BTM2 Manual: Installing and Setting Up the Battery-Tank Monitor.

The BTM2 battery-tank monitor shows the state of charge, currents and voltage of the main battery, the voltage of up to two further batteries and the levels of up to four tanks on a touch display. It works with the SHE 348 shunt on DC 12–48 V and, if required, passes the values on to the chartplotter via NMEA 2000. This page summarises installation, settings and technical data from the manual.

Manual edition: Rev. 1B, February 2023, software version 1.x.

Scope of delivery and accessories

Included: BTM2 battery-tank monitor, 3 plug-in terminals (2× MVSTB 2.5 3-pin, 1× 9-pin), 2 ASH1 fuse holders with FSS 1A fuse and the manual.

Optional accessories Purpose Order no.
Shunt SHE 348 Battery capacity monitoring 0 7003 0348
Shunt SHP 348 Solar current measurement 0 7003 0351
Temperature sensor Temp-BT 3480 Battery temperature (display only) 0 5900
Interface ACE-LIN Connection of an ACE series charger 0 8000 4975
N2K cable Connection to NMEA 2000 5 0411 1140

Recommended tank senders (not included): TGW dip-tube sender for fresh water and TGT for fuel, UTV ultrasonic sensor for waste tanks, DFS flow sensor (fresh water only) and, for deep tanks up to 200 cm, the TDS 200 and TDN 200 pressure sensors. Sensors from other manufacturers can also be connected. The tank sender finder shows which sender suits your tank.

Note from the manual: only with the DFS flow sensor is the litre display exact, because it actually measures litres. With all other sensors the measured level is converted into litres.

Installation and connection

Location: The BTM2 is designed for yachts and is suitable for enclosed spaces only, protected from rain, moisture, dust and condensation. Do not install it outdoors or in areas with a risk of explosion. Connection must be carried out by qualified electricians only; disconnect the battery supply leads beforehand and observe correct polarity.

Monitor

  • Panel cut-out 85 × 85 mm, minimum mounting depth 35 mm, at a protected, dry and clearly visible location.
  • On the back: 3-pin terminal for power supply and the communication line (LIN bus) to the SHE and SHP shunts, 9-pin terminal for the tank senders, 2-pin terminal for the potential-free relay contact.
  • The monitor's power supply may be interrupted at any time. The battery data are retained because they are stored in the SHE 348 shunt.
  • The LIN bus connection to the shunt is a single-core cable of 1 to 1.5 mm².

SHE 348 shunt (battery monitoring)

  • Mount it as close as possible to the service battery, protected and dry, without contact to the positive terminal.
  • The shunt sits in the negative path: connect the B− side with a short, thick cable (35–70 mm²) to the negative terminal of the main battery. With several batteries connected in parallel, their common negative terminal goes to B−.
  • All loads, charging sources and the negative terminals of the starter batteries belong on the V− side, ideally via a ground busbar. No other cable may be connected between B− and the battery negative terminal, otherwise not all currents are recorded.
  • The shunt's sense lead goes via an inline fuse holder (1 A) to the positive terminal of the main battery. It measures the voltage and powers the shunt.
  • The shunt should stay permanently connected to the battery. With the monitor switched off it goes into sleep mode at 2 mA. If the system stays uncharged for more than 3 months, disconnect the shunt from the battery.
Connection on the SHE shunt (5-pin) Function
1 (+1) Voltage measurement of the main battery and power supply of the shunt, mandatory
2 (+2) Optional: voltage of a second battery bank (e.g. starter battery)
3 (T−, T+) Optional: Temp-BT temperature sensor (T− brown, T+ blue wire), on the outside of the battery case
4 (L) LIN bus to the monitor and to the ACE charger
LED on the shunt Meaning
Fast flashing Shunt firmware update in progress
Flash every second Normal operation
Flash every 5 seconds Sleep mode (monitor off)

SHP 348 shunt (solar current)

Optional, in the negative path of the solar system, as close as possible to the battery. The negative terminal of the solar system goes to the V− side. On the 5-pin connector: terminal 1 (+1) for measurement and supply, terminal 4 for the LIN bus to the monitor (preferably 1 mm²).

ACE charger (ACE-LIN interface)

To communicate with a charger of the ACE series, the ACE-LIN interface is fitted in the charger; with the ACE 12/60 and ACE 24/30 it replaces the integrated monitor. Disconnect the charger from the mains beforehand. The charging curve can only be set on the monitor if the charger's DIP switches are set to ABCD = "1111".

Tank senders

  • Up to four tanks; the first sender goes to TG 1, further ones in sequence.
  • Resistive senders (e.g. TGT, TGW) and active senders (e.g. TDS pressure probe) may be connected in any mix.
  • Connect a DFS flow sensor only to the DFS terminals; TG 1 then stays free, since DFS can only be enabled for tank 1.
  • If an ultrasonic sensor is powered directly from the vessel's electrical system rather than via the BTM2, its supply lead must be fused with 1 A.
  • The negative leads of the tank senders belong on the monitor's negative terminal, to avoid measurement errors.

Wiring diagram

Wiring diagram of the BTM2 battery-tank monitor with SHE 348 shunt, SHP shunt, tank senders and NMEA 2000 cable

Overview from the manual: monitor with tank sender terminal, relay (IN/NO/NC), NMEA 2000 output and microSD slot; SHE shunt between the service battery (B−) and the vessel's electrical system (V−); SHP shunt for the solar system; sense leads each fused with 1 A.

Settings and commissioning

The settings menu opens via the gear icon at the bottom centre of the main screen. The PIN is 1234 when delivered. Submenus: Display, Battery, Charger, Energy source, Tanks and Alarms.

During commissioning, set the following in the Battery menu:

Setting Note from the manual
Nominal capacity 1–9999 Ah. Set only with the battery 100 % charged, as this sets the display to 100 % and all counters to 0.
Nominal voltage 12, 24, 36 or 48 V
Battery type GEL, WET, AGM, Lithium or INDIV, for detecting "full" and "empty"
Ah efficiency (CEF) Factory setting 95 %, adapts automatically over the last 4 cycles. If it falls below 70 %, the battery has reached the end of its life.
Cycle depth The discharge from which a charge cycle is counted: starter batteries 10–20 %, GEL batteries up to 50 %
Peukert exponent Typically 1.27 for lead, 1.02 for lithium; normally do not change
Name, Name 2, Name 3 Battery names shown on the display

If the battery was not full at commissioning, it must be fully charged so that the display synchronises with the state of charge.

Alarms

Alarms are shown on the display and can also be output visually (backlight flashes), audibly (internal buzzer) and via the potential-free relay contact (max. 1 A). The visual and audible alarms can be acknowledged by touching the screen or switched off automatically after 0–255 s.

Alarm Setting range
Battery 1: capacity alarm 10–80 %, factory setting 50 %
Battery 1: battery empty / deep discharge 20 % / 0 %, fixed by the battery management
Battery 1: overvoltage 14–60 V
Battery 1: overtemperature 40–60 °C
Battery 2 and 3: undervoltage / overvoltage 9–24 V / 14–32 V, must be adjusted for 24 V batteries
Tank 1–4 0 % off, 1–50 % empty alarm, 51–99 % full alarm, each delayed by 15 s

Setting up and calibrating tank senders

The tank menu opens via the arrow button next to the relevant tank. There you set the tank type (water, diesel, petrol, waste, grey water), volume in litres and sensor type. Selectable sensor types: TGX 10–180 Ω, 240–33 Ω, User R, User U, UTV 40/80, TDx, DFS, DFS+, TRS/RSW/DSW and Gobius 4.

Calibration (mandatory for User R, User U and TDS), three ways:

  1. Filling in steps: With the tank empty, read the measured value and enter it at 0 %, then repeat at 25, 50, 75 and 100 % fill. This gives the correct content even with an unusual tank shape.
  2. With the tank full (e.g. TDS 200): Enter the measured value with the probe outside the tank at 0 %, and after installation at 100 %. Divide the difference by 4 and add it step by step to obtain 25, 50 and 75 %.
  3. Values known: Enter the values for 0, 25, 50, 75 and 100 % directly.

More on choosing and installing senders: Level measurement on the boat.

NMEA 2000

The N2K cable is required for the connection: 4-pin connector on the monitor, Micro-C connector (M12) into the network via a T-piece. The monitor needs its own power supply. After switching on, it sends every 2.5 seconds:

  • Tank levels: PGN 127505 (Fluid Level)
  • Battery data: PGN 127508 (Battery Status) and PGN 127506 (DC Detailed Status)

Each tank and each battery needs a unique instance in the network. The instances are set in the setup: for the monitor under Display, for the tanks under Tanks, for the batteries under Battery. With two philippi devices in the network, the device instances must be different. With Raymarine plotters the instances must start at 0.

Software update

  1. Copy the update file to an empty microSD card (FAT32), without folders, in the top level.
  2. Insert the card into the slot on the back of the monitor and disconnect the power supply.
  3. Switch the power supply back on. The monitor detects the new software, installs it automatically and shows the progress.

If the monitor starts normally, no card was detected or the software is already up to date. The SHE and SHP shunts can also be updated via the monitor (file PB99R1 on the card, briefly de-energise the shunt and plug it back in within 30 seconds).

Troubleshooting

  • "Not synchronised" does not disappear despite full charge (U above 14.0 V and current below 2 % of nominal capacity): Change the nominal capacity by 1 Ah, then the monitor synchronises manually.
  • Battery-full detection does not work: Check the charging voltage of the charger and solar system and set the battery type to WET in order to work with the lowest values.
  • In both cases check: Each charging source individually; with the loads switched off, the charging current must be shown as positive. Only the shunt with its B− terminal may be connected to the battery's negative terminal, nothing else.

Technical data

Supply voltage DC 8–60 V
Monitor current consumption 60 mA at maximum brightness, 5 mA in sleep mode
Shunt current consumption 20 mA, 2 mA in sleep mode
Shunt 348 0.1 mΩ, M8 stud connections
Measuring range U1 / U2 0–60 V / 0–35 V, resolution 30 mV, accuracy 0.25 %
Current measuring range −600 to +600 A, accuracy 0.5 %
Shunt current rating 300 A continuous, 600 A for 1 min, 1500 A for 0.5 s
Relay potential-free, max. 1 A
Temperature measurement (external sensor) −15 to 60 °C, accuracy 1 K
Monitor dimensions 105 × 105 × 40 mm
Shunt dimensions 118 × 40 × 65 mm
Conformity EMC Directive 2014/30/EC, EN 61000-6-1, EN 61000-6-3

Warranty: two years from the date of purchase. For questions about installation or for a repair: Contact · Warranty and repair