The undervoltage protection m-LVD continuously monitors the battery voltage and disconnects less important consumers in case of undervoltage to ensure the starting capability of the engine.
Features
- Fast automatic shutdown in case of undervoltage
- Connection for remote switch to delay shutdown by 10 minutes and mute the alarm
- Integrated LED status indicator, connection for external LED and alarm device
- Suitable for surface mounting as well as partial or full flush mounting
Technical data
- System voltage: 12 V DC
- Max. load capacity (<5 min.): 115 A
- Max. continuous current: 65 A
- Power consumption: 95 mA, disconnected 4 mA
- Load connections: bolts Ø 6 mm
- Protection class: IP67, splash-proof
- Dimensions: 72 x 72 x 65 mm
⚠️Safety data sheet can be found under Downloads!
Downloads
Deutsche Downloads
FAQ
Yes, this is possible. For this, the required fuse size per circuit must be specified when ordering the switch panel.
Yes, before each switchboard, a main fuse must be integrated into the supply line to the switchboard near the battery.
Yes, all common sensors used in the marine and automotive sectors can be connected.