{"product_id":"dca2","title":"Battery Tank Monitor BTM2","description":"\u003cp\u003ehttps:\/\/youtube.com\/shorts\/bbxmMqXg6Uwhttps:\/\/youtu.be\/MfBSvrmpMEc\u003c\/p\u003e\n\u003ch3\u003eBattery, Tank and Charging Monitor BTM 2.\u003c\/h3\u003e\n\u003cp\u003eIntuitive, 3.5\" color TFT touchscreen graphic display with brightness sensor for automatic adjustment of display brightness. Includes NMEA 2000 interface.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eThe BTM 2 is the further development of the proven battery tank monitor BTM. It\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eincludes an integrated NMEA2000 interface, which provides the battery and\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003etank data to the NMEA2000 network.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eThis allows the battery and tank data to be displayed on compatible plotters.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003ein addition.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eAll components have been improved in terms of standby consumption, so the BTM2 can remain permanently connected to the battery without any problems.\u003c\/p\u003e\n\u003ch4\u003eNMEA 2000\u003c\/h4\u003e\n\u003cp\u003eThe N2K cable is additionally required for connection to the NMEA2000 network. The pluggable cable connects to an NMEA 2000 on-board network via a T-piece (5 0411 1149). If the connection to a Raymarine network is to be made via Seatalk, a Raymarine Seatalk\/NMEA 2000 adapter cable must also be installed (please order from Raymarine - A06045).\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eBattery Monitoring\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003ePrecise battery information on current voltage, charge or\u003c\/p\u003e\n\u003cp\u003edischarge current, remaining time, temperature and state of charge of the consumer battery. Historical values for the number of charging cycles, deep discharges and average discharge depth give you an overview of battery usage. The voltages of up to 2 starter or bow batteries can be monitored.\u003c\/p\u003e\n\u003cp\u003eThe SHE 300 shunt is not included in the scope of delivery of the BTM2 - please order it separately!\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSolar Yield Measurement\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eIf one or more solar panels are to be monitored, you can display the current yield of your solar panels using a power measurement shunt SHP300.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eTank measurement\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eAll known Philippi tank sensors such as TGT\/ TGW, UTV, TDS\/TDN and DFS can be connected, as can existing tank sensors from other manufacturers with 10-180Ω \/ 240-33Ω \/ 0-5 V \/ 0-10 V\/ 4-20 mA signals. Each tank can be individually configured for clear assignment, and adaptation to non-linear tank geometries is also possible. Individual tank alarms can be defined for monitoring.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlarm\/Relay contact\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eAlso new is the potential-free changeover contact with which\u003c\/p\u003e\n\u003cp\u003ein conjunction with a remote-controlled battery\u003c\/p\u003e\n\u003cp\u003emain switch FBR 265 enables voltage- and, importantly, capacity-dependent\u003c\/p\u003e\n\u003cp\u003eenergy management and deep discharge protection.\u003c\/p\u003e\n\u003cp\u003eThis allows consumers to be switched off early before impending\u003c\/p\u003e\n\u003cp\u003edeep discharge and not only when the battery\u003c\/p\u003e\n\u003cp\u003eis deeply discharged. This is particularly important for lithium battery systems,\u003c\/p\u003e\n\u003cp\u003ewhose flat discharge characteristic makes timely voltage shutdown\u003c\/p\u003e\n\u003cp\u003eimpossible.\u003c\/p\u003e\n\u003cp\u003eThe tank sensors, the \"SHE300\" shunt and the NMEA 2000 connection cable \"\u003ca href=\"https:\/\/www.philippi-online.de\/produkt\/n2k-kabel\/\"\u003eN2K cable\u003c\/a\u003e\" or the FBR265 relay must be ordered separately.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperating voltage: \u003c\/b\u003e8-64 V\u003cb\u003e \u003c\/b\u003e\u003cbr\u003e\u003cb\u003eCurrent consumption: \u003c\/b\u003emax. 70 mA @ 12V, Stand-by: 6 mA\u003cb\u003e \u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003eL 105 x W 105 x H 35 mm\u003cbr\u003e\u003cb\u003eInstallation cutout: \u003c\/b\u003e88 x 88 mm\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":53556977795409,"sku":"070004000","price":285.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/070004000_DCA2.png?v=1776430570","url":"https:\/\/www.philippi-online.de\/en\/products\/dca2","provider":"philippi elektrische systeme GmbH","version":"1.0","type":"link"}