The LIN-Bus Battery Management Shunt SHE 348 from philippi is installed in the negative line of the consumer battery and provides the basic current measurement for philippi battery monitors. It detects charging and discharging currents from 10 mA with ±0.5% accuracy at a continuous current of up to 300 A — suitable for battery capacities up to 50,000 Ah.
- Provides the basic current measurement for philippi monitors BTM2, BLS, and BLM2 — no battery monitoring without SHE 348
- Detects quiescent currents from 10 mA, making creeping consumers visible
- ±0.5% accuracy across the entire measuring range, not just at high currents
- Measure starter battery voltage directly, without a second shunt
- Detect battery temperature directly at the shunt via the TEMP-BT temperature sensor
Resolution and Accuracy: why both matter
The philippi SHE 348 measures from 10 mA — and it is precisely in this range that currents lie that can silently drain a battery bank. A device with a quiescent current of 30 mA draws approximately 0.7 ampere-hours from the battery per day and five per week. A shunt that only measures from around one ampere upwards will not detect this — the bank will still be empty, and the cause will remain undiscoverable.
The second half is the accuracy of ±0.5% across the entire measuring range. The state of charge is not a momentary measurement, but a continuous ampere-hour balance: every single measured value contributes to an ongoing calculation, and measurement errors accumulate over days. Only consistent accuracy across the entire range ensures that the display still matches reality after two weeks.
Starter Battery and Temperature — without a second shunt
The starter battery voltage can be measured directly at the SHE 348 — a second shunt is not necessary for this. This covers the most practically important case: early detection that the starter battery has not been recharged for weeks, for example, because isolation relays or charge converters are no longer working. A second shunt is only needed if a complete current balance with state of charge is also desired for the second bank.
Similarly, the battery temperature is measured directly at the shunt: the TEMP-BT temperature sensor is connected to the SHE 348, and the temperature appears on the monitor in addition to current, voltage, and capacity. A separate temperature interface is not required for this. This is more than just a display: the usable capacity depends on the temperature, and for LiFePO4, charging below freezing is the point at which damage occurs.
Easy Connection
Power is supplied via the voltage measurement line of the consumer battery, and connection is made via M8 bolts. Developed and manufactured in Germany.
Technical Data
| Feature | Value |
|---|---|
| Article number | 070030348 |
| Current carrying capacity | Continuous current 300 A (600 A for 1 min, 1500 A for 0.5 s) |
| Measuring range | 10 mA – 300 A |
| Accuracy | ±0.5% across the entire measuring range |
| Current consumption | 10 mA at 12 V, 5 mA at 24 V |
| Operating voltage | DC 8–40 V |
| Connection | Bolt M8 |
| Temperature measurement | directly at the shunt via TEMP-BT temperature sensor |
| Battery capacity | up to 50,000 Ah |
| Dimensions | L 118 × W 40 × H 65 mm |
Compatibility
The SHE 348 is the basic current measurement for philippi battery monitors BTM2, BLS and BLM2, as well as for the Series 200 switch panels with integrated BTM2 (STV 232, STV 234-2p, STV 236, STV 238, STV 244) and for STV 314 (BLS-Set). The SHE 348 is already included in the BLS-Set and BLM2-Set; it is available separately for retrofitting. For temperature measurement, the TEMP-BT sensor is connected directly to the shunt. If an additional energy source, such as a solar system, is also to be monitored, the SHP 348 energy shunt is used in addition.
Frequently Asked Questions
How accurately does the SHE 348 measure?
With ±0.5% over the entire measuring range, starting from 10 mA, with a continuous charging or discharging current of up to 300 A.
Why is measurement from 10 mA important?
Because quiescent currents are in this order of magnitude. A device with 30 mA draws about 0.7 ampere-hours from the bank per day — invisible to low-resolution devices, noticeable after a week.
Do I need a second shunt for the starter battery?
No. The voltage of the starter battery can be measured directly at the SHE 348. A second shunt is only necessary if a complete current balance with state of charge is also desired for the second bank.
Can I also record the battery temperature?
Yes, via the TEMP-BT temperature sensor, which is connected directly to the SHE 348. A separate temperature interface is not required for this.
Which monitors does the SHE 348 work with?
With the philippi battery monitors BTM2, BLS, and BLM2, as well as the Series 200 switch panels with integrated BTM2. It is already included in the BLS-Set and BLM2-Set.
For which battery capacities is the SHE 348 suitable?
For battery capacities up to 50,000 Ah.
How is the shunt connected?
Via an M8 connection bolt in the negative line of the consumer battery; power is supplied via the voltage measurement line.
Unsure which shunt suits your system? Our team will advise you personally.
⚠️Safety data sheet can be found under Downloads!