philippi Academy
Setting up the PCU: installation, Connect Hub, tanks, battery values
In short
The PCU is installed in a 140 × 85 mm cut-out; all sensors run via the Connect Hub, from which one cable of up to ten metres leads to the display. First set up the tanks (sensor type, volume, characteristic curve) and the battery (nominal capacity, battery type), then the alarm thresholds. Devices with CI or CAN bus can be operated directly on the display.
This product help collects the guides for the philippi Control Unit PCU: how the display is installed and the Connect Hub wired, how tanks and battery values are set up and how devices are controlled from the PCU via CI and CAN bus. How the PCU works as the hub of the on-board network is explained in the topic area Digital on-board network; the system overview is on the PCU system page.
Installation and wiring
With its frame, the PCU needs a panel cut-out of 140 × 85 mm. The sensor cables do not run individually to the display but via the Connect Hub. It sits close to battery, shunt and tank fittings; from there a single cable of up to ten metres leads to the PCU.
Setting up tanks and battery
For the tank display, enter sensor type, tank height and usable volume and adapt the characteristic curve to the real tank shape; only then set the alarm thresholds. The PCU calculates the state of charge as a running amp-hour balance. For this, every current must flow through the shunt, and the nominal capacity of the bank must be entered correctly: added in parallel, not in series.
Controlling devices and reading the history
Via the CI and CAN interfaces, devices with a bus connection, such as fridge and heater, can be operated directly on the display. If a BullTron battery is connected via the P-Bus, the PCU shows the state of charge of the last 30 days as a curve. Whether a classic battery monitor is enough instead of the PCU is answered by the comparison in this product help.
Michael Kögel · Managing Director, philippi elektrische systeme GmbH
Michael Kögel is Managing Director of philippi elektrische systeme GmbH in Remseck am Neckar. Since 1978, the family-owned company has developed and manufactured on-board electrical systems for yachts, motorhomes and special vehicles.
Diplom-Ingenieur (Dipl.-Ing.), electrical engineering, with philippi for more than 35 years. Articles in the philippi Academy are written together with the engineering department and technically reviewed.
Published · Last reviewed
7 articles
Articles. In this subject area.
Read the state of charge history on the PCU
Die Control Unit PCU zeigt den Ladezustand der letzten 30 Tage als Kurve, wenn eine BullTron-Batterie direkt über den P-Bus eingebunden ist. Entscheidend sind...
5 minReadPCU or classic battery monitor: when each makes sense
A battery monitor answers one question—how's the bank?—and does that well. The PCU additionally answers questions about tank levels and energy flow and controls...
6 minReadControl devices via CI and CAN bus on the PCU
The PCU's integrated CI and CAN interfaces allow bus-connected devices—such as the refrigerator and heater—to be operated directly from the display, including feedback on...
6 minReadBattery values at the PCU: capacity, state of charge, starter battery
The PCU directly measures voltage, current, and temperature, and calculates the state of charge as a running ampere-hour balance. For this, all current must...
7 minReadSetting up tanks on the PCU: Sensor type, volume, characteristic curve
Four steps are necessary for a reliable fuel gauge on the PCU: specify the correct sensor type (resistance 10–180 or 240–33 Ohm, 4–20 mA,...
6 minReadWiring the Connect Hub: which sensor goes where
The Connect Hub belongs where the sensors are — close to the battery, shunt, and tank senders — not near the display. The connections...
6 minReadInstalling the PCU: Cutout, Installation Depth, Initial Commissioning
With frame, the PCU requires a cutout of 140 x 85 mm for a display size of 144 x 90 mm. A suitable installation...
6 minReadRelated topics
Matching products. Order directly.
Related. Related subject areas.
Digital onboard network
P-Bus, NMEA 2000, and Remote Access — Structure, Addressing, Termination, and What to Consider When Integrating Third-Party Devices.
ReadMeasure and Monitor
Shunts, tank senders, and monitors — which readings are reliable, which are not, and how to detect a measurement error.
ReadProduct help P-Bus
Wiring, choosing monitor and shunt, tanks, relay modules and NMEA 2000: the guides for the philippi P-Bus.
ReadTechnical
Your case isn't covered?
Ask us.
Our team knows every component and usually replies on the same working day, by email or by phone.