Set alarm thresholds appropriately

6 Min Lesezeit
Kurz beantwortet

Four to six thresholds suffice: low state of charge, low voltage, high voltage, battery temperature, and optionally black water tank and fresh water. The threshold for the state of charge is about 50 percent for lead-acid and about 20 percent for LiFePO4. Without delay and without hysteresis, every alarm will flap and be switched off.

An alarm has exactly one purpose: to trigger an action that would otherwise come too late. Every warning that no one can or needs to react to reduces the effectiveness of all others. Therefore, the most important decision is not where a threshold lies, but which thresholds exist at all.

Which alarms are really needed

A useful set comprises four to six thresholds. More will not be read.