Manual LAE 233: Installing the Shore Power Unit with Three Circuits.
The LAE 233 shore power unit protects the on-board AC 230 V/50 Hz system: three double-pole thermal circuit breakers (10 A) protect and switch up to three load circuits. The connection is made via 6.3 mm flat-pin connectors on the rear of the panel. The LAE 233 may only be installed with an upstream RCBo (RCD/MCB) residual-current circuit breaker of no more than 25 A. This page summarises the information in the manual.
Intended use
The LAE 233 shore power unit is used to protect the on-board AC 230 V/50 Hz system. The 3 double-pole thermal circuit breakers (10 A) protect and switch up to 3 load circuits. The electrical connection is made via 6.3 mm flat-pin connectors on the rear of the panel.
The LAE 233 may only be installed in conjunction with an upstream RCBo (RCD/MCB) residual-current circuit breaker of no more than 25 A.
Connection
The manual contains no wiring diagram. It states the following: the load circuits are connected via 6.3 mm flat-pin connectors on the rear of the panel; the RCBo (RCD/MCB) of no more than 25 A is located at the input of the LAE 233, upstream of the panel.
Installation notes
- Work on low-voltage AC 230 V/50 Hz system components may only be carried out by qualified electricians.
- Installation must ensure that the rear is protected against accidental contact. To do this, a non-combustible cover must be fitted, or access must only be possible with a tool.
- Make sure there is sufficient clearance to the rear panel or cover because of possible fire risk.
- The installation location must be dry and protected.
- The European standard DIN EN ISO 13297 must be observed during installation.
- The installation instructions are part of the component delivery. They must be kept in a safe place for later maintenance work and passed on to any subsequent owners.
Technical data
| Operating voltage | AC 230 volts / 50 Hz |
| Outputs | Overcurrent circuit breaker 10 A (3 × double-pole) |
| Connection | 6.3 mm flat-pin connectors on the rear |
| Upstream protection | RCBo (RCD/MCB), max. 25 A, at the input |
| Dimensions | W 105 × H 105 × D 70 mm |
CE conformity
According to the manual, the product meets the requirements of EU Directives 2004/108/EC (electromagnetic compatibility; immunity EN 61000-6-1, emissions EN 61000-6-3) and 2006/95/EC (electrical equipment for use within certain voltage limits). Conformity is confirmed by the CE marking.
Disposal
Observe the applicable local regulations for disposal and use the collection points for waste electrical and electronic equipment.
More on the topic: Shore power on board · For questions about installation: Contact · Warranty and repair · All manuals
Manual didn't help? We are happy to help.
Contact