philippi automatic changeover switch for shore, generator and inverter with RCBO LAU 325 F
philippi · Changeover switches for shore power, generator and inverter
Automatic changeover LAU 325 F with RCBO 25 A/30 mA, 3 sources
The philippi LAU 325 F is an automatic changeover for three 230 V sources: shore power, inverter and generator. The generator input is rated 25 A (6 kW), shore power and inverter 16 A each. An RCBO 25 A / 30 mA is built in.
- For safe shore power connection
In detail. Automatic changeover LAU 325 F with RCBO 25 A/30 mA, 3 sources.
- Switches with a delay and only once the source voltage is stable, protecting generator and loads
- Isolates the sources on all poles, two sources never feed in at the same time
- Additional output circuit can switch off charger or water heater in inverter mode
- Built-in RCBO, room for ACW current transformer
Original equipment quality
- Individually tested: every unit is connected and tested in a test environment in Remseck.
- Brand-name components, as in series production for boatyards.
- Repairable for decades: spare parts up to 30 years back, own repair centre.
Technical data
| Feature | Value |
|---|---|
| Rated voltage | 230 V / 50 Hz |
| Input 1 / 2 | 16 A / 16 A |
| Input 3 (generator) | 25 A (6 kW) |
| Output 1 / 2 | 25 A / 16 A |
| RCBO | 25 A / 30 mA |
| Protection | IP X4 |
| Dimensions (W × H × D) | 266 × 200 × 115 mm |
| P-BUS | yes, via ACE-T cable (5 0411 1161) |
| Item no. | 011003251 |
| Use | Boat, yacht, expedition and off-road vehicle |
Manufacturer and product safety
philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Germany
info@philippi-online.de
Safety information: see the operating manual and data sheet.
Frequently asked questions. Answered briefly.
Which sources does the LAU 325 F switch between?
Automatically between shore power, inverter and generator; it selects the available source itself.
How much generator power can the LAU 325 F handle?
Up to 25 A, i.e. 6 kW. For up to 9 kW there is the LAU 340.
What is the difference between LAU 325 F and LAU 325?
The F version has a built-in RCBO and room for an ACW current transformer; without F the RCBO must be provided separately.
Can the LAU 325 F be connected to the P-BUS system?
Yes, via the ACE-T cable (item no. 5 0411 1161). The PSM or PSL system monitor then shows the active source and voltage and lets you set the changeover delay and voltage limits.
Is the LAU 325 F suitable for an expedition vehicle?
Yes. In the living cabin it switches automatically between shore power, inverter and generator as soon as a source fails or the shore power plug is pulled. For vehicles with living quarters DIN VDE 0100-721 applies; installation by a qualified electrician.