philippi P-Bus AC interface CAV
philippi · Onboard monitoring
P-Bus AC Interface CAV
The P-Bus AC-Interface CAV is a DIN rail housing interface that measures a 230 V/50 Hz AC phase and feeds energy data from charging sources and consumers into the P-BUS on-board network – for yachts and vehicles with digital energy monitoring.
- Land connection in sight
- Easy installation without a computer
In detail. P-Bus AC Interface CAV.
- Makes AC sources and AC consumers without their own P-BUS connection visible (e.g., Studer X-Tender, Mastervolt or Victron devices via an additional interface)
- Supplies on-board network voltage, on-board network current, and consumed kilowatt-hours directly to the system monitor
- Freely nameable, so that each source or consumer remains uniquely identifiable
- Measurement range extendable from 16 A to up to 100 A via external transducer
Many on-board systems consist of components from different manufacturers that already supply their own energy data – such as philippi chargers of the ACE series or shore power transfer units LAU, which already provide their AC data in a P-BUS-compatible manner. For all other 230 V sources and consumers without their own P-BUS interface, the AC-Interface CAV is installed and set to the respective device.
The philippi CAV records the current and voltage of the connected 230 V AC devices and provides the P-BUS with the on-board network voltage, the on-board network current, and the kilowatt-hours consumed since the last reset. The electrical connection is made via screw terminals, and the connection to the P-BUS is made via an M12 T-cable included in the scope of delivery.
Compatible with all P-BUS systems based on philippi system monitors PSM3 or PSL. For currents over 16 A, the external transducer WAC is additionally used.
Original equipment quality
- Individually tested: every unit is connected and tested in a test environment in Remseck.
- Brand-name components, as in series production for boatyards.
- Repairable for decades: spare parts up to 30 years back, own repair centre.
Technical data
| Parameter | Value |
|---|---|
| Measured Phase | 230 V / 50 Hz, 1-phase |
| Current Measurement Range | 16 A (internal shunt), up to 100 A with external transducer WAC |
| AC Connection | Screw terminals |
| P-BUS Connection | M12 T-cable (included) |
| Dimensions | L 76 x W 53 x H 46 mm |
| Item No. | 0 7100 0230 |
Manufacturer and product safety
philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Germany
info@philippi-online.de
Safety information: see the operating manual and data sheet.
Frequently asked questions. Answered briefly.
For which on-board network voltage is the AC-Interface CAV suitable?
For an AC phase with 230 V / 50 Hz.
Do I need the CAV if I already own ACE series chargers or an LAU shore power transfer unit?
No, these devices already provide their AC data directly in a P-BUS-compatible manner. The CAV is installed for power sources and consumers that do not have their own P-BUS connection option, such as Studer X-Tender or Mastervolt devices via an additional interface.
How can I measure currents over 16 A?
The measurement range of the CAV can be extended to up to 100 A via the external transducer WAC.
Goes well with it. Accessories and add-ons.
Prefer a quick chat?
Tell us what you are planning. We will tell you honestly what you need and what you don’t.