Manual LAE 111: Connecting and Installing the Shore Power/Generator Changeover Unit.
The LAE 111 shore power changeover unit protects the 230 V connection, switches between shore power and generator or between shore power and inverter, and monitors the connection. Two mains indicator lights show the AC connection, and a voltmeter (250 V) shows the onboard voltage. Four double-pole circuit breakers rated 10 A switch the individual loads. This page summarises the connection, installation dimensions and technical data from the installation manual.
Intended use and safety
The LAE 111 shore power changeover unit is used to protect, switch and monitor the 230 V connection (shore power/generator or shore power/inverter). Two mains indicator lights show the AC connection, and the voltmeter (250 V) shows the onboard voltage. The four double-pole circuit breakers (10 A) can be used to switch the individual loads. The electrical connection is made via feed-through terminals on the underside of the housing.
- Work on system components for 230 V/50 Hz mains voltage may only be carried out by qualified electricians.
- The installation manual is part of the component delivery. Keep it in a safe place for later maintenance work and pass it on to any subsequent owners.
General information on AC products: Safety instructions for 230 V AC products (PDF, German).
Connection and wiring diagram

Rear view from the manual, from left to right: Air Condition (PE, 62, 61), Sockets (PE, 52, 51), Battery Charger (PE, 42, 41), Hot Water (PE, 32, 31), generator/inverter (PE, 22, 21) and shore power (PE, 12, 11). Cables: 3 × 4 mm² for shore power and generator/inverter, at least 3 × 1.5 mm² for the four outputs.
| Section | Terminals | Connection |
|---|---|---|
| Mains input, shore power, 230 V / 50 Hz (4 mm²) | 11 / 12 / PE | L1 (phase), N (neutral), PE (protective earth) of the shore power |
| Mains input, onboard source, 230 V / 50 Hz (4 mm²) | 21 / 22 / PE | L1, N, PE of the generator or inverter |
| Output A "Hot Water", 10 A (min. 1.5 mm²) | 31 / 32 / PE | L1, N, PE of the water heater |
| Output B "Battery Charger", 10 A (min. 1.5 mm²) | 41 / 42 / PE | L1, N, PE of the charger |
| Output C "Sockets", 10 A (min. 1.5 mm²) | 51 / 52 / PE | L1, N, PE of the sockets |
| Output D "Air Condition", 10 A (min. 1.5 mm²) | 61 / 62 / PE | L1, N, PE of the air conditioning |
All outputs are protected by the RCBo 25 A (30 mA) residual current circuit breaker.
Technical data
| Supply voltage | 230 volts / 50 Hz AC |
| Protection | RCBo 25 A, 30 mA |
| Outputs A, B, C and D | Overcurrent circuit breaker 10 A; RCBO 30 mA |
| Dimensions | W 260 × H 185 × D 100 mm |
| Mounting cut-out | W 235 × H 160 mm, minimum depth 97 mm |
Conformity and disposal
According to the manual, the product meets the requirements of the EU directives 2004/108/EC (electromagnetic compatibility, immunity EN 61000-6-1, emission EN 61000-6-3) and 2006/95/EC (electrical equipment designed for use within certain voltage limits). For disposal, local regulations apply; use the collection points for waste electrical and electronic equipment.
Also suitable: LAE 113 · LAE 100 · Shore power on board: connecting, protecting and switching safely · Generating energy on board: alternator, solar, shore power
For questions about installation or for a repair: Contact · Warranty and repair · All manuals