If you refill without resetting it, the calculation drifts apart — the same principle as amp-hour counting on a battery.
Do I need a tank interface for the DFS 24 on the P-Bus?
Yes. The sensor can be connected directly to common tank monitors, but in the P-Bus system it is connected via the CMT3 tank interface. This remains necessary even if the system monitor already has an integrated tank interface. Anyone who manages with four tank senders and wanted to skip a separate interface must recalculate.
Read more. In the same subject area.
Measuring the level in a water tank: five methods compared
For fresh water there are five options: the TGW tube sender from above, the TDN 200 pressure probe at the bottom of the tank,...
5 minReadMounting the Gobius C externally: Adhesive surface, calibration, connection
The Gobius C is glued to the outside of the tank wall and measures through it — without opening the tank. The adhesive surface...
6 minReadTank Probes TDS and TDN: Hydrostatic Measurement for Any Tank Shape
The TDS and TDN tank probes measure the hydrostatic pressure of the liquid column and thus operate independently of the tank shape, with 1...
6 minReadTechnical
Your case isn't covered?
Ask us.
Our team knows every component and usually replies on the same working day, by email or by phone.