The Philippi LAU 340 F changeover unit is an automatic changeover device for 3 AC inputs with an integrated RCBO circuit breaker, which safely switches between shore power, inverter and generator in the onboard electrical system of yachts and is designed for higher generator outputs up to 9 kW. The integrated RCBO circuit breaker (40 A / 30 mA) makes separate protection of the outputs unnecessary.
- Integrated RCBO (RCD/MCB) circuit breaker with 40 A / 30 mA saves separate protection of the outputs
- Automatic, delayed switching between up to 3 AC sources prevents short circuits due to phase shift
- Housing also offers space for installing an ACW current transformer for later expansion
- Prepared for connection to the Philippi P-BUS (ACE-T cable required), display of active source and AC voltage on the PSM2/PSL system monitor
The Philippi LAU 340 F changeover unit is the version of the LAU series with a factory-integrated RCBO circuit breaker and is particularly suitable for new installations where the changeover unit is also intended to provide the required residual current and line protection functions. Like the LAU 340, it measures the mains input voltage of each connected source and only switches on generators once they have started up correctly and reached their nominal voltage. An additional output circuit protects the batteries from unwanted discharge by the charger or boiler when operating via the inverter.
Via the Philippi P-BUS and the PSM2 or PSL system monitors, the changeover delay time and voltage thresholds can be individually set, and the active source and AC voltage are displayed on the screen. Since the housing of the LAU 340 F already provides space for an ACW current transformer, the system can be expanded with detailed power consumption logging if required.
| Feature | Value |
|---|---|
| Nominal voltage | 230 V / 50 Hz |
| AC input 1 / 2 | 16 A each |
| AC input 3 (generator) | 40 A (9 kW) |
| RCBO (RCD/MCB) circuit breaker | 40 A / 30 mA, integrated |
| AC output 1 | 40 A |
| AC output 2 | 16 A |
| Protection class | IP X4 |
| Dimensions (W x H x D) | 335 x 270 x 145 mm |
| Expandable | Space for ACW current transformer |
| P-BUS interface | Yes, ACE-T cable required (Art. No. 5 0411 1161) |
| Order No. / SKU | 0 1100 3401 / 011003401 |
The LAU 340 F can be integrated into the Philippi P-BUS system, just like the LAU 340. If you keep the circuit breaker separately or already have a protected system, you can alternatively opt for the simpler LAU 340.
What distinguishes the LAU 340 F from the LAU 340?
The LAU 340 F additionally has an integrated RCBO circuit breaker (40 A / 30 mA) and offers space for installing an ACW current transformer.
What is the current carrying capacity at the generator input?
A maximum of 40 A is possible at the generator input, corresponding to 9 kW.
Can I retrofit a current transformer?
Yes, the housing of the LAU 340 F already provides designated space for this.
Philippi will be happy to advise you on questions regarding compatibility with your onboard electrical system. Order now.
⚠️Safety data sheet can be found under Downloads!