DIGITAL SWITCHING AND CONTROL VIA PSM AND PSL
The new relay module allows for the fused switching of 4 loads, up to a maximum of 10A, via the integrated fuse or circuit breaker. Potential-free switching is also possible. The respective channel can also be switched via a button using the digital switching input on the CMR.
Integrated Emergency Operation:
Each output channel can be bypassed by repositioning the fuse or circuit breaker. This means that every circuit can be operated manually in the event of a system failure. The protection provided by the circuit breaker or fuse is maintained.
Delivery includes M12-T cable. Requires PSL from version 1.3.0 and PSM2 from version 8B
CMR 411 (fuse) / CMR 411S (with circuit breakers)
Switching channels: 4 (1-pole)
Current load per channel: 10 A
Inputs: 4
Additional function: 4 PWM dimmers
Dimensions: B 140 x L 120 x H 50 mm
⚠️Safety data sheet can be found under Downloads!
FAQ
Ja dies ist möglich. Dafür muss bei der Bestellung der Schalttafel die benötigte Sicherungsgröße pro Stromkreis angegeben werden.
Ja vor jede Schalttafel muss eine Hauptsicherung in die Zuleitung zur Schalttafel nahe der Batterie integriert werden.
Ja, es können alle im Marine und Fahrzeugbereich üblichen Geber angeschlossen werden.