philippi cam switch CA 63 D 926 shore/generator/inverter
philippi · Changeover switches for shore power, generator and inverter
Cam switch CA 63 D 926 shore/generator/inverter with charger cut-out, 63 A
The philippi CA 63 D 926 cam switch changes over manually between shore power, generator and inverter (1-0-2-3), up to 63 A. In inverter mode it disconnects the charger so the inverter does not drain its own battery through the charger.
- German Industrial Quality
In detail. Cam switch CA 63 D 926 shore/generator/inverter with charger cut-out, 63 A.
- Three sources, up to 63 A
- Charger cut-out in inverter mode
- 64 × 64 mm front
For up to 25 A there is the CH 16 D 926.
Original equipment quality
- Individually tested: every unit is connected and tested in a test environment in Remseck.
- Brand-name components, as in series production for boatyards.
- Repairable for decades: spare parts up to 30 years back, own repair centre.
Technical data
| Feature | Value |
|---|---|
| Function | Changeover 1-0-2-3 shore/generator/inverter, charger cut-out |
| Current rating | 63 A |
| Front / mounting depth | 64 × 64 mm / 81 mm |
| Max. panel thickness | 5 mm (thicker: LEER CA blank plate) |
| Item no. | 640427980 |
| Use | Boat, yacht, expedition and off-road vehicle |
Manufacturer and product safety
philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Germany
info@philippi-online.de
Safety information: see the operating manual and data sheet.
Frequently asked questions. Answered briefly.
Why is the charger disconnected in inverter mode?
Otherwise the inverter would supply the charger with 230 V, which in turn charges the same battery that feeds the inverter. That only wastes energy and can drain the battery.
What does Wandler mean?
Wandler is the inverter that produces 230 V from the on-board battery. The switch selects whether shore power, generator or inverter supplies the 230 V system.
Does the CA 63 D 926 fit the switchboard of an expedition vehicle?
Yes. It is mounted from the front into the panel and suits 230 V systems in the living cabin, for example switching between shore power and inverter. For panels thicker than 5 mm use the LEER CA blank plate.
Goes well with it. Accessories and add-ons.
Prefer a quick chat?
Tell us what you are planning. We will tell you honestly what you need and what you don’t.