The Philippi Shore Power Unit LAE 100 is a shore power unit for 230 V/50 Hz mains power connection on board, which indicates correct connection via mains indicator lights and is suitable for yachts with fully encapsulated installation without additional cover.
- Immediately signals whether the shore power connection is correctly established via mains indicator lights
- Fully encapsulated housing made of self-extinguishing plastic reliably protects against contact
- Simple, secure connection via rear feed-through terminals without additional installation work
- Manufactured according to EN ISO 13297 with VDE-tested components – suitable for boat registration
The LAE 100 takes over the 230 V shore power and immediately makes its correct connection visible via mains indicator lights. The supply lines are connected at the rear via feed-through terminals; the fully encapsulated housing made of self-extinguishing plastic protects against contact and makes an additional cover unnecessary. An integrated RCD/MCB (RCBO, 16 A / 0.03 A, 2-pole) secures the shore power connection.
Philippi manufactures the LAE 100 according to EN ISO 13297 with VDE-tested and approved components; a confirmation, which may be required for the final inspection of the electrical system, is included with every delivery.
| Feature | Value |
|---|---|
| Mains power connection | 230 V / 50 Hz |
| Circuit breaker | RCD/MCB RCBO 16 A / 0.03 A, 2-pole |
| Connection | Feed-through terminals, rear |
| Housing | Self-extinguishing plastic, encapsulated |
| Dimensions (W x H x D) | 150 x 185 x 100 mm |
| Cut-out dimension | 125 x 160 mm |
| Standard | EN ISO 13297, VDE-tested components |
| SKU | 010001003 |
Compatibility: If you also need a 230 V Schuko socket on board, the Philippi LAE 101 from the same series is the right alternative.
Frequently Asked Questions
Is the LAE 100 suitable for boat registration?
It is manufactured according to EN ISO 13297 and contains VDE-tested and approved components; a confirmation that may be required for the final acceptance is included with the delivery.
How is the LAE 100 connected?
The connection is made at the rear via feed-through terminals.
What protection does the built-in circuit breaker offer?
An RCD/MCB (RCBO, 16 A / 0.03 A, 2-pole) secures the shore power connection.
Order now and integrate the shore power connection into your onboard electrical system safely and in compliance with standards.
⚠️Safety data sheet can be found under Downloads!
Downloads
Deutsche Downloads
Englische Downloads