Automatic voltage-dependent and time-delayed isolating relay for connecting the two attached batteries. The batteries are connected as soon as one of the two batteries is above the cut-in voltage of 13.8 V for 30 seconds. The batteries are disconnected again as soon as the cut-off threshold of 12.5 V is undershot for 10 seconds.
For battery banks > 200 Ah, emergency start function via control button. Can also be used as an active load relay for disconnecting consumers during charging operation.
- Automatic detection of the nominal battery voltage and setting to 12 V or 24 V operating mode.
Dimensions: L 124 x W 95 x H 50 mm
⚠️Safety data sheet can be found under Downloads!
Downloads
Deutsche Downloads
FAQ
Ja dies ist möglich. Dafür muss bei der Bestellung der Schalttafel die benötigte Sicherungsgröße pro Stromkreis angegeben werden.
Ja vor jede Schalttafel muss eine Hauptsicherung in die Zuleitung zur Schalttafel nahe der Batterie integriert werden.
Ja, es können alle im Marine und Fahrzeugbereich üblichen Geber angeschlossen werden.