In detail. VHR 200 isolation relay.

  • Protects the starter battery from unintentional discharge by automatically separating the house battery and the starter battery
  • Time-delayed switching logic (30s on / 10s off) prevents unnecessary fluttering in case of short voltage fluctuations
  • Emergency start function via control button allows jump-starting even with a discharged starter battery
  • Versatile: also usable as an active load relay for enabling consumers during charging operation

In the electrical systems of yachts, boats, expedition and commercial vehicles, the VHR 200 isolation relay ensures that the starter battery and the house battery(s) are connected precisely when the alternator is actually charging. As soon as one of the two batteries is above the switch-on voltage for 30 seconds, the relay connects both circuits; if the voltage drops below the switch-off threshold for 10 seconds, it disconnects them again. This preserves sufficient starting capacity while reliably charging the house battery during driving or engine operation.

Designed for battery banks over 200 Ah, the VHR 200 isolation relay automatically detects whether it is installed in a 12V or 24V electrical system. In addition to its classic use as an isolation relay, it can also be used as an active load relay to specifically enable consumers during charging operation.

Original equipment quality

  • Individually tested: every unit is connected and tested in a test environment in Remseck.
  • Brand-name components, as in series production for boatyards.
  • Repairable for decades: spare parts up to 30 years back, own repair centre.
How we manufacture

Technical data

Feature Value
Nominal voltage 12 + 24 V
Nominal switching current 190 A
Overload / Peak current 400 A / 1500 A
Switch-on voltage 30 s (120 s) 13.8 V (13.4 V) / 27.6 V (26.8 V)
Switch-off voltage 10 s (30 s) 12.5 V (13.0 V) / 25.0 V (26.0 V)
Overvoltage shutdown 16 V / 32 V
Current consumption 1 mA
Connection terminal M8
Dimensions L 124 x W 95 x H 50 mm
Suitable for battery banks over 200 Ah

Manufacturer and product safety

philippi elektrische systeme GmbH
Neckaraue 19
71686 Remseck am Neckar
Germany
info@philippi-online.de

Safety information: see the operating manual and data sheet.

Frequently asked questions. Answered briefly.

For which battery sizes is the VHR 200 designed?

For battery banks over 200 Ah.

Does the VHR 200 work with 12V and 24V electrical systems?

Yes, it is designed for nominal voltages of 12V and 24V and switches automatically in a voltage-dependent and time-delayed manner.

Can I also use the VHR 200 as a load relay?

Yes, it can also be used as an active load relay to enable consumers during charging operation.

What is the emergency start function for?

Both battery circuits can be manually connected via a control button to enable a jump start in case of a discharged starter battery.

Goes well with it. Accessories and add-ons.

philippi battery balancer BLA
philippi

Battery balancer BLA for lead batteries in series

109,00 €
Fischer Panda Panda 8000i PMS
Fischer Panda

Fischer Panda 8000i PMS diesel generator

18.080,00 €
philippi high-power battery charger ACE 12/90
philippi

High-Power Battery Charger ACE 12/90

1.599,00 €
philippi remote control FB-AJ
philippi

Remote control FB-AJ for AJ sine wave inverters

48,00 €
philippi battery monitor BLS, remote display panel for ACE chargers
philippi

Battery Monitor 2.4" BLS

179,00 €

Prefer a quick chat?

Tell us what you are planning. We will tell you honestly what you need and what you don’t.