The shore power unit LAE 113 from Philippi is a 230 V shore power unit for on-board power supply of yachts with an integrated Schuko socket, which secures and monitors the AC 230 V / 50 Hz mains power takeover. It is suitable for boats where sockets, boilers, and battery chargers are to be supplied via the shore connection.
- Separate protection for sockets, boilers, and battery chargers via 3 individual circuit breakers
- At a glance, you can see if the shore power connection is working correctly – thanks to mains indicator lights
- Schuko socket directly integrated – no additional wiring required for the 230 V on-board socket
- Ready for installation in a closed housing made of self-extinguishing plastic
The LAE 113 takes over shore power at AC 230 V / 50 Hz and directly provides a 230 V on-board power supply via the integrated Schuko socket. 3 two-pole circuit breakers (10 A) protect sockets, boilers, and battery chargers separately. Connection is made at the rear via feed-through terminals for easy and safe installation. Like all units in the LAE 100 series, the Philippi LAE 113 is manufactured in accordance with EN ISO 13297 and contains VDE-tested and approved components.
The completely encapsulated housing of the LAE 113 offers touch and fire protection and allows installation without additional cover – ideal for compact shore power installation on board.
| Feature | Value |
|---|---|
| Rated voltage | AC 230 V / 50 Hz |
| Version | with Schuko socket |
| RCD/MCB circuit breaker | RCBO 16 A / 0.03 A, 2-pole |
| Additional circuit breakers | 3 x two-pole, 10 A (sockets, boiler, battery charger) |
| Monitoring | Mains indicator lights |
| Connection | Rear via feed-through terminals |
| Dimensions | W 260 x H 185 x D 100 mm |
| Cut-out size | W 235 x H 160 mm |
| Standard | EN ISO 13297 |
| SKU | 010001130 |
If the cable length from the shore inlet to the LAE 113 is more than 3 m, a 2-pole circuit breaker such as the Philippi LAE 205 is also required near the inlet, according to EN ISO 13297.
Frequently Asked Questions
For which consumers are the LAE 113 circuit breakers intended?
The 3 two-pole circuit breakers (10 A) of the LAE 113 protect sockets, boilers, and battery chargers separately.
How is the LAE 113 connected?
Connection is made at the rear via feed-through terminals.
How do I know if the shore power connection is working correctly?
The mains indicator lights show the correct mains connection.
Do I need an additional circuit breaker?
Yes, if the supply cable from the inlet to the LAE 113 is longer than 3 m – then an additional circuit breaker such as the Philippi LAE 205 must be provided.
We will be happy to advise you on questions regarding compatibility with your on-board electrical system installation.
⚠️Safety data sheet can be found under Downloads!
Downloads