Blue Sea Systems ATD time- and voltage-controlled isolation relay
Blue Sea Systems · Charging current distribution
Blue Sea ATD Time- and Voltage-Controlled Relay
The ATD (Automatic Timer Disconnect) from Blue Sea Systems is a versatile disconnect relay that can protect connected loads in four different ways: by timer, by undervoltage detection, as an automatic charging relay (ACR), or as a simple solenoid switch. This allows the ATD to be adapted to a wide range of requirements in the on-board electrical system.
- Compact dimensions
In detail. Blue Sea ATD Time- and Voltage-Controlled Relay.
Advantages
- Timer: disconnects loads after an adjustable time of 15 minutes to 4 hours, as soon as the control signal drops out
- Undervoltage protection: automatically disconnects loads at adjustable undervoltage (11.0 V / 11.5 V / 12.0 V), even before the timer expires
- ACR operation: automatically combines two battery banks for shared charging via a single charging source and separates them during discharge
- Solenoid operation: connects or disconnects the circuit immediately via a 12V control signal, without time delay
- Test mode disconnects loads after 5 seconds for quick functional check of relay and timer
- Optional charge detection can replace the 12V control signal and saves wiring
Technical data
| Feature | Value |
|---|---|
| Rated voltage | 12 V DC |
| Input voltage range | 9.5–16 V |
| Continuous current | 120 A |
| Intermittent current (5 minutes) | 210 A |
| Cable cross-section | 1 AWG (50 mm²), max. 1/0 AWG |
| Connection studs | 3/8"-16 (10 mm hole) |
| Timer function time range | 15 minutes to 4 hours |
| Protection class | IP67 |
| Ignition protection | ISO 8846 and SAE J1171 |
Manufacturer and product safety
Navico Group Americas LLC (brand Blue Sea Systems)
N85 W12545 Westbrook Crossing
Menomonee Falls, WI 53051
USA
www.bluesea.com/contact
Safety information: see the operating manual and data sheet.
Frequently asked questions. Answered briefly.
When is a time and voltage-controlled disconnect relay like the ATD useful?
Always when loads need to be automatically protected from deep discharge – for example, after switching off the engine, during longer downtimes, or when there is an additional need for charge current distribution between two battery banks. Due to the four selectable operating modes, the ATD covers applications for which otherwise several separate components would be necessary.