In detail. Automatic changeover LAU 340 F with RCBO 40 A/30 mA, 3 sources.

  • Switches with a delay and only once the source voltage is stable, protecting generator and loads
  • Isolates the sources on all poles, two sources never feed in at the same time
  • Additional output circuit can switch off charger or water heater in inverter mode
  • Built-in RCBO, room for ACW current transformer

Original equipment quality

  • Individually tested: every unit is connected and tested in a test environment in Remseck.
  • Brand-name components, as in series production for boatyards.
  • Repairable for decades: spare parts up to 30 years back, own repair centre.
How we manufacture

Technical data

FeatureValue
Rated voltage230 V / 50 Hz
Input 1 / 216 A / 16 A
Input 3 (generator)40 A (9 kW)
Output 1 / 240 A / 16 A
RCBO40 A / 30 mA
ProtectionIP X4
Dimensions (W × H × D)335 × 270 × 145 mm
P-BUSyes, via ACE-T cable (5 0411 1161)
Item no.011003401
UseBoat, yacht, expedition and off-road vehicle

Manufacturer and product safety

philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Germany
info@philippi-online.de

Safety information: see the operating manual and data sheet.

Frequently asked questions. Answered briefly.

Which sources does the LAU 340 F switch between?

Automatically between shore power, inverter and generator; it selects the available source itself.

How much generator power can the LAU 340 F handle?

Up to 40 A, i.e. 9 kW.

What is the difference between LAU 340 F and LAU 340?

The F version has a built-in RCBO and room for an ACW current transformer; without F the RCBO must be provided separately.

Can the LAU 340 F be connected to the P-BUS system?

Yes, via the ACE-T cable (item no. 5 0411 1161). The PSM or PSL system monitor then shows the active source and voltage and lets you set the changeover delay and voltage limits.

Is the LAU 340 F suitable for an expedition vehicle?

Yes. In the living cabin it switches automatically between shore power, inverter and generator as soon as a source fails or the shore power plug is pulled. For vehicles with living quarters DIN VDE 0100-721 applies; installation by a qualified electrician.