Manual LAE 101: Connecting and Installing the Shore Power Unit.

The LAE 101 shore power unit protects and monitors the 230 V shore power connection on board. A mains indicator light shows the connection to the AC supply on shore (ready for operation), and an RCBO 16 A residual current circuit breaker with 30 mA protects the loads. The connection is made via feed-through terminals on the underside of the housing. This page summarises the connection, installation dimensions and technical data from the installation manual.

Manual edition: V1B, June 2017, bilingual German and English, 4 pages.

This manual applies to both the LAE 100 and the LAE 101. For the sister variant, see the manual for the LAE 100.

Intended use and safety

The LAE 100 and LAE 101 shore power units are used to protect and monitor the 230 V shore power connection. The mains indicator light shows the connection to the AC supply on shore (ready for operation). The electrical connection is made via the feed-through terminals on the underside of the housing.

  • Make all connections to the shore power unit carefully and use the supplied wire end ferrules when connecting.
  • Work on system components for 230 V/50 Hz mains voltage may only be carried out by qualified electricians.
  • The installation manual is part of the component delivery. Keep it in a safe place for later maintenance work and pass it on to any subsequent owners.

General information on AC products: Safety instructions for 230 V AC products (PDF, German).

Connection and wiring diagram

Wiring diagram of the LAE 101 shore power unit: rear view with terminals PE, 11, 12 for shore power and PE, 41, 42 for loads

Rear view from the manual: on the left the terminals PE, 42, 41 for the general loads, on the right PE, 12, 11 for the shore power connection, each with a 3 × 2.5 mm² cable. Minimum cable cross-section 2.5 mm².

Section Terminal Connection
Mains input, 230 V / 50 Hz 11 L1 (phase) of the shore power
12 N (neutral) of the shore power
PE PE (protective earth) of the shore power
Output, protected by RCBO 16 A (30 mA) 41 L1 (phase) of the loads
42 N (neutral) of the loads
PE PE (protective earth) of the loads

Technical data

Supply voltage 230 volts / 50 Hz AC
Protection RCBO 16 A, 30 mA (Swiss CH version: RCBO 13 A, 30 mA)
Mounting cut-out LAE 101 160 × 125 mm, minimum depth 97 mm
Mounting cut-out LAE 100 125 × 160 mm
Cable cross-section minimum 2.5 mm²

Conformity and disposal

According to the manual, the product meets the requirements of the EU directives 2004/108/EC (electromagnetic compatibility, immunity EN 61000-6-1, emission EN 61000-6-3) and 2006/95/EC (electrical equipment designed for use within certain voltage limits). For disposal, local regulations apply; use the collection points for waste electrical and electronic equipment.

Also suitable: LAE 100 · LAE 113 with indicator lights and three outputs · Shore power on board: connecting, protecting and switching safely · Standards for onboard electrical systems