The mains control panel LAR indicates the electrically correct connection of the AC on-board network to the AC shore power:
Green light: everything connected correctly; red light: phase (L) and neutral (N) are reversed.
Measuring fault current 1.4 mA, not suitable for AC networks without protective earth, as no fault detection is possible here.
The consumer supply lines are connected via 6.3mm flat spade connectors on the rear.
The panel must be installed in such a way that the rear is only accessible and covered with tools.
The installation cutout can be 12 mm per edge smaller than the panel dimensions (81 x 28.5 mm).
Dimensions: W 105 x H 52.5 x D 50 mm
⚠️Safety data sheet can be found under Downloads!
Downloads
FAQ
Yes, this is possible. For this, the required fuse size per circuit must be specified when ordering the switch panel.
Yes, before each switchboard, a main fuse must be integrated into the supply line to the switchboard near the battery.
Yes, all common sensors used in the marine and automotive sectors can be connected.