{"title":"Tank Gauges \u0026 Tank Monitors","description":"\u003ch2\u003eTank gauges and tank monitors for boats, yachts and motorhomes\u003c\/h2\u003e\n\u003cp\u003eA tank gauge shows the level that the tank sender measures in the tank. Here you will find analogue round gauges for one tank, digital tank monitors for several tanks and batteries, the alarm panel for black water tanks, plus interface and installation accessories. The matching tank senders are listed under \u003ca href=\"\/en\/collections\/tanksensoren-marine\"\u003eTank senders and tank sensors\u003c\/a\u003e; the guide \u003ca href=\"\/en\/pages\/fuellstandsmessung\"\u003eTank monitoring on board\u003c\/a\u003e gives an overview.\u003c\/p\u003e\n\u003ch3\u003eWhich tank gauge for how many tanks?\u003c\/h3\u003e\n\u003cdiv class=\"ak-table\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth scope=\"col\"\u003eDisplay\u003c\/th\u003e\u003cth scope=\"col\"\u003eScope\u003c\/th\u003e\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003eFuel\/Water 52 mm round gauge\u003c\/td\u003e\u003ctd\u003e1 tank\u003c\/td\u003e\u003ctd\u003eAnalogue, for TGT and TGW; on 24 V with the Rturo series resistor\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eWaste UTV round gauge\u003c\/td\u003e\u003ctd\u003e1 tank\u003c\/td\u003e\u003ctd\u003eAnalogue, matches the UTV ultrasonic tank sender, 12 V and 24 V\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eTCS tank monitor\u003c\/td\u003e\u003ctd\u003eup to 3 tanks, 2 battery voltages\u003c\/td\u003e\u003ctd\u003e2.4″ touchscreen, alarm thresholds per tank\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eVTM 2 tank monitor\u003c\/td\u003e\u003ctd\u003eup to 4 tanks, 2 battery banks\u003c\/td\u003e\u003ctd\u003e3.5″ touchscreen, potential-free relay output\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eBTM2 battery and tank monitor\u003c\/td\u003e\u003ctd\u003etank levels plus battery monitor with shunt\u003c\/td\u003e\u003ctd\u003e3.5″ touchscreen, NMEA 2000 to the chartplotter\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eFAF black water tank alarm\u003c\/td\u003e\u003ctd\u003efull alarm for the black water tank\u003c\/td\u003e\u003ctd\u003eVisual and audible alarm, with TRS 130, RSW or DSW\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe philippi tank senders TGW, TGT, TDS\/TDN, TDT and UTV connect directly to the TCS, VTM 2 and BTM2 digital monitors, as do third-party senders with 10–180 Ω, 240–33 Ω, voltage or 4–20 mA signals. You set volume and tank shape for each tank, so the reading is right even for wedge-shaped and moulded tanks. Round gauges fit neatly into the TAN 101 panel with rocker switch. The UTI universal tank interface connects pressure probes to existing analogue gauges.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions about tank gauges\u003c\/h3\u003e\n\u003ch4\u003eWhich tank gauge suits my tank sender?\u003c\/h4\u003e\n\u003cp\u003eThe Fuel\/Water 52 mm round gauge suits the TGT and TGW tank senders, the Waste gauge the UTV ultrasonic tank sender. The TCS, VTM 2 and BTM2 tank monitors work with all philippi tank senders and common third-party senders with resistance, voltage or current signals. For pressure probes on an analogue gauge you need the UTI interface.\u003c\/p\u003e\n\u003ch4\u003eCan I see several tanks on one display?\u003c\/h4\u003e\n\u003cp\u003eYes. The TCS tank monitor shows up to three tanks, the VTM 2 up to four, both with two battery voltages as well. The BTM2 battery and tank monitor shows tank levels together with the state of charge and current of the house battery. A round gauge, by contrast, always shows exactly one tank. For a single water or diesel tank, a round gauge in the TAN 101 panel is often enough.\u003c\/p\u003e\n\u003ch4\u003eCan I run the tank gauge on 24 V?\u003c\/h4\u003e\n\u003cp\u003eThe TCS and VTM 2 tank monitors work on 12 V and 24 V, the BTM2 on 8 to 64 V. The Fuel\/Water 52 mm round gauge is designed for 12 V; on 24 V you run it with the Rturo series resistor. The FAF black water tank alarm is available in a 12 V and a 24 V version.\u003c\/p\u003e\n\u003ch4\u003eCan the tank levels be shown on the chartplotter?\u003c\/h4\u003e\n\u003cp\u003eYes, via NMEA 2000. The BTM2 battery and tank monitor has a built-in NMEA 2000 interface and passes battery and tank data to compatible chartplotters; you also need the N2K cable for this. The TCS and VTM 2 tank monitors have no NMEA 2000 interface. Alternatively, the Gobius C tank sensor in its NMEA 2000 version sends its level directly into the network.\u003c\/p\u003e\n","products":[{"product_id":"waste-utv","title":"Round Measuring Instrument for UTV Waste UTV","description":"\u003cp\u003eThe round measuring instrument for UTV Waste from Turotest displays the fill level analogously, matching the UTV ultrasonic sensor, and is suitable for 12V and 24V vehicle electrical systems.\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eDirectly compatible with the UTV ultrasonic tank sensor – no additional signal converter required\u003c\/li\u003e\n\n\u003cli\u003eCan be used for both common on-board network voltages (12 V and 24 V)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eUTV ultrasonic sensor\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e12 V and 24 V DC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Turotest","offers":[{"title":"Default Title","offer_id":52832130367825,"sku":"207782041","price":56.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/207782041_WasteWaterUTV.png?v=1792761239"},{"product_id":"faf","title":"Wastewater tank monitoring FAF","description":"\u003cp\u003eThe philippi FAF holding tank monitor is an alarm panel for boats and RVs that monitors the fill level of the holding tank with visual and audible alarms. It is available for 12V and 24V electrical systems and compatible with TRS 130, RSW, or DSW tank sensors.\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eTimely warning of a full holding tank before overflow occurs\u003c\/li\u003e\n\n\u003cli\u003eAudible alarm can be acknowledged by pressing a button without deactivating the display\u003c\/li\u003e\n\n\u003cli\u003eCompact panel for easy integration into existing switch panels\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003eThe FAF signals a full holding tank both visually and audibly, making operation safer without manual tank level checks. In combination with the TRS 130 tank sensor, the notification is made in accordance with standards at 3\/4 fill level as per the holding tank regulation; alternatively, the FAF can also be combined with the RSW or DSW float switches. The tank sensor is not included in the scope of delivery and must be ordered separately to match the installation situation.\u003c\/p\u003e\n\u003ctable\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eFeature\u003c\/th\u003e\n\n\u003cth\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eVersions\u003c\/td\u003e\n\n\u003ctd\u003eFAF -12 V \/ FAF -24 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAlarm\u003c\/td\u003e\n\n\u003ctd\u003evisual and audible, can be acknowledged by button\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCompatible tank sensors\u003c\/td\u003e\n\n\u003ctd\u003eTRS 130 (3\/4 full notification according to holding tank regulation), RSW, DSW\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\n\u003ctd\u003e105 x 52.5 x 50 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSKU\u003c\/td\u003e\n\n\u003ctd\u003e028011020 (12 V) \/ 028021020 (24 V)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhich tank sensors are compatible with the FAF holding tank monitor?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe FAF is compatible with TRS 130 tank sensors (3\/4 full notification according to holding tank regulation) or RSW\/DSW.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes a tank sensor need to be ordered additionally?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eYes, the FAF is an alarm panel and requires a suitable tank sensor (TRS 130 or RSW\/DSW) to be installed separately in the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the audible alarm of the FAF turned off?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe audible alarm can be acknowledged via a button on the panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor which electrical system voltage is the FAF available?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe FAF is available for 12V and 24V electrical systems.\u003c\/p\u003e\n\u003cp\u003eFor questions about the suitable tank sensor combination, the philippi team will be happy to advise you. Order now.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"DC12V","offer_id":52832133120337,"sku":"028011020","price":49.0,"currency_code":"EUR","in_stock":true},{"title":"DC24V","offer_id":53258894541137,"sku":"028021020","price":49.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/028011020_FAF.png?v=1776159934"},{"product_id":"fuel-water-52","title":"Round Measuring Instrument Fuel \/ Water 52mm","description":"\u003cp\u003eThe Fuel\/Water 52 mm round instrument is an analog tank gauge that displays the fill level compatible with the TGT (Fuel) and TGW (Water) series tank sensors.\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eCompatible with TGT (Fuel) or TGW (Water) series tank sensors\u003c\/li\u003e\n\n\u003cli\u003eCompact 52 mm round format\u003c\/li\u003e\n\n\u003cli\u003eOperates on 12 V DC; for 24 V DC, the Rturo series additional resistor is required\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCan I operate the instrument on 24 V?\u003c\/strong\u003e Yes, with the additional Rturo series resistor.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich tank sensors is the instrument compatible with?\u003c\/strong\u003e The TGT (Fuel) and TGW (Water) series.\u003c\/p\u003e","brand":"Turotest","offers":[{"title":"Fuel","offer_id":52832150258001,"sku":"207780541","price":56.0,"currency_code":"EUR","in_stock":true},{"title":"Wasser","offer_id":53258896769361,"sku":"207780601","price":56.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/207780541_Fuel-Water.png?v=1792761142"},{"product_id":"tan-101","title":"Panel with Rocker Switch TAN 101","description":"\u003cp\u003eThe philippi Panel with Rocker Switch TAN 101 is a flush-mount holder for 52 mm diameter round instruments that can be switched on and off directly on the panel via an integrated rocker switch – ideal for clean instrument installation on yachts, campers, or vehicles.\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eClean installation of round instruments (e.g., fuel gauges) without a separate switch in the onboard electrical system\u003c\/li\u003e\n\n\u003cli\u003eIntegrated rocker switch (0-1) for direct on\/off switching of the instrument\u003c\/li\u003e\n\n\u003cli\u003eCompact design, suitable for common 52 mm round instruments\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ctable\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eFeature\u003c\/th\u003e\n\n\u003cth\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eItem No.\u003c\/td\u003e\n\n\u003ctd\u003e0 2800 0510 (SKU 028000510)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSuitable for\u003c\/td\u003e\n\n\u003ctd\u003eRound instruments Ø 52 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSwitch\u003c\/td\u003e\n\n\u003ctd\u003eIntegrated rocker switch (0-1)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\n\u003ctd\u003e110 x 72.5 x 40 mm (90 mm with instrument)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/table\u003e\n\u003ch3\u003eIs the instrument included?\u003c\/h3\u003e\n\u003cp\u003eNo, the TAN 101 panel is the flush-mount holder with a rocker switch; the round instrument (e.g., a fuel tank level indicator) is ordered separately.\u003c\/p\u003e\n\u003cp\u003eOrder now and integrate instruments cleanly into your onboard electrical system.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832152617297,"sku":"028000510","price":23.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/028000510_TAN101.png?v=1776670196"},{"product_id":"vorwiderstand-rturo","title":"Series resistor for round measuring instrument Rturo","description":"\u003cp\u003eThe Turotest series resistor Rturo from Turotest allows the operation of Turotest round instruments such as Fuel\/Water 52 or the Temperature Round Gauge on 24V vehicle electrical systems, although these are originally designed for 12V.\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eEncapsulated, robust design for permanent installation in the vehicle electrical system\u003c\/li\u003e\n\n\u003cli\u003eMakes 12V round instruments 24V capable without modification to the instrument itself\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOrder No.\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 0800 2000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCompatible with\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eTurotest Fuel\/Water 52, Temperature Round Gauge 120°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Turotest","offers":[{"title":"Default Title","offer_id":52832162775377,"sku":"208002000","price":9.9,"currency_code":"EUR","in_stock":true}]},{"product_id":"tcs","title":"Tank Monitor 2.4\" TCS","description":"\u003cp\u003eThe philippi Tank Monitor TCS is a digital tank and battery monitor that displays up to 3 tanks and 2 battery voltages for yachts, campers, and off-road vehicles on a 2.4\" TFT touchscreen. It operates with 12\/24 V, is compatible with all common tank sensors, and requires no configuration software.\u003c\/p\u003e\n\u003ch3\u003eYour Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eUp to 3 tanks and 2 battery voltages at a glance, without pressing a button\u003c\/li\u003e\n\n\u003cli\u003eCompatible with all philippi tank sensors (TGT\/TGW, UTV, TDS\/TDN\/TDT) as well as third-party manufacturers (10-180\/240-33 Ohm, 0-3 V, 4-20 mA)\u003c\/li\u003e\n\n\u003cli\u003eIndividual configuration per tank, also for non-linear tank geometries\u003c\/li\u003e\n\n\u003cli\u003eFreely definable minimum\/maximum alarm thresholds per tank and battery with acoustic signal\u003c\/li\u003e\n\n\u003cli\u003eIntegrated brightness sensor automatically dims in the dark and saves energy\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003eThe philippi Tank Monitor TCS monitors fill levels and battery voltages of a complete onboard system on a compact display. For each connected tank sensor, volume, tank type, and sensor type can be stored in the setup, so that fill levels can be displayed optionally in liters, percent, or as a pure bar. For non-rectangular tanks, the display can be adapted to the actual tank geometry using five freely definable fill level values (0, 25, 50, 75, 100%).\u003c\/p\u003e\n\u003cp\u003eAll settings are made conveniently via the touchscreen; no additional programming tools are necessary. The configuration remains saved even if the power supply fails and is immediately available again after switching back on.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003ctable\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDisplay\u003c\/th\u003e\n\n\u003ctd\u003e2.4\" TFT color touchscreen with brightness sensor\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDisplay\u003c\/th\u003e\n\n\u003ctd\u003eTanks 1–3, adjustable \/ 2 battery voltages\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSuitable for Tank Sensors\u003c\/th\u003e\n\n\u003ctd\u003ePressure probe, float sensor, ultrasonic\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRelay Output\u003c\/th\u003e\n\n\u003ctd\u003eno\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNominal Voltage\u003c\/th\u003e\n\n\u003ctd\u003e12 \/ 24 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eCurrent Consumption\u003c\/th\u003e\n\n\u003ctd\u003emax. 50 mA @ 12 V, stand-by 6 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions\u003c\/th\u003e\n\n\u003ctd\u003eW 105 x H 75 x D 28 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eMounting Cutout\u003c\/th\u003e\n\n\u003ctd\u003eW 87 x H 65 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNMEA 2000\u003c\/th\u003e\n\n\u003ctd\u003eno\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFor larger systems with up to 4 tanks, relay output, or NMEA-2000 connection, philippi offers suitable alternatives in the same modular system with the Tank Monitor VTM 2 or BTS-T.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many tanks can the TCS monitor?\u003c\/strong\u003e\u003cbr\u003eUp to 3 tanks, in parallel 2 battery groups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich tank sensors can I connect?\u003c\/strong\u003e\u003cbr\u003eAll known philippi tank sensors as well as third-party sensors with 10-180\/240-33 Ohm, 0-3 V, or 4-20 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I set alarms for individual tanks?\u003c\/strong\u003e\u003cbr\u003eYes, individual minimum and maximum alarm thresholds per tank are freely definable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the TCS have an NMEA-2000 connection?\u003c\/strong\u003e\u003cbr\u003eNo, for this, philippi offers the identical Tank Monitor BTS-T with an NMEA-2000 interface.\u003c\/p\u003e\n\u003cp\u003eOrder now or get advice on the suitable tank sensor combination.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832168575313,"sku":"071003041","price":179.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071003041_TCS.png?v=1792761038"},{"product_id":"vtm","title":"Tank Monitor 3.5\" VTM 2","description":"\u003cp\u003eThe philippi Tank Monitor 3.5\" VTM 2 is an onboard monitoring device that displays up to 4 tanks and 2 battery banks on a 3.5\" TFT touchscreen, supporting all common tank sensors – for boats, yachts, RVs, and vehicles.\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eMonitor up to 4 tanks and 2 battery voltages simultaneously without pressing a button\u003c\/li\u003e\n\n\u003cli\u003eCompatible with all philippi tank sensors (TGT\/TGW, UTV, TDS\/TDN\/TDT) as well as third-party sensors (10-180 Ω \/ 240-33 Ω \/ 0-3(10) V \/ 4-20 mA)\u003c\/li\u003e\n\n\u003cli\u003eIndividual configuration per tank, even for non-linear tank geometries\u003c\/li\u003e\n\n\u003cli\u003ePotential-free relay output with freely configurable function, e.g., for alarm messages\u003c\/li\u003e\n\n\u003cli\u003eIntegrated brightness sensor automatically dims in the dark and saves energy\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003eThe Tank Monitor VTM 2 is the consistent further development of philippi's digital tank monitors and offers a fourth tank display as well as an additional potential-free relay output compared to the smaller BTS-T model. For each connected tank sender, volume, tank type, and sensor type can be stored in the setup; the level display can be individually adapted to non-rectangular tank geometries. If the set alarm thresholds for tank or battery voltage are undershot or exceeded, the VTM 2 reports this via an audible alarm that can be acknowledged.\u003c\/p\u003e\n\u003cp\u003eThanks to the interval query of the tank senders and the automatic power-save mode below 11.5 V \/ 23 V, the VTM 2's power consumption remains low even in continuous operation.\u003c\/p\u003e\n\u003ctable\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eFeature\u003c\/th\u003e\n\n\u003cth\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\n\u003ctd\u003e3.5\" TFT color touchscreen with brightness sensor\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\n\u003ctd\u003eTanks 1–4, adjustable \/ 2 battery voltages\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSuitable for tank senders\u003c\/td\u003e\n\n\u003ctd\u003ePressure sensor, float sensor, ultrasonic, flow sensor\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eRelay output\u003c\/td\u003e\n\n\u003ctd\u003e1 potential-free contact, function configurable\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\n\u003ctd\u003e12 \/ 24 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\n\u003ctd\u003emax. 80 mA @ 12 V, standby 14 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\n\u003ctd\u003eW 105 x H 105 x D 35 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMounting cutout\u003c\/td\u003e\n\n\u003ctd\u003eW 88 x H 88 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/table\u003e\n\u003cp\u003eThe VTM 2 is compatible with all philippi tank sensors as well as suitable level sensors from other manufacturers. Those who also require an NMEA-2000 connection should opt for the Battery-Tank-Monitor BTM2.\u003c\/p\u003e\n\u003ch3\u003eHow many tanks can the VTM 2 monitor?\u003c\/h3\u003e\n\u003cp\u003eUp to 4 tanks, in parallel, 2 battery banks voltage-monitored.\u003c\/p\u003e\n\u003ch3\u003eWhat can the relay output control?\u003c\/h3\u003e\n\u003cp\u003eThe potential-free contact is freely configurable, for example for alarm messages.\u003c\/p\u003e\n\u003ch3\u003eWhich tank senders can I connect?\u003c\/h3\u003e\n\u003cp\u003eAll known philippi tank sensors such as TGT\/TGW, UTV, and TDS\/TDN\/TDT, as well as third-party sensors with 10-180 Ω, 240-33 Ω, 0-3(10) V, or 4-20 mA.\u003c\/p\u003e\n\u003ch3\u003eDoes the VTM 2 have an NMEA-2000 interface?\u003c\/h3\u003e\n\u003cp\u003eNo, for an NMEA-2000 connection, the Battery-Tank-Monitor BTM2 is the suitable alternative.\u003c\/p\u003e\n\u003cp\u003eFor questions about the appropriate tank sensor combination, the philippi team will be happy to advise you – order now.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832171557201,"sku":"071004012","price":249.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071004012_VTM.png?v=1792761039"},{"product_id":"btm2","title":"Battery Tank Monitor BTM2","description":"\u003cp\u003eThe philippi Battery and Tank Monitor BTM2 is a combined onboard monitoring device that displays battery voltage, state of charge, current, and tank levels on a 3.5\" color touchscreen and can be directly integrated into your onboard network via an integrated NMEA 2000 interface – for boats, yachts, motorhomes, and vehicles.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReplaces multiple individual displays with a central display for battery and tank monitoring\u003c\/li\u003e\n\u003cli\u003eTank sensors are measured directly at the BTM2, with no additional interface\u003c\/li\u003e\n\u003cli\u003eIntegrated NMEA 2000 interface also displays battery and tank data on compatible chart plotters\u003c\/li\u003e\n\u003cli\u003eHistorical values for charge cycles, deep discharges, and average discharge depth provide an overview of battery usage\u003c\/li\u003e\n\u003cli\u003ePotential-free changeover contact enables capacity-dependent deep discharge protection in conjunction with the FHR 265\u003c\/li\u003e\n\u003cli\u003eExpandable with solar yield measurement and connection to an ACE series charger\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BTM2 is the advanced version of the proven BTM battery and tank monitor and precisely measures the current voltage, charging\/discharging current, remaining time, temperature, and state of charge of the consumer battery via the SHE 348 shunt; additionally, the voltages of up to two starter or bow batteries can be monitored. New features compared to the previous model include operation with 12–48 V operating voltage and the standard NMEA 2000 interface, through which all battery and tank data can also be displayed on a compatible plotter.\u003c\/p\u003e\n\u003cp\u003eFor tank monitoring, the philippi BTM2 supports all known tank sensors such as TGT\/TGW, UTV, TDS\/TDN, and DFS, as well as third-party sensors with signals 10-180 Ω, 240-33 Ω, 0-5 V, 0-10 V or 4-20 mA – each tank can be individually configured, even for non-linear tank geometries. The tank sensors are measured directly at the BTM2; no additional interface is needed. Especially with lithium battery systems with their flat discharge curve, the potential-free relay contact in combination with the remote-controlled main switch FHR 265 is valuable, as consumers can be shut off early before a threatening deep discharge. All sensors and devices can be connected at a central point via the Connect HUB and routed to the display with only one cable.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e8–64 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003emax. 70 mA @ 12 V, standby 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eL 105 x W 105 x H 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting cutout\u003c\/td\u003e\n\u003ctd\u003e88 x 88 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNMEA 2000 interface\u003c\/td\u003e\n\u003ctd\u003eYes, N2K cable required as accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTo be ordered separately\u003c\/td\u003e\n\u003ctd\u003eTank sensors, shunt SHE 348, N2K cable, if necessary FHR 265 \/ shunt SHP 348\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe BTM2 is compatible with all philippi tank sensors, the remote-controlled main switch FHR 265, the power measurement shunt SHP 348 for solar monitoring, and ACE series chargers. For connection to a Raymarine network via SeaTalk, an additional Raymarine adapter cable Seatalk\/NMEA 2000 (A06045) is required.\u003c\/p\u003e\n\u003ch3\u003eIs the shunt included?\u003c\/h3\u003e\n\u003cp\u003eNo, the SHE 348 shunt is not included with the BTM2 and must be ordered separately.\u003c\/p\u003e\n\u003ch3\u003eCan I also monitor my solar system?\u003c\/h3\u003e\n\u003cp\u003eYes, with an additional power measurement shunt SHP 348, the BTM2 also displays the current yield of your solar panels.\u003c\/p\u003e\n\u003ch3\u003eWhat is the easiest way to connect sensors and devices?\u003c\/h3\u003e\n\u003cp\u003eVia the Connect HUB – it bundles all connections and routes only a single cable to the display.\u003c\/p\u003e\n\u003ch3\u003eWhat do I need for NMEA 2000 connectivity?\u003c\/h3\u003e\n\u003cp\u003eIn addition to the BTM2, the N2K cable is required, which establishes the connection to your NMEA 2000 onboard network via a T-piece.\u003c\/p\u003e\n\u003cp\u003eIf you have any questions about compatibility with your onboard network, the philippi team will be happy to advise you – order now.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832171884881,"sku":"071004050","price":285.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071004050_BTM2.png?v=1775737175"},{"product_id":"uti","title":"Universal Tank Interface UTI","description":"\u003cp\u003eThe philippi Universal Tank Interface (UTI) is an interface for the onboard power system of boats and vehicles. It connects TDS, TDN, or TDT tank sensors to analog round instruments by converting the tank sensor's 4–20 mA signal into a voltage signal (0.5–2.5 V) or resistance signal (10–180 Ω).\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003eAdapts various tank sensor systems to existing analog measuring instruments without having to replace the display\u003c\/li\u003e\n\n\u003cli\u003eAny combination is possible, e.g., conversion from 10–180 Ω to 240–33 Ω\u003c\/li\u003e\n\n\u003cli\u003eTank height adjustable directly on the interface so that the full signal exactly matches the display\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003eThe philippi UTI is used wherever tank sensors with a current signal (TDS, TDN, TDT tank sensors) meet existing analog round instruments with voltage or resistance input. Instead of replacing the entire display, the UTI converts the signal accordingly and can be precisely calibrated to the respective tank geometry using the adjustable tank height.\u003c\/p\u003e\n\u003ctable\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eProperty\u003c\/th\u003e\n\n\u003cth\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\n\u003ctd\u003e10-30 V DC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eOutput signals\u003c\/td\u003e\n\n\u003ctd\u003e10-180 Ω, 240-33 Ω, 0.5-2.5 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\n\u003ctd\u003eW 130 x H 80 x D 42 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSKU\u003c\/td\u003e\n\n\u003ctd\u003e080001500\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Input side suitable for tank sensors with resistance signal 10-180 Ω or 240-33 Ω, voltage output 0-10 V or current signal 4-20 mA (e.g., philippi TDS, TDN, TDT tank sensors). Output side suitable for instruments with resistance input 10-180 Ω or 240-33 Ω or voltage input.\u003c\/p\u003e\n\u003ch3\u003eWhat is the UTI needed for?\u003c\/h3\u003e\n\u003cp\u003eFor connecting TDS, TDN, or TDT tank sensors to analog round instruments with voltage or resistance input.\u003c\/p\u003e\n\u003ch3\u003eCan I adjust the tank height?\u003c\/h3\u003e\n\u003cp\u003eYes, you can set the tank height directly on the interface so that the full signal of the tank sensor matches the display.\u003c\/p\u003e\n\u003cp\u003eOrder now and easily adapt your tank display to your onboard power system.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832173982033,"sku":"080001500","price":89.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/080001500_UTI.png?v=1792761141"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/collections\/071004012_VTM.png?v=1793341955","url":"https:\/\/www.philippi-online.de\/en\/collections\/tankanzeigen-marine.oembed","provider":"philippi elektrische systeme GmbH","version":"1.0","type":"link"}