Tank Monitoring
- Featured
- Most relevant
- Best selling
- Alphabetically, A-Z
- Alphabetically, Z-A
- Price, low to high
- Price, high to low
- Date, old to new
- Date, new to old
philippi
Tank Monitor 3.5" VTM 2
philippi
Battery Tank Monitor BTM2
philippi
Tank Probes TDS / TDN 200
philippi
Screw-in Tank Probe TDT-10-250
philippi
Universal Tank Interface UTI
philippi
Water tank sender for TGW
philippi
Fuel level sensor for TGT
philippi
Non-Contact Level Measurement UTV
philippi
Sound guide tube UFT
Gobius
Side-Mount Tank Sensor GOBIUS PRO
Gobius
Tank Sensor Gobius C NMEA 2000
philippi
Wastewater tank monitoring FAF
philippi
Tank sensor for waste water tanks TRS 130
philippi
Flange ring with seal GWF / GWW
Turotest
Round Measuring Instrument for UTV Waste UTV
Turotest
Round Measuring Instrument Fuel / Water 52mm
philippi
Panel with Rocker Switch TAN 101
Tank Monitoring
Tank sensors & tank senders – level measurement for boats, yachts and motorhomes
For reliable monitoring of fresh water, waste water, black water and fuel you will find tank senders for every installation situation here – from dip-tube senders, pressure probes and ultrasound to Gobius sensors that measure through the tank wall. Tank monitors, interfaces, flow measurement and installation accessories complete the range.
In brief: Which tank sender fits depends on the liquid, tank depth, tank material and access. The guide Tank monitoring on board covers the basics, and the tank sender finder names the right sender.
The matching displays, from round gauges to the TCS, VTM 2 and BTM2 tank monitors, are collected under Tank gauges & tank monitors.
Which tank sender for which tank?
| Tank contents | Suitable tank senders | Note |
|---|---|---|
| Fresh water | TGW, TDS/TDN 200, TDT-10-250, Gobius C | Consumption litre by litre with the DFS 24 flow sensor; for drinking water use the food-grade GWW flange ring |
| Diesel | TGT, TDS 200, TDT-10-250, Gobius C | The TDN 200 is not intended for diesel |
| Petrol | TGT, Gobius C | RSW float switch as a switching contact; TDS/TDN pressure probes not for petrol |
| Waste water | UTV, TDS/TDN 200, TDT-10-250, Gobius C | UTV with UFT sound guide tube for heel and rough seas |
| Black water | UTV, TDS/TDN 200, TDT-10-250, Gobius C | 3/4-full alarm under the German black water tank regulation: TRS 130 with FAF alarm panel; UTV with UTS 25 spacer ring |
Tank senders at a glance
TGW and TGT dip-tube senders – water and fuel
The TGW (water) and TGT (diesel and petrol) dip-tube senders measure with a switching point every 16 mm, deliver a resistance signal of 8–180 Ω and are installed vertically from above. The measuring electronics are galvanically isolated, and the sender can be removed for inspection. They are not intended for black water tanks. Matching accessories: GWA adapter ring for SAE bolt circles, GWF/GWW flange ring and TRV cover cap.
TDS and TDN 200 pressure probes – water, diesel and black water
The probes measure the level via the hydrostatic pressure at the tank bottom, with 1 cm resolution in tanks up to 200 cm high. The TDS 200 is suitable for diesel, water, waste water and black water, the TDN 200 for water, waste water and black water; neither is suitable for petrol. The probe is lowered to the bottom of the tank. The TDT-10-250 is available as a fixed screw-in probe with G1/2″ thread.
UTV ultrasonic probe – contactless from above
The UTV measures the level by ultrasound without contact from above, in ten installation lengths from 20 to 80 cm. It is intended for waste and black water tanks; for water and fuel philippi recommends other senders. There is a dead zone of 2.5 cm below the sensor, which the UTS 25 spacer ring compensates. The UFT sound guide tube improves the measurement when heeling and in waves.
Black water tanks: TRS 130 and FAF
The TRS 130 tank sender reports the 3/4-full state required by the German black water tank regulation, 80 mm below the top of the tank, for tank depths of 200 to 400 mm. The FAF alarm panel shows the alarm visually and audibly, for 12 V or 24 V. The FAF also works with the RSW or DSW float switches.
Gobius – measurement through the tank wall
Gobius sensors measure without contact with the liquid. The Gobius C is mounted on top of the tank, measures continuously with ±2–3 mm in tanks up to 2 m deep and is set up via a Bluetooth app. It is available with analogue outputs, as an NMEA 2000 version and as Basic with a 10–180 Ω output. On plastic tanks it measures through the tank wall; on metal tanks it sits in the existing 1 1/4″ flange with a mounting adapter. The Gobius Pro is mounted on the side, reports via Bluetooth and two switching contacts and is suitable as a full or empty alarm; up to eight sensors can be registered per tank.
Float switches and interface
The RSW float switch (side installation, for oil and petrol) and the DSW (mounted entirely from outside, for low filling pressure) provide a simple switching contact for alarm and warning functions. The UTI universal tank interface converts the 4–20 mA signal of the TDS, TDN and TDT probes for existing analogue round gauges.
DFS 24 flow sensor
Measures fresh water consumption litre by litre in real time, at 1 to 25 l/min; with DFF 1/2" connection flange for 1/2" hoses.
Displays and compatibility
The philippi tank senders TGW, TGT, TDS/TDN, TDT and UTV connect directly to the TCS, VTM 2 and BTM2 tank monitors, as do third-party senders with 10–180 Ω, 240–33 Ω, 0–3 V or 4–20 mA. Volume, tank shape and alarm thresholds can be set for each tank.
| Display | Scope | Feature |
|---|---|---|
| TCS tank monitor | up to 3 tanks, 2 battery voltages | 2.4″ touchscreen |
| VTM 2 tank monitor | up to 4 tanks, 2 battery banks | 3.5″ touchscreen, potential-free relay output |
| BTM2 battery and tank monitor | tank levels plus battery monitor with shunt | 3.5″ touchscreen, NMEA 2000 to the chartplotter |
| PSM3 / PSL system monitors | up to 4 tank senders via the CMT3 P-Bus tank interface | part of the P-BUS onboard network |
| Turotest 52 mm round gauges | one tank per gauge | Fuel/Water for TGT/TGW, Waste for UTV; on 24 V with Rturo series resistor; installed in the TAN 101 panel |
| Chartplotter | via NMEA 2000 | Gobius C NMEA 2000 or BTM2 |
Frequently asked questions about tank sensors
Which tank sensor is suitable for black water tanks?
The TGW and TGT dip-tube senders are not intended for black water tanks. The level is measured by the UTV ultrasonic probe, the TDS and TDN 200 pressure probes, the TDT-10-250 screw-in probe and the Gobius C. The 3/4-full alarm required by the German black water tank regulation comes from the TRS 130 sender with the FAF alarm panel.
Do I have to drill my tank for installation?
That depends on the sensor type. Dip-tube senders, pressure probes and the UTV ultrasonic probe are installed from above in a tank opening, the TDT-10-250 near the bottom in a G1/2″ thread. The Gobius C measures through the wall of plastic tanks without any drilling. On metal tanks it sits in the existing 1 1/4″ flange with a mounting adapter.
Which sensor measures most accurately?
The TDS and TDN 200 pressure probes measure continuously with 1 cm resolution, the Gobius C with ±2–3 mm. The TGW and TGT dip-tube senders resolve in steps of 16 mm. A level switch such as the Gobius Pro only reports whether the level is above or below the sensor and is suitable as a full or empty alarm.
Which display suits the tank senders?
The philippi tank senders TGW, TGT, TDS/TDN, TDT and UTV connect directly to the TCS, VTM 2 and BTM2 tank monitors. For the PSM3 and PSL P-BUS system monitors, the CMT3 tank interface integrates up to four tank senders. Values reach the chartplotter via NMEA 2000, for example from the BTM2 or the Gobius C NMEA 2000.
How do I find the right tank sender?
Which sender fits depends on the liquid, tank depth, tank material and access. The Academy's tank sender finder asks for these points and names the right sender with length, installation parts and display, plus alternatives. This avoids wrong purchases, such as a float sender for a black water tank.