The ACR 12/24 isolation relay automatically connects two batteries based on voltage and with a time delay – for shared charging via an alternator, without the batteries being connected when at rest.
Features
- Connection as soon as one battery is above 13.6 V for 30 s
- Disconnection as soon as one battery drops below 12.4 V for 10 s
- Automatic detection of 12 V or 24 V operating mode
- Suitable for battery groups up to 200 Ah
Technical data
- Dimensions: L 99 x W 98 x H 48 mm
⚠️Safety data sheet can be found under Downloads!
Downloads
Deutsche Downloads
FAQ
Yes, this is possible. For this, the required fuse size per circuit must be specified when ordering the switch panel.
Yes, before each switchboard, a main fuse must be integrated into the supply line to the switchboard near the battery.
Yes, all common sensors used in the marine and automotive sectors can be connected.