The Philippi Two-Channel Deep Discharge Protector TSD 40 is a remote-controlled protection device for 12/24 V onboard power systems. It protects the battery from harmful deep discharge by disconnecting consumers in two stages instead of all at once.
- Safety-relevant consumers remain active, while luxury consumers are disconnected first when battery voltage drops
- An acoustic pre-alarm warns in good time before the impending disconnection
- Usable as energy management with the "13 V" setting to switch on a cool box, heated carpet, or hot water boiler when sufficient charging power is available
- With the optional remote control panel FB-TSA, both outputs can be switched remotely and re-enabled briefly in an emergency
Conventional deep discharge protection devices completely disconnect all connected consumers as soon as the battery's lower voltage limit is reached. The Philippi TSD 40 takes a more differentiated approach in the onboard power system: via two independently adjustable channels, it first disconnects only non-safety-relevant luxury consumers, while important consumers continue to operate. Reconnection occurs automatically at 12.5 V (or 25 V for 24 V operation) as soon as the battery is sufficiently recharged.
| Feature | Value |
|---|---|
| Operating voltage | 12 / 24 V DC, adjustable via DIP switch |
| Switching capacity | max. 40 A per channel (2) |
| Cut-off voltage Rel. 1 | 11.8 / 12.0 / 12.2 / 13 V @300 s (DIP switch, double values for 24 V) |
| Cut-off voltage Rel. 2 | 10.8 / 11.2 V @50 s (DIP switch, double values for 24 V) |
| Reconnect voltage | 12.5 V (for 24 V: 25 V) |
| Self-consumption | 1.3 mA / 12 V, 2 mA / 24 V |
| Connection | Screw terminals, max. 10 mm² |
| Dimensions | L 130 x W 80 x H 42 mm |
| SKU | 080001240 |
Compatibility: The TSD 40 can be combined with the FB-TSA remote control panel for remote switching of both outputs.
What distinguishes the TSD 40 from a simple deep discharge protector?
It does not switch off all consumers at once, but rather disconnects only luxury consumers first via two channels, while safety-relevant consumers can continue to operate.
How does reconnection occur?
Automatically, as soon as the battery voltage reaches 12.5 V (or 25 V for 24 V).
Can I be warned before disconnection?
Yes, an acoustic alarm warns of the impending disconnection of the respective stage.
Order now and reliably protect your onboard batteries from deep discharge.
⚠️Safety data sheet can be found under Downloads!