E-T-A circuit breaker 3130 for STV200 series: black rocker with red LED, two-pole, AC 230 V
E-T-A · Power distribution
Circuit breaker for Series STV200, double-pole AC 230 V, red LED
The E-T-A circuit breaker 3130 for the philippi Series STV200 is a double-pole thermal overcurrent circuit breaker with rocker for AC 230 V / 50 Hz. It protects a circuit against overload, switches it on and off and shows the switching state via a red LED. Available with 6 A, 10 A, 16 A and 20 A.
- Re-engage without changing the fuse
- Thermal release for miniature circuit breakers
In detail. Circuit breaker for Series STV200, double-pole AC 230 V, red LED.
- Switching state at a glance thanks to the integrated red LED
- Double-pole version for safe AC 230 V switching in the on-board system
- Can be switched back on after tripping, no fuse change needed
- Low LED current consumption of 0.7 mA at 230 V
For DC 12 and 24 V the same series offers the double-pole circuit breaker with green LED. Complete 230 V panels of the Series 200 can be found under AC switch panels.
Technical data
| Feature | Value |
|---|---|
| Version | Double-pole, thermal, with red LED |
| Voltage | AC 230 V / 50 Hz |
| LED current consumption | 0.7 mA at 230 V |
| Mounting cut-out | 26.3 x 34.2 mm |
| Device width | 29.5 mm |
| 6 A | 3130-F12B-S2T1-W24AR7-6A, order no. 1 3130 5006 |
| 10 A | 3130-F12B-S2T1-W24AR7-10A, order no. 1 3130 5010 |
| 16 A | 3130-F12B-S2T1-W24AR7-16A, order no. 1 3130 5016 |
| 20 A | 3130-F15B-L7T1-W24AR7-20A, order no. 1 3130 5020 |
Manufacturer and product safety
E-T-A Elektrotechnische Apparate GmbH
Industriestraße 2-8
90518 Altdorf
Germany
info@e-t-a.de
Safety information: see the operating manual and data sheet.
Frequently asked questions. Answered briefly.
Which mounting cut-out does the circuit breaker need?
The mounting cut-out is 26.3 x 34.2 mm, the device width 29.5 mm. This fits the grid of the philippi Series STV200. Which current rating you choose depends on the load and the conductor cross-section of the circuit: 6, 10, 16 or 20 A.
How much current does the LED draw?
The red LED draws only 0.7 mA at 230 V and shows whether the circuit is switched on. The indicator therefore hardly loads the on-board system. This breaker is not intended for 12 and 24 V DC circuits; for those the same series offers the version with green LED.
Goes well with it. Accessories and add-ons.
Prefer a quick chat?
Tell us what you are planning. We will tell you honestly what you need and what you don’t.