philippi P-Bus battery management shunt SHX 348 – precise current and capacity measurement
philippi · Onboard monitoring
P-Bus Battery Management Shunt SHX 348
The P-Bus Battery Management Shunt SHX 348 from philippi is a digital shunt for the P-BUS on-board electrical system of yachts, boats and off-road vehicles. It is installed in the battery's negative line and measures current, voltage and capacity over the entire range from 10 mA to 300 A with ±0.5% accuracy — the basis of any reliable battery monitoring.
In detail. P-Bus Battery Management Shunt SHX 348.
- Detects quiescent currents from 10 mA, revealing creeping consumers that drain a bank over weeks
- ±0.5% accuracy over the entire measuring range — not just in the upper part
- Measures starter battery voltage directly, without a second shunt
- Measures battery temperature directly at the shunt using the TEMP-BT temperature sensor
- Galvanically isolated P-BUS connection — battery banks separated from the on-board system can also be monitored
Resolution and accuracy: the real difference.
A shunt is only as good as its smallest reliably measurable current. The philippi SHX 348 starts at 10 mA — and that is precisely where hard-to-find problems sit. A forgotten device with a 30 mA quiescent current draws about 0.7 amp-hours per day and five per week. A shunt that only evaluates from just under one ampere sees none of this; the bank is still empty.
The second half is the accuracy of ±0.5%, over the entire measuring range — from milliamp quiescent current to the inverter's start-up current. This is what makes an amp-hour balance correct over several days: in a state-of-charge display, measurement errors add up because every reading goes into a running calculation. A shunt that is only accurate at high currents produces a display that slowly drifts in standby.
Starter battery and temperature — without a second shunt.
The starter battery voltage can be measured directly at the SHX 348; no second shunt is needed. This covers the most common fault: a starter battery that has not been recharged for weeks because the isolation relay or DC-DC charger no longer works. A second shunt is only needed if a complete current balance with state of charge is also wanted for the second bank.
The battery temperature is also measured directly at the shunt: the TEMP-BT temperature sensor is connected to the SHX 348, and the temperature appears on the system monitor in addition to current, voltage and capacity. A separate temperature interface is not required.
Installation and connection.
The philippi SHX 348 is installed in the battery's negative line and continuously reports its values to the P-BUS network; from current and voltage it calculates the current battery capacity, shown in colour in the battery symbol of the system monitor. Power is supplied via the existing voltage measuring line — no additional supply cable is needed. The power connection is via an M8 stud, the P-BUS connection via an M12 connector.
For systems with higher currents or powerful loads, the identical but more powerful SHX 648 is available.
Compatibility.
The SHX 348 works with the P-BUS system monitors PSM3, PSL and PSL Plus and all other P-BUS components of the philippi on-board system. For temperature measurement, the TEMP-BT sensor is connected directly to the shunt. If the yield of a charging source or the consumption of an individual device is also to be recorded, the SHX 300-L energy shunt completes the system.
Original equipment quality
- Individually tested: every unit is connected and tested in a test environment in Remseck.
- Brand-name components, as in series production for boatyards.
- Repairable for decades: spare parts up to 30 years back, own repair centre.
Technical data
| Parameter | Value |
|---|---|
| Current rating | Continuous 300 A (600 A for 1 min, 1500 A for 0.5 s) |
| Measuring range | 10 mA – 300 A |
| Accuracy | ±0.5% over the entire measuring range |
| Current draw | 20 mA (5 mA in sleep mode) |
| Operating voltage | 8–32 V |
| Connection | M8 stud, P-BUS via M12 |
| Temperature measurement | Directly at the shunt via TEMP-BT temperature sensor |
| Dimensions | L 118 x W 40 x H 65 mm |
| Article no. | 0 7100 0348 |
Manual
Read the manual onlineManufacturer and product safety
philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Germany
info@philippi-online.de
Safety information: see the operating manual and data sheet.
Frequently asked questions. Answered briefly.
How accurately does the SHX 348 measure?
The SHX 348 measures with ±0.5% accuracy over the entire range from 10 mA to 300 A. Both matter: the fine lower limit that makes quiescent currents visible, and consistent accuracy across all currents. Without it, a state-of-charge display drifts over days, because every measurement error adds up in the running balance.
Why does measuring from 10 mA matter?
Because quiescent currents are exactly this size. A forgotten device drawing 30 mA takes about 0.7 amp-hours a day from the battery and around five per week. A shunt that only evaluates from just under one ampere sees none of this. The SHX 348 makes such creeping consumers visible before the bank is empty.
Do I need a second shunt for the starter battery?
No. The starter battery voltage can be measured directly at the SHX 348. This shows you, for example, when a starter battery has not been recharged for weeks because the isolation relay or DC-DC charger has failed. A second shunt is only needed if you also want a complete current balance with state of charge for the second bank.
Can I also measure the battery temperature?
Yes. The TEMP-BT temperature sensor is connected directly to the SHX 348; no separate temperature interface is needed. The temperature appears on the P-BUS system monitor, such as the PSM3, in addition to current, voltage and capacity. No separate supply cable is needed either, as the shunt is powered via the existing voltage measuring line.
Can I monitor a battery that is isolated from the on-board system?
Yes. The P-BUS connection of the SHX 348 is galvanically isolated. This allows you to monitor battery banks that are separated from the rest of the on-board system, for example an emergency battery for radio equipment. The shunt handles 300 A continuous current, and briefly 600 A for one minute and 1500 A for 0.5 seconds.