DC Connector 12/24V.
Sockets and plugs for 12/24 V.
In this category you will find sockets, plugs, couplings and cables for 6 to 24 V systems: flush-mount and surface-mount sockets to DIN EN ISO 4165, universal and cigarette-lighter plugs, USB charging sockets and the MagCode magnetic connector system. Most of the range comes from the German manufacturer pro-car, complemented by flush-mount sockets and MagCode components from philippi.
All products. 38 items.
Standard Plug 12V NS 12/24-15
7,05 €
Surface-mounted socket with cover AZS
from 12,50 €
Waterproof Surface-Mount Standard Socket WSD 12/24
25,60 €
Flush-mount socket round with cover ESD 12V round
7,60 €
MagCode Flange Socket MCF
25,50 €
MagCode coupler plug MCS
23,50 €
Analog Panel Mount Socket with Cover ESD Thread
9,30 €
Coupling suitable for 12V standard plug KP 12/24
5,25 €
Angled standard connector NSW
7,50 €
Cigarette lighter plug SUS 12/24-8 A
5,70 €
Cigarette Lighter Plug SUS 12/24-15 A
6,80 €
Universal Plug with Integrated LED USL 12/24-8 A
7,70 €
Angled Cigarette Lighter Plug SWS 12/24-8 A
8,95 €
Universal angled plug with LED UWS 12/24-8 A
13,80 €
Square flush-mounted socket with cover ESD 12V square
7,20 €
Universal plug US 12/24, 8 A / 16 A
from 5,50 €
Cigarette Plug SUS 12/24-7
6,80 €
Panel-mount power socket PSD 12/24, 20 A
from 8,90 €
Surface-mount socket for universal plug AZD 12/24
10,30 €
Built-in triple standard socket DSD 12/24
12,50 €
Twin coupling ZKPZ 12/24
20,20 €
Twin coupling ZKP 12/24
26,70 €
3-gang surface-mounted socket DZD 12/24
31,70 €
Angle-adjustable Dual USB-C/A Charging Plug UWBL 12/24
35,20 €DC connectors 12 V / 24 V – sockets, standard plugs, USB and MagCode for boats, yachts and vehicles
In brief: Standard (DIN) sockets are made for higher currents and a secure fit, cigarette-lighter sockets for compatibility. On board, the standard socket is therefore recommended; universal plugs fit both.
The range at a glance
| Product group | Types | Feature |
|---|---|---|
| Flush-mount standard sockets | ESD 12/24, ESD round, ESD square, ESD thread, ESD MP, DSD (triple) | DIN EN ISO 4165, with cover, up to 16 A |
| Waterproof flush-mount socket | WSD 12/24 | IP 67, screw cap, potted cable |
| Surface-mount sockets | ASD, AZD, AZS, DZD (triple) | mounting without cut-out |
| Power socket | PSD 12/24 | up to 20 A with 2.5 mm² |
| Socket panels | DSR, DSS | PSD and USB combinations, some with switch |
| Plugs | NS, NSW, US, SUS, SWS, USL, UWS | standard, universal and angled plugs |
| USB | UWBL, USB-C charging cable, USB panels | USB-C and USB-A, some with fast charging |
| MagCode | MCF flange socket, MCS coupling plug, cover clip | magnetic, de-energised when disconnected |
| Couplings and cables | KP, ZKP, ZKPZ, KPB, AK, VK, WVK, NSA | extensions, adapters, twin couplings |
Standard sockets and power socket
The ESD flush-mount standard socket is the standard solution for fixed installation: with a cover against dust and spray, for standard and universal plugs, up to 16 A at 6–24 V, connected via 6.3 mm blade terminals. The DSD combines three sockets with 16 A in total. For higher loads such as compressor cool boxes there is the PSD with up to 20 A at 2.5 mm² connection cross-section, and for spray-exposed locations the waterproof WSD to IP 67.
MagCode – magnetic connection
In the MagCode system, plug and flange socket are held together by magnetic force. When disconnected the socket is de-energised, and magnetic coding prevents 12 V and 24 V parts from being mixed up. The connection releases under tension without damaging cable or socket.
| MagCode MCS / MCF | Value |
|---|---|
| Nominal voltage | 12 V or 24 V (coded) |
| Nominal current | 15–16 A |
| Connection cross-section | max. 2.5 mm² |
| Contacts | silver-plated |
| Temperature range | −25 to +85 °C |
| Flange socket | installation depth 22 mm, mounting hole Ø 28 mm |
USB charging from the on-board system
USB charging sockets and panels convert the on-board voltage to 5 V for smartphones, tablets and navigation devices. Models with Power Delivery and Quick Charge charge compatible devices faster; the angled UWBL twin charging plug fits standard and cigarette-lighter sockets. More permanently installed USB sockets can be found in the USB charging sockets category.
Frequently asked questions. Answered briefly.
Which 12 V connector plug should I use?
The standard plug NS 12/24-15 is the first choice: it sits firmly in the standard socket and is rated for up to 15 A. The KP 12/24 coupling is its counterpart on a cable. Universal plugs also fit cigarette-lighter sockets but are usually rated up to 8 A. Outdoors, the WSD 12/24 standard socket is protected to IP 67.
What is the difference between standard and universal plugs?
Standard plugs to DIN EN ISO 4165 have a fixed diameter, only fit standard sockets and are rated for up to 15 A. Universal plugs fit both standard sockets and cigarette lighter sockets, but are usually only approved for up to 8 A. For powerful loads, the standard socket is therefore the better choice.
What does "de-energised when disconnected" mean for MagCode?
When nothing is plugged in, the MagCode flange socket carries no voltage. Only when plug and socket are joined magnetically is the circuit closed. This prevents short circuits caused by touching the contacts, for example with tools or moisture. In addition, magnetic coding prevents 12 V and 24 V parts from being plugged together.
Which socket is suitable for outdoor areas?
For areas exposed to splashing water, the waterproof WSD 12/24 standard socket with screw cap is designed to IP 67. It accepts standard and universal plugs and is supplied with a potted connection cable. The other sockets in this category belong in protected interior areas or behind a cover.
What is the difference between ESD and PSD?
The ESD is a built-in standard socket for standard and universal plugs with up to 16 A. The PSD is a built-in socket for universal plugs with a higher load capacity: 20 A with a 2.5 mm² connection cross-section, 16 A with 1.5 mm². It is suitable for compressor cool boxes, air pumps or inverters with a higher starting current.
Are the connectors suitable for expedition vehicles?
Yes. The sockets and plugs are designed for 6 to 24 V systems and therefore fit the 12 V and 24 V on-board systems of expedition and off-road vehicles. In the living cabin, the standard socket is recommended because of its secure fit; MagCode releases under tension without damaging cable or socket. The USB charging sockets with Power Delivery have E1 approval for vehicle use.
Which 12 V plug types are there?
In 12 V and 24 V on-board systems there are four main plug types: the standard plug to DIN EN ISO 4165 for standard sockets with a secure fit, the cigarette-lighter plug for cigarette-lighter sockets, the universal plug that fits both sockets, and USB charging plugs. In addition there is the magnetic MagCode system, whose coding makes it impossible to mix up 12 V and 24 V parts.