The Philippi Shore Power Unit LAE 232 is a shore power unit for AC 230 V power distribution in the on-board electrical system of boats and vehicles, compatible with the Series 200 circuit distribution panels. It is suitable for yacht owners and campervan builders who require a secure, rear-connectable shore power input with integrated subordinate protection.
- Residual current and personal protection by the RCBO circuit breaker (16 A / 30 mA)
- Two additional two-pole thermal circuit breakers (10 A) for subordinate protection of downstream circuits
- Back-of-hand safe rear-mounted construction protects against electric shock with proper installation
- Compatible with Philippi Series 200 circuit distribution panels, including labeling set
The LAE 232 from Philippi supplies the on-board electrical system with AC 230 V / 50 Hz and protects the power input via an RCBO circuit breaker (16 A / 30 mA) and two two-pole thermal circuit breakers (10 A). A mains indicator shows the mains status, and connection is made via rear terminals. The rear electrical construction is designed to be back-of-hand safe; the panel must be installed so that the rear side is only accessible and covered with tools.
If the supply point is more than 3 m away from the LAE 232, the supply cable must be additionally protected with an MCB circuit breaker (e.g., Philippi LAE 205) near the supply point. The scope of delivery includes an SKZ labeling set for boats and black mounting screws; an SKZ-MOBIL labeling set for vehicles is optionally available.
| Feature | Value |
|---|---|
| Nominal voltage | AC 230 V / 50 Hz |
| RCBO circuit breaker | 16 A / 30 mA |
| Thermal circuit breakers | 2 x 2-pole, 10 A |
| Connection | rear terminals |
| Dimensions | W 105 x H 210 x D 100 mm |
| Mounting cutout | 81 x 186 mm |
| Scope of delivery | SKZ labeling set, mounting screws (optional SKZ-MOBIL) |
| Item No. | 010002320 |
Compatibility: The LAE 232 is designed to match the Philippi Series 200 circuit distribution panels. If the distance to the supply point is more than 3 m, Philippi additionally recommends the MCB circuit breaker LAE 205.
Which circuit distribution panels is the LAE 232 compatible with?
The LAE 232 is designed to be compatible with the Philippi Series 200 circuit distribution panels.
Do I need to consider anything if the distance to the supply point is greater?
Yes, if the distance to the supply point is more than 3 m, the supply cable must be additionally protected near the supply point by an MCB circuit breaker (e.g., LAE 205).
Which circuit breakers are installed in the LAE 232?
An RCBO circuit breaker (16 A / 30 mA) and 2 two-pole thermal circuit breakers (10 A) for AC 230 V / 50 Hz.
Is the LAE 232 also suitable for vehicles?
Yes, an optional SKZ-MOBIL labeling set is available for installation in vehicles.
If you have any questions about compatibility with your circuit distribution panel, the Philippi-online team will be happy to advise you – order now.
⚠️Safety data sheet can be found under Downloads!