In detail. P-Bus AC Interface CAV.

  • Makes AC sources and AC consumers without their own P-BUS connection visible (e.g., Studer X-Tender, Mastervolt or Victron devices via an additional interface)
  • Supplies on-board network voltage, on-board network current, and consumed kilowatt-hours directly to the system monitor
  • Freely nameable, so that each source or consumer remains uniquely identifiable
  • Measurement range extendable from 16 A to up to 100 A via external transducer

Many on-board systems consist of components from different manufacturers that already supply their own energy data – such as philippi chargers of the ACE series or shore power transfer units LAU, which already provide their AC data in a P-BUS-compatible manner. For all other 230 V sources and consumers without their own P-BUS interface, the AC-Interface CAV is installed and set to the respective device.

The philippi CAV records the current and voltage of the connected 230 V AC devices and provides the P-BUS with the on-board network voltage, the on-board network current, and the kilowatt-hours consumed since the last reset. The electrical connection is made via screw terminals, and the connection to the P-BUS is made via an M12 T-cable included in the scope of delivery.

Compatible with all P-BUS systems based on philippi system monitors PSM3 or PSL. For currents over 16 A, the external transducer WAC is additionally used.

Original equipment quality

  • Individually tested: every unit is connected and tested in a test environment in Remseck.
  • Brand-name components, as in series production for boatyards.
  • Repairable for decades: spare parts up to 30 years back, own repair centre.
How we manufacture

Technical data

Parameter Value
Measured Phase 230 V / 50 Hz, 1-phase
Current Measurement Range 16 A (internal shunt), up to 100 A with external transducer WAC
AC Connection Screw terminals
P-BUS Connection M12 T-cable (included)
Dimensions L 76 x W 53 x H 46 mm
Item No. 0 7100 0230

Manufacturer and product safety

philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Germany
info@philippi-online.de

Safety information: see the operating manual and data sheet.

Frequently asked questions. Answered briefly.

For which on-board network voltage is the AC-Interface CAV suitable?

For an AC phase with 230 V / 50 Hz.

Do I need the CAV if I already own ACE series chargers or an LAU shore power transfer unit?

No, these devices already provide their AC data directly in a P-BUS-compatible manner. The CAV is installed for power sources and consumers that do not have their own P-BUS connection option, such as Studer X-Tender or Mastervolt devices via an additional interface.

How can I measure currents over 16 A?

The measurement range of the CAV can be extended to up to 100 A via the external transducer WAC.

Goes well with it. Accessories and add-ons.

philippi P-BUS system monitor PSL, main screen 5-inch touchscreen
philippi

P-BUS System Monitor PSL

479,00 €
philippi P-BUS system monitor PSM3, front view
philippi

P-BUS System Monitor PSM3

369,00 €
philippi temperature sensor Temp-HT
philippi

Temperature sensor Temp-HT

20,90 €
philippi panel with rocker switch TAN 101
philippi

Panel with Rocker Switch TAN 101

23,00 €