Battery shunt SHE 348 for BTM2, BLS and BLM2, LIN bus
5,0 out of 5 · 1 reviewThe SHE 348 battery shunt (LIN bus, battery management) from philippi is installed in the negative line of the consumer battery and provides the basic current measurement for philippi battery monitors. It detects charging and discharging currents from 10 mA with ±0.5% accuracy at a continuous current of up to 300 A — suitable for battery capacities up to 50,000 Ah.
In detail. Battery shunt SHE 348 for BTM2, BLS and BLM2, LIN bus.
- Provides the basic current measurement for philippi monitors BTM2, BLS, and BLM2 — no battery monitoring without SHE 348
- Detects quiescent currents from 10 mA, making creeping consumers visible
- ±0.5% accuracy across the entire measuring range, not just at high currents
- Measure starter battery voltage directly, without a second shunt
- Detect battery temperature directly at the shunt via the TEMP-BT temperature sensor
Resolution and Accuracy: why both matter
The philippi SHE 348 measures from 10 mA — and it is precisely in this range that currents lie that can silently drain a battery bank. A device with a quiescent current of 30 mA draws approximately 0.7 ampere-hours from the battery per day and five per week. A shunt that only measures from around one ampere upwards will not detect this — the bank will still be empty, and the cause will remain undiscoverable.
The second half is the accuracy of ±0.5% across the entire measuring range. The state of charge is not a momentary measurement, but a continuous ampere-hour balance: every single measured value contributes to an ongoing calculation, and measurement errors accumulate over days. Only consistent accuracy across the entire range ensures that the display still matches reality after two weeks.
Starter Battery and Temperature — without a second shunt
The starter battery voltage can be measured directly at the SHE 348 — a second shunt is not necessary for this. This covers the most practically important case: early detection that the starter battery has not been recharged for weeks, for example, because isolation relays or charge converters are no longer working. A second shunt is only needed if a complete current balance with state of charge is also desired for the second bank.
Similarly, the battery temperature is measured directly at the shunt: the TEMP-BT temperature sensor is connected to the SHE 348, and the temperature appears on the monitor in addition to current, voltage, and capacity. A separate temperature interface is not required for this. This is more than just a display: the usable capacity depends on the temperature, and for LiFePO4, charging below freezing is the point at which damage occurs.
Easy Connection
Power is supplied via the voltage measurement line of the consumer battery, and connection is made via M8 bolts. Developed and manufactured in Germany.
Compatibility
The SHE 348 is the basic current measurement for philippi battery monitors BTM2, BLS and BLM2, as well as for the Series 200 switch panels with integrated BTM2 (STV 232, STV 234-2p, STV 236, STV 238, STV 244) and for STV 314 (BLS-Set). The SHE 348 is already included in the BLS-Set and BLM2-Set; it is available separately for retrofitting. For temperature measurement, the TEMP-BT sensor is connected directly to the shunt. If an additional energy source, such as a solar system, is also to be monitored, the SHP 348 energy shunt is used in addition.
Original equipment quality
- Individually tested: every unit is connected and tested in a test environment in Remseck.
- Brand-name components, as in series production for boatyards.
- Repairable for decades: spare parts up to 30 years back, own repair centre.
Technical data
| Feature | Value |
|---|---|
| Article number | 070030348 |
| Current carrying capacity | Continuous current 300 A (600 A for 1 min, 1500 A for 0.5 s) |
| Measuring range | 10 mA – 300 A |
| Accuracy | ±0.5% across the entire measuring range |
| Current consumption | 10 mA at 12 V, 5 mA at 24 V |
| Operating voltage | DC 8–40 V |
| Connection | Bolt M8 |
| Temperature measurement | directly at the shunt via TEMP-BT temperature sensor |
| Battery capacity | up to 50,000 Ah |
| Dimensions | L 118 × W 40 × H 65 mm |
Manufacturer and product safety
philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Germany
info@philippi-online.de
Safety information: see the operating manual and data sheet.
Reviews. Unfiltered, via Judge.me.
5.0 out of 5
1 review on Judge.me
- 5 ★ 1
- 4 ★ 0
- 3 ★ 0
- 2 ★ 0
- 1 ★ 0
-
Easy to install. It would be nice to have a cover also to protect it
Antti Airasmaa · Verified purchase ·
Frequently asked questions. Answered briefly.
How accurately does the SHE 348 measure?
The SHE 348 measures with ±0.5% accuracy over the entire measuring range, starting at 10 mA, at a continuous charge or discharge current of up to 300 A. Briefly, it withstands 600 A for one minute and 1500 A for 0.5 seconds. Because measurement errors add up in the running amp-hour balance, consistent accuracy across the whole range matters.
Why does measuring from 10 mA matter?
Because quiescent currents are exactly this size. A device drawing 30 mA takes about 0.7 amp-hours a day from the battery and around five per week. A shunt that only evaluates from just under one ampere sees none of this. The SHE 348 makes such creeping consumers visible before the bank is empty.
Do I need a second shunt for the starter battery?
No. The starter battery voltage can be measured directly at the SHE 348, as can the battery temperature via the TEMP-BT temperature sensor, without a separate interface. A second shunt is only needed if you also want a complete current balance with state of charge for the second bank.
Which monitors does the SHE 348 work with?
The SHE 348 is the basic current measurement for the philippi BTM2, BLS and BLM2 battery monitors and for the 200 series switch panels with integrated BTM2 and the STV 314 with BLS set. It is already included with the BLS set and BLM2 set and is available separately for retrofitting.
How is the shunt connected?
The SHE 348 is installed in the negative line of the house battery via M8 terminal studs. Power is supplied via the voltage measuring line, so no separate supply cable is needed. It operates on DC 8–40 V, draws 10 mA at 12 V and is suitable for battery capacities up to 50,000 Ah.
Goes well with it. Accessories and add-ons.
Prefer a quick chat?
Tell us what you are planning. We will tell you honestly what you need and what you don’t.