In detail. Shore power connection unit LAE 234 LGK for combination inverters.

  • Secure combination of shore power, generator, and inverter in one panel
  • Automatic consumer isolation when switching to inverter operation
  • Four separately fused 230 V circuits for various onboard consumers
  • Monitoring of shore power and onboard voltage via integrated indicator lights and voltmeter

The LAE 234 LGK combines shore power connection, generator feed, and a combi inverter in one unit, automatically switching between the sources. The integrated shore/generator changeover switch (25 A) isolates defined consumers during inverter operation to prevent the inverter from being overloaded. An RCBO protective switch (32 A / 30 mA) protects the entire unit, while three AC mains indicator lights and a 230 V voltmeter display the status of the shore power. Four two-pole thermal circuit breakers (10 A, 230 V / 50 Hz) distribute power to individual consumer circuits.

Connection is via rear terminals; the electrical design is back-of-hand safe for protection against electric shock. The panel must be installed so that the rear is only accessible with tools and is covered. If the feed point is more than 3 m away, the supply line near it must be additionally protected with an MCB circuit breaker (e.g., philippi LAE 205). The scope of delivery includes a labeling set SKZ for boats and black mounting screws; a set for vehicles (SKZ-MOBIL) is available on request.

The LAE 234 LGK is compatible with the philippi Series 200 circuit distribution panels and can be supplemented with upstream MCB circuit breakers like the LAE 205 for longer supply lines.

Original equipment quality

  • Individually tested: every unit is connected and tested in a test environment in Remseck.
  • Brand-name components, as in series production for boatyards.
  • Repairable for decades: spare parts up to 30 years back, own repair centre.
How we manufacture

Technical data

Feature Value
Circuit breaker RCBO 32 A / 30 mA
Output circuits 4 x two-pole thermal circuit breaker, 10 A
Voltage AC 230 V / 50 Hz
Indicators 3 AC mains indicator lights, voltmeter 230 V
Generator power up to 6 kW (more powerful version on request)
Connection rear terminals, back-of-hand safe
Dimensions (W x H x D) 210 x 210 x 110 mm
Installation cutout 186 x 186 mm (12 mm smaller per edge than the panel)
Scope of delivery Labeling set SKZ (boats), black mounting screws

Manufacturer and product safety

philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Deutschland
info@philippi-online.de

Safety information: see the operating manual and data sheet.

Frequently asked questions. Answered briefly.

What is the shore/generator changeover switch of the LAE 234 LGK needed for?

It switches between shore power and generator feed and provides integrated consumer isolation during inverter operation, allowing a combi inverter to be safely integrated.

What generator power is the LAE 234 LGK designed for?

The unit is suitable for AC generators up to 6 kW; a more powerful version is available on request.

Is additional protection necessary if the distance to the feed point is greater?

If the distance to the feed point is more than 3 m, the supply line near it must be additionally protected with an MCB circuit breaker (e.g., LAE 205).

How large must the installation cutout for the LAE 234 LGK be?

The installation cutout can be chosen 12 mm smaller per edge than the panel dimensions (W 210 x H 210 mm), i.e., 186 x 186 mm.

Goes well with it. Accessories and add-ons.

philippi Landanschluss Leitungsschutzschalter LAE 205
philippi

Shore Power Circuit Breaker LAE 205

94,00 €
philippi Automatische Umschalter + Wechselrichter LAU 325
philippi

Automatic Transfer Switches + Inverter LAU 325

549,00 €
philippi Landanschlusseinheit LAE 233
philippi

Shore power unit LAE 233

138,00 €

Prefer a quick chat?

Tell us what you are planning. We will tell you honestly what you need and what you don’t.

Beratung bei philippi in Remseck am Neckar