philippi Academy

Setting up the P-Bus: wiring, monitor, shunt, tanks

By Michael KögelLast reviewed

In short

The P-Bus is laid as a line with M12 cables, T-connectors and exactly two terminators. Choose the system monitor by cut-out size, number of tank senders and system voltage, and the shunt by the relevant current: SHX 348 up to 300 A, SHX 648 up to 600 A. NMEA 2000 is only coupled via the CBN bridge.

This product help collects the guides for the philippi P-Bus: how the network is wired, which system monitor and which shunt fit, how tanks and relay modules are integrated and how the P-Bus works with NMEA 2000 and BullTron batteries. The basics of the bus system are covered in the topic area Digital on-board network.

Wiring

The P-Bus is laid as a line: M12 cables, T-connectors and exactly two terminators. NMEA 2000 is not connected directly but only coupled via the CBN bridge. It separates both networks and transfers selected data; what appears on screen is ultimately decided by the chart plotter.

Choosing monitor and shunt

The choice between PSM3, PSL and PSL Plus depends on cut-out size, number of tank senders and system voltage, not on display size. For the shunt, the relevant current decides: SHX 348 for 300 A with M8 terminal, SHX 648 for 600 A with M16. Both resolve from 10 mA and measure the starter battery without a second shunt.

Integrating tanks, relays and main switch

Tanks run via the CMT3; four parameters are set on the monitor for each tank, and irregularly shaped tanks are compensated via the characteristic curve. For switched loads there are five CMR relay modules (411, 412, 431, 811 and 232), which differ in channel count, current per channel, number of poles and dimming function. The battery main switch is controlled remotely by TSC and FBR 500: 260 A with the TSC alone, 500 A together with the FBR 500.

BullTron batteries on the P-Bus

A BullTron battery is converted once for operation on the P-Bus: with two apps, one setting and a firmware update. After that it reports its values to the bus itself.

· Managing Director, philippi elektrische systeme GmbH

Michael Kögel is Managing Director of philippi elektrische systeme GmbH in Remseck am Neckar. Since 1978, the family-owned company has developed and manufactured on-board electrical systems for yachts, motorhomes and special vehicles.

Diplom-Ingenieur (Dipl.-Ing.), electrical engineering, with philippi for more than 35 years. Articles in the philippi Academy are written together with the engineering department and technically reviewed.

Published · Last reviewed

8 articles

Articles. In this subject area.

Setting up a BullTron battery for the P-Bus

Die Umstellung einer BullTron-Batterie auf den P-Bus dauert rund 15 Minuten und braucht nur ein Smartphone mit Bluetooth: In der App SMART BMS wird...

6 minRead

PSM3, PSL, or PSL Plus: Choosing the Right System Monitor

All three monitors show the same P-Bus data and are configured directly on the device without a computer. The PSM3 has a 3.5-inch display,...

6 minRead

Wiring the P-Bus: M12 cable, T-connectors, terminators

The P-Bus is wired as a line: a continuous M12 main line with T-pieces from which short stub lines lead to the devices. A...

6 minRead

Connecting P-Bus and NMEA 2000: Correctly Installing the CBN Bridge

P-Bus and NMEA 2000 must not be connected directly — the P-Bus is not NMEA-2000 certified for safety reasons. Connection is exclusively via the...

5 minRead

Remote control of the main switch: Correctly combining TSC and FBR 500

The TSC main switch interface controls the external battery disconnect switch FBR 500 via the P-Bus or an external control button and includes adjustable...

6 minRead

CMR Relay Modules in Comparison: 411, 412, 431, 811, and 232

CMR 411 S: 4 channels, 10 A, single-pole, with dimmer. CMR 412 S: same, double-pole. CMR 811 S: 8 channels, 10 A, single-pole, with...

6 minRead

Integrating tanks via the CMT3: Sensor types and characteristics

The CMT3 integrates up to four tank sensors into the P-Bus and understands resistance sensors (10–180 ohms, 240–33 ohms, or freely configurable 0–300 ohms),...

6 minRead

SHX 348 or SHX 648: determining the appropriate shunt

The crucial factor is the highest current through the measuring point, not the size of the battery bank. The SHX 348 carries 300 A...

6 minRead

Technical

Your case isn't covered?
Ask us.

Our team knows every component and usually replies on the same working day, by email or by phone.

philippi tote bag and catalogue