Imported a boat from the USA?
Converting a boat from the USA to 230 V.
We plan the conversion and supply the parts.
If you import a boat from the USA, it comes with an on-board system for 120 V and 60 Hz, usually with a 30 A or 50 A shore connection. On a European pontoon you get 230 V and 50 Hz from a CEE socket. Three ways lead there: an isolation transformer down to 120 V, conversion to 230 V or a mixed solution. philippi in Remseck, Germany, plans the conversion and supplies the parts.
3 ways Isolation transformer, conversion to 230 V or mixed solution.
ISO 13297 AC installations planned to the standard.
Mastervolt Pro Distributor and service partner.
Advice: +49 7146 8744-0, directly from Remseck.
What differs. USA and Europe compared.
| Feature | US boat | Europe |
|---|---|---|
| Voltage | 120 V; 50 A inlets often 120/240 V | 230 V |
| Frequency | 60 Hz | 50 Hz |
| Shore connection | 30 A or 50 A, US locking plug | usually 16 A, blue CEE plug |
| Wire colours | black, white, green | brown, blue, green-yellow |
| Standard for on-board electrics | ABYC E-11 | EN ISO 13297 |
A 30 A connection at 120 V provides about 3.6 kW, a European 16 A connection at 230 V about 3.7 kW. The power at the pontoon stays similar. Boats with a 50 A inlet often need a 32 A shore connection in Europe.
Three ways. To European shore power.
| Option | What you need | Advantage | Limit |
|---|---|---|---|
| 1. Keep the 120 V system | European shore inlet and multi-tap isolation transformer (230 V in, 120 V out), e.g. Mastervolt IVET-D, 3.5 kW | Little intervention, US appliances stay, galvanic isolation included | Frequency stays 50 Hz; transformer weighs 23 kg |
| 2. Convert to 230 V/50 Hz | CEE shore inlet, shore power unit with RCBO, 230 V AC panel, 230 V appliances | Fits every European marina, spare parts everywhere | More work, appliances are replaced |
| 3. Mixed solution | 230 V system for the large loads, small transformer for individual 120 V appliances | Expensive US appliances stay, the rest is European | Two voltages on board, clear labelling needed |
Which way suits your boat? That depends on the rating plates, the shore connection and how often you are at a European pontoon. Send us photos and we will tell you: request a conversion.
The 60 Hz question. What the transformer cannot do.
An isolation transformer changes the voltage, not the frequency. Victron also points this out explicitly for its isolation transformers. On a European pontoon you therefore always have 50 Hz.
- Critical: appliances with a motor, compressor or timer rated for 60 Hz only, such as air conditioning, refrigeration or microwave.
- Not critical: appliances marked “50/60 Hz” on the rating plate.
- Chargers: electronic units with a wide-range input run on both grids, for example the philippi ACE battery charger with 90 to 265 V and 47 to 65 Hz.
Free initial assessment
Photos are enough. We tell you which way suits you.
Photograph the rating plates, shore connection and panel and send the request. We will get back to you with a proposal for your boat.
The parts. From one source.
Checklist. Before the conversion.
- Photograph the rating plates of all AC appliances: voltage, frequency, current.
- Note the shore connection: 30 A or 50 A, 120 V or 120/240 V, plus generator and inverter with model.
- Photograph the AC panel and distribution, collect existing wiring diagrams.
- Choose the way: isolation transformer, conversion to 230 V or mixed solution.
- Plan protection: 30 mA residual current device and galvanic isolation with a galvanic isolator or isolation transformer.
- Have the conversion carried out and tested by a qualified electrician.
The photos from steps 1 to 3 are enough for a first proposal: request now.
CE and inspection. What belongs to an import.
If the boat has no CE marking, in Germany the private importer must ensure under Section 11 of the 10th ProdSV, before first use, that it meets the requirements of the Recreational Craft Directive 2013/53/EU. This post-construction assessment is carried out by a notified body, which also checks the electrical installation. EN ISO 13297 applies to AC installations on recreational craft.
In Switzerland, ESTI requires an acceptance inspection before first commissioning, including for boats from abroad. Clarify customs and import VAT with customs or your tax adviser. This is not legal advice.
A clean plan with a wiring diagram helps when the electrics are inspected. We supply it: request a conversion.
Request a conversion
Your US boat. Our proposal.
In four short steps. We will get back to you with a proposal for the way and the parts.
Or call us: +49 7146 8744-0
Frequently asked questions. On US boats in Europe.
Can I connect an American boat to shore power in Europe?
Not directly. The pontoon supplies 230 V and 50 Hz via a CEE plug, while the on-board system of a US boat is built for 120 V and 60 Hz. You either need an isolation transformer that converts 230 V to 120 V, or you convert the AC system to 230 V. Both belong in the hands of a qualified electrician.
Is an isolation transformer enough to switch a US boat to European shore power?
For the voltage yes, for the frequency no. An isolation transformer such as the Mastervolt IVET-D Multi-Tap turns 230 V back into 120 V, but the frequency stays 50 Hz. Check the rating plates to see whether air conditioning, refrigerator, microwave and other appliances with a motor or compressor are rated for 50 Hz or 50/60 Hz.
Which appliances do I have to replace when converting to 230 V?
Everything permanently connected to the AC system and built for 120 V only: shore plug and inlet, AC panel, often the charger or inverter/charger, the water heater element, air conditioning and galley appliances. Chargers with a wide-range input, such as the philippi ACE with 90 to 265 V, work on both grids. Cable cross-sections can often be reused; checking them is part of the planning.
Does an imported US boat have to be inspected in Germany?
If the boat has no CE marking, the private importer must ensure under Section 11 of the 10th ProdSV, before first use, that it meets the requirements of the Recreational Craft Directive 2013/53/EU. The post-construction assessment is carried out by a notified body, which also checks the electrics. Clarify the scope with the body before the conversion; this is not legal advice.
Advice
Rather talk right away? We are here for you in Remseck.
Isolation transformer or conversion to 230 V: we work out with you what your boat needs.