Tank senders and sensors.
Tank senders and gauges for every tank.
Which tank sender fits depends on the liquid, tank depth, tank material and access. Here you will find TGW and TGT dip-tube senders, TDS and TDN 200 pressure probes, the UTV ultrasonic probe, the TRS 130 black water sender and Gobius sensors that measure through the tank wall, plus tank monitors such as VTM 2 and BTM2, interfaces and fitting accessories for boats, yachts and expedition vehicles.
All products. 28 items.
Tank Probes TDS / TDN 200
from 359,00 €
TGW water tank sender
from 126,70 €
TGT fuel tank sender
from 119,50 €
Tank Monitor 3.5" VTM 2
249,00 €
Battery Tank Monitor BTM2
285,00 €
Ultrasonic tank sender UTV, contactless level measurement
115,00 €
Screw-in Tank Probe TDT-10-250
299,00 €
Tank Sensor Gobius C
389,00 €
Side-Mount Tank Sensor GOBIUS PRO
179,00 €
Tank Monitor 2.4" TCS
179,00 €
Flow sensor DFS 24
135,00 €
Tank sensor for waste water tanks TRS 130
81,90 €
Spacer ring UTS 25
26,90 €
Sound guide tube UFT
from 24,50 €
Universal Tank Interface UTI
89,00 €
Turotest waste tank gauge round 52 mm for ultrasonic tank sender UTV
56,00 €
Turotest tank gauge fuel/water round 52 mm
56,00 €
FAF holding tank monitor
49,00 €
Flange ring with seal GWF / GWW
10,90 €
Float switch DSW
22,90 €
Tank Cap TRV
11,90 €
Float Switch RSW
20,90 €
Gobius C Basic tank sensor
219,00 €
Connection flange DFF 1/2"
4,90 €Tank sensors & tank senders – level measurement for boats, yachts and expedition vehicles
For reliable monitoring of fresh water, waste water, black water and fuel you will find tank senders for every installation situation here – from dip-tube senders, pressure probes and ultrasound to Gobius sensors that measure through the tank wall. Tank senders are also called level senders, level sensors or tank probes – together with a tank gauge or tank monitor they form a tank level monitoring system on board and in the habitation box. Tank monitors, interfaces, flow measurement and installation accessories complete the range. philippi currently stocks 28 products in this category from €4.90 for boats, yachts and expedition vehicles.
In brief: Which tank sender fits depends on the liquid, tank depth, tank material and access. The guide Tank monitoring on board covers the basics, and the tank sender finder names the right sender.
The matching displays, from round gauges to the TCS, VTM 2 and BTM2 tank monitors, are collected under Tank gauges & tank monitors.
Which tank sender for which tank?
| Tank contents | Suitable tank senders | Note |
|---|---|---|
| Fresh water | TGW, UTV, TDS/TDN 200, TDT-10-250, Gobius C | Consumption litre by litre with the DFS 24 flow sensor; for drinking water use the food-grade GWW flange ring |
| Diesel | TGT, TDS 200, TDT-10-250, Gobius C | The TDN 200 is not intended for diesel |
| Petrol | TGT, Gobius C | RSW float switch as a switching contact; TDS/TDN pressure probes not for petrol |
| Waste water | TGW, UTV, TDS/TDN 200, TDT-10-250, Gobius C | UTV with UFT sound guide tube for heel and rough seas |
| Black water | TGW, UTV, TDS/TDN 200, TDT-10-250, Gobius C | 3/4-full alarm under the German black water tank regulation: TRS 130 with FAF alarm panel; UTV with UTS 25 spacer ring |
Tank senders at a glance
TGW and TGT dip-tube senders – water and fuel
The TGW (fresh water, waste water and black water) and TGT (diesel and petrol) dip-tube senders measure with a switching point every 16 mm, deliver a resistance signal of 8–180 Ω and are installed vertically from above. The measuring electronics are galvanically isolated, and the sender can be removed for inspection. The TGT is not intended for black water tanks. Matching accessories: GWA adapter ring for SAE bolt circles, GWF/GWW flange ring and TRV cover cap.
TDS and TDN 200 pressure probes – water, diesel and black water
The probes measure the level via the hydrostatic pressure at the tank bottom, with 1 cm resolution in tanks up to 200 cm high. The TDS 200 is suitable for diesel, water, waste water and black water, the TDN 200 for water, waste water and black water; neither is suitable for petrol. The probe is lowered to the bottom of the tank. The TDT-10-250 is available as a fixed screw-in probe with G1/2″ thread.
UTV ultrasonic probe – contactless from above
The UTV measures the level by ultrasound without contact from above, in ten installation lengths from 20 to 80 cm. It is suitable for fresh water, waste water and black water tanks, but not for fuel (diesel, petrol). There is a dead zone of 2.5 cm below the sensor, which the UTS 25 spacer ring compensates. The UFT sound guide tube improves the measurement when heeling and in waves.
Black water tanks: TRS 130 and FAF
The TRS 130 tank sender reports the 3/4-full state required by the German black water tank regulation, 80 mm below the top of the tank, for tank depths of 200 to 400 mm. The FAF alarm panel shows the alarm visually and audibly, for 12 V or 24 V. The FAF also works with the RSW or DSW float switches.
Gobius – measurement through the tank wall
Gobius sensors measure without contact with the liquid. The Gobius C is mounted on top of the tank, measures continuously with ±2–3 mm in tanks up to 2 m deep and is set up via a Bluetooth app. It is available with analogue outputs, as an NMEA 2000 version and as Basic with a 10–180 Ω output. On plastic tanks it measures through the tank wall; on metal tanks it sits in the existing 1 1/4″ flange with a mounting adapter. The Gobius Pro is mounted on the side, reports via Bluetooth and two switching contacts and is suitable as a full or empty alarm; up to eight sensors can be registered per tank.
Float switches and interface
The RSW float switch (side installation, for oil and petrol) and the DSW (mounted entirely from outside, for low filling pressure) provide a simple switching contact for alarm and warning functions. The UTI universal tank interface converts the 4–20 mA signal of the TDS, TDN and TDT probes for existing analogue round gauges.
DFS 24 flow sensor
Measures fresh water consumption litre by litre in real time, at 1 to 25 l/min; with DFF 1/2" connection flange for 1/2" hoses.
Displays and compatibility
The philippi tank senders TGW, TGT, TDS/TDN, TDT and UTV connect directly to the TCS, VTM 2 and BTM2 tank monitors, as do third-party senders with 10–180 Ω, 240–33 Ω, 0–3 V or 4–20 mA. Volume, tank shape and alarm thresholds can be set for each tank.
| Display | Scope | Feature |
|---|---|---|
| TCS tank monitor | up to 3 tanks, 2 battery voltages | 2.4″ touchscreen |
| VTM 2 tank monitor | up to 4 tanks, 2 battery banks | 3.5″ touchscreen, potential-free relay output |
| BTM2 battery and tank monitor | tank levels plus battery monitor with shunt | 3.5″ touchscreen, NMEA 2000 to the chartplotter |
| PSM3 / PSL system monitors | up to 4 tank senders via the CMT3 P-Bus tank interface | part of the P-BUS onboard network |
| Turotest 52 mm round gauges | one tank per gauge | Fuel/Water for TGT/TGW, Waste for UTV; on 24 V with Rturo series resistor; installed in the TAN 101 panel |
| Chartplotter | via NMEA 2000 | Gobius C NMEA 2000 or BTM2 |
Frequently asked questions. Answered briefly.
Which tank sensor is suitable for black water tanks?
The level in a black water tank is measured by the TGW dip-tube sender, the UTV ultrasonic probe, the TDS and TDN 200 pressure probes, the TDT-10-250 screw-in probe and the Gobius C. The TGT fuel sender is not intended for this. The 3/4-full alarm required by the German black water tank regulation comes from the TRS 130 sender with the FAF alarm panel.
Do I have to drill my tank for installation?
That depends on the sensor type. Dip-tube senders, pressure probes and the UTV ultrasonic probe are installed from above in a tank opening, the TDT-10-250 near the bottom in a G1/2″ thread. The Gobius C measures through the wall of plastic tanks without any drilling. On metal tanks it sits in the existing 1 1/4″ flange with a mounting adapter.
Which sensor measures most accurately?
The TDS and TDN 200 pressure probes measure continuously with 1 cm resolution, the Gobius C with ±2–3 mm. The TGW and TGT dip-tube senders resolve in steps of 16 mm. A level switch such as the Gobius Pro only reports whether the level is above or below the sensor and is suitable as a full or empty alarm.
Which display suits the tank senders?
The philippi tank senders TGW, TGT, TDS/TDN, TDT and UTV connect directly to the TCS, VTM 2 and BTM2 tank monitors. For the PSM3 and PSL P-BUS system monitors, the CMT3 tank interface integrates up to four tank senders. Values reach the chartplotter via NMEA 2000, for example from the BTM2 or the Gobius C NMEA 2000.
How do I find the right tank sender?
Which sender fits depends on the liquid, tank depth, tank material and access. The Academy's tank sender finder asks for these points and names the right sender with length, installation parts and display, plus alternatives. This avoids wrong purchases, such as a float sender for a black water tank.
What does a tank sender do and which signals are there?
A tank sender measures the level in the tank and passes it on to the display as an electrical signal. The philippi TGW and TGT dip-tube senders deliver 8–180 Ω, the TDS, TDN and TDT pressure probes a 4–20 mA signal. The TCS, VTM 2 and BTM2 tank monitors also accept third-party senders with 10–180 Ω, 240–33 Ω or 0–3 V.
Which tank sender is suitable for a diesel tank?
For diesel tanks, the TGT dip-tube sender, the TDS 200 pressure probe, the TDT-10-250 screw-in probe and the Gobius C are suitable. The TDN 200 pressure probe and the UTV ultrasonic probe are not intended for diesel. The level is shown on the Fuel/Water 52 mm round gauge (for the TGT) or on the TCS, VTM 2 and BTM2 tank monitors, which warn at the alarm thresholds you set.
Are the tank senders suitable for an expedition vehicle?
Yes. For fresh water, waste water and diesel tanks in the habitation box, the same senders fit as on board: the TGW and TGT dip-tube senders, the TDS and TDN 200 pressure probes, the UTV ultrasonic probe and the Gobius C, which measures through the wall of plastic tanks without drilling. The display is the TCS, VTM 2 or BTM2 tank monitor.
How can I test a tank sender?
With resistive senders, measure the resistance at the disconnected sender with a multimeter. It must change steadily with the fill level within the characteristic curve, between 8 and 180 Ω for the philippi immersion-tube senders TGW and TGT. The pressure probes TDS, TDN and TDT, by contrast, deliver a 4 to 20 mA current signal, which is measured as current.
What should I do if the tank gauge reads wrong?
First check that sender and gauge match: Europe and the USA use different resistance ranges, otherwise the gauge shows nothing or something wrong. For irregularly shaped tanks, a gauge that can learn a characteristic curve helps, calibrated in the steps empty, quarter, half, three quarters and full. If the sender is faulty, you will find replacements here.