{"title":"Onboard monitoring","description":"","products":[{"product_id":"fhc-265","title":"Remote-controlled P-bus circuit breaker FHC 265","description":"\u003cp\u003eRemote-controlled power disconnect switch with adjustable deep discharge protection and overvoltage shutdown with P-Bus interface.\u003c\/p\u003e\n\u003cp\u003eThe FHC 265 remote-controlled main switch is used for convenient switching of the on-board power supply or the power supply of high-current consumers such as winches, anchor winches, inverters (energy management). The adjustable undervoltage and overvoltage protection simultaneously protects the battery from deep discharge.\u003c\/p\u003e\n\u003cp\u003eFor applications with a continuous current load greater than 260 A (e.g. bow thrusters), a solution with a current carrying capacity of up to 500 A can be provided by combining the TSC interface with the FBR 500.\u003c\/p\u003e\n\u003cp\u003eControl via control button or P-BUS. All settings can be adjusted on the PSM\/PSL.\u003c\/p\u003e\n\u003cp\u003eFor independent operation of the main switch from the P-BUS, we recommend installing an external control button.\u003c\/p\u003e\n\u003cp\u003eAt the relay terminals on the front, the relay can be emergency operated via a short control line.\u003c\/p\u003e\n\u003cp\u003eMounted M12-T cable for easy integration into the P-Bus.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRated voltage:\u003c\/b\u003e 12 + 24 V DC\u003cbr\u003e\u003cb\u003emax. continuous current:\u003c\/b\u003e 260 A\u003cbr\u003e\u003cb\u003eSelf power consumption:\u003c\/b\u003e 2 mA\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 124 x W 95 x H 50 mm\u003ca aria-label=\"Weitere Informationen\" href=\"\/wp-content\/uploads\/philippi\/Info\/philippi20DE-PBUS_FERNSTEUERBARE.pdf%20\" tabindex=\"-1\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832126599505,"sku":"083022720","price":229.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/083022770_FHC.png?v=1775827091"},{"product_id":"fhc-265-bipolar","title":"Remote-controlled P-bus circuit breaker FHC 265 Bipolar","description":"\u003cp\u003e2-pole version of the remote-controlled battery disconnect switch FBC. Manual emergency operation directly at the relays is possible.\u003cbr\u003eDelivery includes M12 T-cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRated voltage:\u003c\/b\u003e 12 + 24 V DC\u003cbr\u003e\u003cb\u003eMax. continuous current:\u003c\/b\u003e 2x 260 A\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.philippi-online.de\/wp-content\/uploads\/2024\/03\/TSC_V2E-D.pdf\" rel=\"noopener\" tabindex=\"-1\" target=\"_blank\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832126796113,"sku":"083022755","price":399.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/083022755_FHC-BI.png?v=1775828486"},{"product_id":"xcom-can","title":"P-BUS-Studer Bridge XCOM-CAN","description":"\u003cp\u003eThe Xcom CAN Bridge is required to display data from the Xtender inverter\/chargers and to configure settings from the system monitor. Power is supplied via the Xtender network.\u003cbr\u003eIncludes M12 T-cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 113 x W 76 x H 25 mm\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"studer","offers":[{"title":"Default Title","offer_id":52832127091025,"sku":"700069042","price":379.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/700069042-xcom-can.png?v=1780997889"},{"product_id":"rsw","title":"Float Switch RSW","description":"\u003cp\u003eFloat switch for side mounting in tanks for level detection. Depending on the mounting position, the switch opens or closes when the fluid level rises or falls.\u003cbr\u003eThe housing is made of black polyamide, suitable for oil and petrol.\u003cbr\u003eSwitching current max. 0.5 A.\u003c\/p\u003e\n\u003cp\u003eInstallation from inside to outside.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832127811921,"sku":"089300008","price":20.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/089300008_RSW.png?v=1780992507"},{"product_id":"dsw","title":"Float switch DSW","description":"\u003cp\u003eThe float switch can be mounted on the tank from the outside without having to set a lock nut from the inside. Thanks to a sealing ring that is tightened from the outside, subsequent installation from the outside is very easy.\u003cbr\u003eMounting hole: ø 22 - 24 mm.\u003cbr\u003e12 mm wide seal for wall thicknesses up to max. 5 mm, only suitable for low filling pressure.\u003cbr\u003eSwitching current max. 0.5 A.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832127975761,"sku":"089300019","price":22.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/089300019.png?v=1768491118"},{"product_id":"waste-utv","title":"Round Measuring Instrument for UTV Waste UTV","description":"\u003cp\u003eDisplay instrument suitable for UTV ultrasonic sensor.\u003c\/p\u003e\n\u003cp\u003eSuitable for 12 V and 24 V DC.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"turotest","offers":[{"title":"Default Title","offer_id":52832130367825,"sku":"207782041","price":56.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/207782041_WasteWaterUTV.png?v=1781001086"},{"product_id":"faf","title":"Wastewater tank monitoring FAF","description":"\u003cp\u003eAlarm panel for fecal tank monitoring with visual and acoustic alarm. The acoustic alarm can be acknowledged with a button.\u003c\/p\u003e\n\u003cp\u003eSuitable for TRS 130 or RSW\/DSW sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eW 105 x H 52.5 x D 50 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"DC12V","offer_id":52832133120337,"sku":"028011020","price":49.0,"currency_code":"EUR","in_stock":true},{"title":"DC24V","offer_id":53258894541137,"sku":"028021020","price":49.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/028011020_FAF.png?v=1776159934"},{"product_id":"cmr-232-s","title":"P-Bus Relay Module CMR 232 S","description":"\u003cp\u003e\u003cb\u003eDIGITAL SWITCHING AND CONTROL VIA PSM AND PSL\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe new relay module enables the fused switching of 2-pole systems with 2 consumers, up to a maximum of 30A via the integrated fuse or circuit breaker.\u003cbr\u003eVia the digital switching input on the CMR, the respective channel can also be switched by means of a button.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntegrated emergency operation:\u003c\/b\u003e\u003cbr\u003eEach output channel can be bypassed by repositioning the fuse or circuit breaker. This means that each circuit can be operated manually in the event of a system failure. The protection provided by the circuit breaker or fuse remains intact.\u003c\/p\u003e\n\u003cp\u003eDelivery includes M12-T cable.\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eRequires PSL from version 1.3.0 and PSM2 from version 8B\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCMR 232\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(fuse)\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\/ CMR 232S\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(with circuit breakers)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSwitching channels:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                            2 (2-pole)                \u003cbr\u003e\u003cb\u003eCurrent load per channel:\u003c\/b\u003e           30 A\u003cbr\u003e\u003cb\u003eInputs:                                                   \u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                           W 140 x L 180 x H 50 mm \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Security","offer_id":52832136626513,"sku":"071000232","price":295.0,"currency_code":"EUR","in_stock":true},{"title":"vending machine","offer_id":53259342938449,"sku":"071001232","price":355.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000232_CMR.png?v=1776241074"},{"product_id":"cmr-411-s","title":"P-Bus Relay Module CMR 411 S","description":"\u003cp\u003e\u003cb\u003eDIGITAL SWITCHING AND CONTROL VIA PSM AND PSL\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe new relay module allows for the fused switching of 4 loads, up to a maximum of 10A, via the integrated fuse or circuit breaker. Potential-free switching is also possible. The respective channel can also be switched via a button using the digital switching input on the CMR.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntegrated Emergency Operation:\u003c\/b\u003e\u003cbr\u003eEach output channel can be bypassed by repositioning the fuse or circuit breaker. This means that every circuit can be operated manually in the event of a system failure. The protection provided by the circuit breaker or fuse is maintained.\u003c\/p\u003e\n\u003cp\u003eDelivery includes M12-T cable.\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eRequires PSL from version 1.3.0 and PSM2 from version 8B\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCMR 411\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(fuse)\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\/ CMR 411S\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(with circuit breakers)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSwitching channels:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                            4 (1-pole)                \u003cbr\u003e\u003cb\u003eCurrent load per channel:\u003c\/b\u003e           10 A\u003cbr\u003e\u003cb\u003eInputs:                                              \u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e4\u003cbr\u003e\u003cb\u003eAdditional function:   \u003c\/b\u003e                        4 PWM dimmers \u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                           B 140 x L 120 x H 50 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Security","offer_id":52832137085265,"sku":"071000411","price":209.0,"currency_code":"EUR","in_stock":true},{"title":"vending machine","offer_id":53259342479697,"sku":"071001411","price":269.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000411.png?v=1768491135"},{"product_id":"cmr-412-s","title":"P-Bus Relay Module CMR 412 S","description":"\u003cp\u003e\u003cb\u003eDIGITAL SWITCHING AND CONTROL VIA PSM AND PSL\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe new relay module allows for the fused switching of 2-pole systems with 4 consumers, up to a maximum of 10A, via the integrated fuse or circuit breaker. Potential-free switching is also possible. Additionally, each channel can be switched via a button using the digital switching input on the CMR.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntegrated emergency operation:\u003c\/b\u003e\u003cbr\u003eEach output channel can be bypassed by repositioning the fuse or circuit breaker. This allows each circuit to be operated manually in the event of a system failure. The protection provided by the circuit breaker or fuse remains active.\u003c\/p\u003e\n\u003cp\u003eSupplied incl. M12-T cable.\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eRequires PSL from version 1.3.0 and PSM2 from version 8B\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCMR 412\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(fuse)\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\/ CMR 412S\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(with circuit breakers)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSwitching channels:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                            4 (2-pole)                \u003cbr\u003e\u003cb\u003eCurrent load per channel:\u003c\/b\u003e           10 A\u003cbr\u003e\u003cb\u003eInputs:                                      \u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e4\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eAdditional function: \u003c\/b\u003e                             4 PWM dimmers\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                           W 140 x L 180 x H 50 mm \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Security","offer_id":52832137314641,"sku":"071000412","price":315.0,"currency_code":"EUR","in_stock":true},{"title":"vending machine","offer_id":53259342414161,"sku":"071001412","price":449.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000412_CMR.png?v=1776242697"},{"product_id":"cmr-431-s","title":"P-Bus Relay Module CMR 431 S","description":"\u003cp\u003e\u003cb\u003eDIGITAL SWITCHING AND CONTROL VIA PSM AND PSL\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe new relay module enables the fused switching of 4 consumers with a maximum of 30A via the integrated fuse or circuit breaker. \u003cbr\u003eThe respective channel can also be switched via a push button using the digital switching input on the CMR.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntegrated emergency operation:\u003c\/b\u003e\u003cbr\u003eEach output channel can be bypassed by repositioning the fuse or circuit breaker. This means that each circuit can be operated manually in the event of a system failure. The protection provided by the circuit breaker or fuse is retained.\u003c\/p\u003e\n\u003cp\u003eDelivered with M12 T-cable. \u003cb\u003eRequires PSL from version 1.3.0 and PSM2 from version 8B\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCMR 431 \u003c\/b\u003e(fuse)\u003cb\u003e \/ CMR 431S \u003c\/b\u003e(with circuit breakers)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSwitching channels:\u003c\/b\u003e 4 (1-pole) \u003cbr\u003e\u003cb\u003eCurrent load per channel:\u003c\/b\u003e 30 A\u003cbr\u003e\u003cb\u003eInputs:\u003c\/b\u003e 4\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e W 140 x L 180 x H 50 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Security","offer_id":52832137544017,"sku":"071000431","price":295.0,"currency_code":"EUR","in_stock":true},{"title":"vending machine","offer_id":53259342348625,"sku":"071001431","price":355.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000431_CMR.png?v=1776242999"},{"product_id":"cmr-811-s","title":"P-Bus Relay Module CMR 811 S","description":"\u003cp\u003e\u003cb\u003eDIGITAL SWITCHING AND CONTROL VIA PSM AND PSL\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe new relay module allows for the fused switching of 8 loads up to a maximum of 10A via the integrated fuse or circuit breaker. Potential-free switching is also possible. Via the digital switching input on the CMR, the respective channel can also be switched using a push-button.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntegrated emergency operation:\u003c\/b\u003e\u003cbr\u003eEach output channel can be bypassed by repositioning the fuse or circuit breaker. This means that each circuit can be manually operated in the event of a system failure. The protection provided by the circuit breaker or fuse is maintained.\u003c\/p\u003e\n\u003cp\u003eDelivery includes M12-T-cable.\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eRequires PSL from version 1.3.0 and PSM2 from version 8B\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCMR 811\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(fuse)\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\/ CMR 811S\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(with circuit breakers)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSwitching channels:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                            8 (1-pole)                \u003cbr\u003e\u003cb\u003eCurrent load per channel:\u003c\/b\u003e           10 A\u003cbr\u003e\u003cb\u003eInputs:                                              \u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8\u003cbr\u003e\u003cb\u003eAdditional function:   \u003c\/b\u003e                        4 PWM dimmers \u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                           W 140 x L 180 x H 50 mm \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Security","offer_id":52832138363217,"sku":"071000811","price":315.0,"currency_code":"EUR","in_stock":true},{"title":"vending machine","offer_id":53259341955409,"sku":"071001811","price":449.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000811_CMR.png?v=1776243993"},{"product_id":"tsr","title":"Tax Interface TSR","description":"\u003cp\u003e With the help of the TSR control interface, the remotely controlled battery main switch FBR 500 (500A continuous power) can also be used as deep discharge protection.\u003c\/p\u003e\n\n\u003cp\u003e \u003cb\u003eTSR 12V TSR 24V\u003c\/b\u003e\u003cbr\u003e\n \u003cb\u003eNominal voltage:\u003c\/b\u003e 12 V DC 24 V DC\u003cbr\u003e \n\u003cb\u003eSwitching capacity:\u003c\/b\u003e over FBR 500\u003cbr\u003e\n \u003cb\u003eCut-off voltage:\u003c\/b\u003e 11.2 V \/ 22.4 V @300 s\u003cbr\u003e\n \u003cb\u003eRestart voltage:\u003c\/b\u003e 12.5 V \/ 25 V\u003cbr\u003e\n \u003cb\u003eOvervoltage shutdown:\u003c\/b\u003e 15.6 V \/ 31.2 V @60 s\u003cbr\u003e\n \u003cb\u003eSelf-consumption:\u003c\/b\u003e 1.3 mA 2 mA\u003cbr\u003e\n \u003cb\u003eDimensions:\u003c\/b\u003e L 120 x W 110 x H 50 mm\u003c\/p\u003e\n\n\u003cp\u003e \u003ca href=\"\/wp-content\/uploads\/philippi\/Info\/philippi20DE-TIEFLADESCHUTZ.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFurther information\u003c\/a\u003e\u003c\/p\u003e\n\n","brand":"philippi","offers":[{"title":"DC12V","offer_id":52832140558673,"sku":"083010100","price":89.0,"currency_code":"EUR","in_stock":true},{"title":"DC24V","offer_id":53258901684561,"sku":"083020100","price":89.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/083010100_TSR.png?v=1776322611"},{"product_id":"thr-265","title":"Remote-controlled power deep discharge protection THR 265","description":"\u003cp\u003eThe remote-controlled high-power deep discharge protection THR 265 is suitable for switching off the entire electrical system or the DC input of inverters. An optical pre-warning on the optional control panel FAR indicates an impending emergency shutdown when the lower voltage limit is reached. The electrical system can also be switched on and off remotely. Reconnection occurs automatically at 12.5\/25V. The very low power consumption does not place an additional load on the battery to be protected. The relay can be emergency-operated via a short control cable at the front relay terminals.\u003c\/p\u003e\n\u003cp\u003e                                              \u003cb\u003e\u003cspan\u003e \u003c\/span\u003eTHR 265 – 12 V                     THR 265 – 24 V\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eRated voltage:\u003c\/b\u003e                            12 V DC                                     24 V DC\u003cbr\u003e\u003cb\u003eSwitching capacity:\u003c\/b\u003e                             260 A                                        260 A\u003cbr\u003e\u003cb\u003eCut-off voltage: \u003c\/b\u003e                                   11.2 V \/ 22.4 V @300 s  \u003cbr\u003e\u003cb\u003eReconnect voltage:\u003c\/b\u003e                                   12.5 V \/ 25 V\u003cbr\u003e\u003cb\u003eOvervoltage shutdown:\u003c\/b\u003e                       15.6 V \/ 31.2 V @60 s\u003cbr\u003e\u003cb\u003eSelf-consumption:\u003c\/b\u003e                   1.3 mA                                       2 mA  \u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003e                                           L 124 x W 95 x H 50 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"DC12V","offer_id":52832140853585,"sku":"083012675","price":189.0,"currency_code":"EUR","in_stock":true},{"title":"DC24V","offer_id":53259340480849,"sku":"083022675","price":199.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/083022675_THR.png?v=1776323429"},{"product_id":"utv","title":"Non-Contact Level Measurement UTV","description":"\u003cp\u003eNon-contact tank level measurement using ultrasound technology no longer requires moving parts in the tank that can become dirty or be damaged by force. This makes it suitable for measurement in wastewater and faeces tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eInput voltage:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e    10 – 30 V\u003cbr\u003e\u003cb\u003eCurrent consumption:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e        50 mA\u003cbr\u003e\u003cb\u003eOutput signal:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e         0.5 V – 2.5 V\u003cbr\u003e\u003cb\u003eDuty cycle:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e          5 s (first measurement)\u003cbr\u003e\u003cb\u003eAveraging time:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e           50 s  \u003cbr\u003e\u003cb\u003eTemperature range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e   -40°C to +85°C\u003c\/p\u003e","brand":"philippi","offers":[{"title":"20cm","offer_id":52832141803857,"sku":"702193520","price":115.0,"currency_code":"EUR","in_stock":true},{"title":"25cm","offer_id":53258903585105,"sku":"702193525","price":109.0,"currency_code":"EUR","in_stock":true},{"title":"30cm","offer_id":53258903617873,"sku":"702193530","price":109.0,"currency_code":"EUR","in_stock":true},{"title":"35cm","offer_id":53258903650641,"sku":"702193535","price":109.0,"currency_code":"EUR","in_stock":true},{"title":"40cm","offer_id":53258903683409,"sku":"702193540","price":109.0,"currency_code":"EUR","in_stock":true},{"title":"45cm","offer_id":53258903716177,"sku":"702193545","price":109.0,"currency_code":"EUR","in_stock":true},{"title":"50cm","offer_id":53258903748945,"sku":"702193550","price":109.0,"currency_code":"EUR","in_stock":true},{"title":"60cm","offer_id":53258903781713,"sku":"702193560","price":109.0,"currency_code":"EUR","in_stock":true},{"title":"70cm","offer_id":53258903814481,"sku":"702193570","price":109.0,"currency_code":"EUR","in_stock":true},{"title":"80cm","offer_id":53258903847249,"sku":"702193580","price":109.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/702193520_UTV.png?v=1776324283"},{"product_id":"uft","title":"Acoustic Guidance Tube UFT","description":"\u003cp\u003eNo measurement is possible when tilted or when driving in rough seas. By installing a UFT sound guide tube, the measurement is significantly improved. The sound guide tube also protects against dirt or foam on the liquid surface, which can impair the measurement. When used in stainless steel tanks, the sound guide tube also serves to decouple from the sensor.\u003c\/p\u003e\n\u003cp\u003eLength 400 or 800 mm (the tube can be cut to any length).\u003cbr\u003eOverall height 6 mm.\u003c\/p\u003e\n\u003cp\u003eDelivery with seal\u003c\/p\u003e","brand":"philippi","offers":[{"title":"40cm","offer_id":52832142328145,"sku":"702199400","price":24.5,"currency_code":"EUR","in_stock":true},{"title":"80cm","offer_id":53259339792721,"sku":"702199800","price":27.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/702199400_UFT.png?v=1776324571"},{"product_id":"m12-4t-stueck-4-fach","title":"M12 T-splitter 4-way","description":"\u003cp\u003eM12 (NMEA2000) 4-Way T-Connector\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"2-fach","offer_id":53420259049809,"sku":"504111144","price":36.8,"currency_code":"EUR","in_stock":true},{"title":"4-fach","offer_id":53420259082577,"sku":"504111145","price":62.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111145_M12.png?v=1776324912"},{"product_id":"m12-t-stueck","title":"M12 T-piece","description":"\u003cp\u003eM12 (NMEA2000) T-Connector\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832143212881,"sku":"504111149","price":23.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111149_M12_e2d20107-d0e8-4fd6-a9fa-1bc5a4728362.png?v=1776325258"},{"product_id":"fuel-water-52","title":"Round Measuring Instrument Fuel \/ Water 52mm","description":"\u003cp\u003eAnalog round measuring instrument Ø 52mm:\u003cbr\u003e – Fuel for TGT series tank sensors\u003cbr\u003e – Water for TGW series tank sensors\u003c\/p\u003e\n\u003cp\u003eFor operation on 12 V DC.\u003c\/p\u003e\n\u003cp\u003eOperation on 24 V DC only via a series resistor\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.philippi-online.de\/produkt\/vorwiderstand-rturo\/\"\u003e\"Rturo\"\u003c\/a\u003e \u003c\/p\u003e","brand":"turotest","offers":[{"title":"Fuel","offer_id":52832150258001,"sku":"207780541","price":56.0,"currency_code":"EUR","in_stock":true},{"title":"Water","offer_id":53258896769361,"sku":"207780601","price":56.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/207780541_Fuel-Water.png?v=1776422673"},{"product_id":"shp-300","title":"Digital Shunt SHP 348","description":"\u003cp\u003eDigital current shunt for installation in the negative line of the charging source.\u003cbr\u003eThe SHP 348 shunt supplements the BTM2, BLM2, and LTM monitors with an additional current measurement (solar).\u003c\/p\u003e\n\u003cp\u003eSuitable for continuous currents up to 300 A.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent carrying capacity:\u003c\/b\u003e 300A, 600A 1min, 1500A 0.5s\u003cbr\u003e\u003cb\u003eCurrent consumption:\u003c\/b\u003e 10 mA@12 V, 5 mA@24 V\u003cbr\u003e\u003cb\u003eOperating voltage:\u003c\/b\u003e DC 8-40 V\u003cbr\u003e\u003cb\u003eMeasurement range:\u003c\/b\u003e 10 mA - 1500 A\u003cbr\u003e\u003cb\u003eConnection:\u003c\/b\u003e M8 bolt\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 118 x W 40 x H 65 mm\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832150520145,"sku":"070030351","price":119.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/070030351_Shunt_SHP348_a4b857a3-e4e9-452d-9a47-9298d5450127.png?v=1775737642"},{"product_id":"m12-kabelstecker-kabeldose-konfektionierbar","title":"M12 cable connector \/ cable socket, configurable","description":"\u003cp\u003e\u003cspan\u003eM12 (NMEA2000) field-attachable cable connector\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eM12 (NMEA2000) field-attachable cable receptacle\u003c\/span\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Plug","offer_id":52832151732561,"sku":"404371205","price":16.9,"currency_code":"EUR","in_stock":true},{"title":"can","offer_id":53259332026705,"sku":"404361205","price":17.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/404371205_M12-Kabeldose.png?v=1776424305"},{"product_id":"tan-101","title":"Panel with Rocker Switch TAN 101","description":"\u003cp\u003ePanel with rocker switch (0-1) for a Ø 52 mm round instrument.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e 110 x 72.5 x 40 mm\u003cbr\u003e(90 mm with instrument)\u003ca href=\"\/wp-content\/uploads\/philippi\/Info\/philippi20DE-TANKGEBER.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832152617297,"sku":"028000510","price":23.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/028000510_TAN101.png?v=1776670196"},{"product_id":"m12-rj45","title":"T-adapter M12-RJ45","description":"\u003cp\u003eM12 (NMEA2000) - RJ45, T-adapter with PBUS connector, 20 cm length\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832159859025,"sku":"504111148","price":28.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111148.png?v=1768491168"},{"product_id":"m12-pbus-kabel","title":"M12-PBUS cable","description":"\u003cp\u003e\u003cspan\u003eM12 (NMEA2000) Extension Cable 0.5m\/1m\/2m\/5m\/10m\u003c\/span\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"5m","offer_id":52832160088401,"sku":"504111154","price":42.5,"currency_code":"EUR","in_stock":true},{"title":"2m","offer_id":53259325210961,"sku":"504111153","price":30.9,"currency_code":"EUR","in_stock":true},{"title":"1m","offer_id":53259325243729,"sku":"504111152","price":27.1,"currency_code":"EUR","in_stock":true},{"title":"10m","offer_id":53259325276497,"sku":"504111157","price":62.0,"currency_code":"EUR","in_stock":true},{"title":"0.5m","offer_id":53259325309265,"sku":"504111158","price":24.8,"currency_code":"EUR","in_stock":true},{"title":"3m","offer_id":53259325342033,"sku":"504111143","price":32.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111154_M12PBUS-Kabel.png?v=1776674955"},{"product_id":"gobius-pro-1","title":"Side-Mount Tank Sensor GOBIUS PRO","description":"\u003cp\u003eEach sensor transmits its information to the mobile phone via Bluetooth. Up to eight sensors can be registered per tank. The sensor has 2 switching contacts for controlling, e.g., a remote status display. Available as a set with multiple sensors upon request.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNominal voltage: \u003c\/b\u003e12 V\/24 V\u003cbr\u003e\u003cb\u003eCurrent consumption active:\u003c\/b\u003e 100 mA \/ 10 mA (idle)\u003cbr\u003e\u003cb\u003eOutput signal:\u003c\/b\u003e Switching output, Bluetooth\u003cbr\u003e\u003cb\u003eDimensions sensors:\u003c\/b\u003e H 26 mm, Ø 70 mm\u003ca href=\"\/wp-content\/uploads\/philippi\/Info\/philippi20DE-53.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Gobius","offers":[{"title":"Default Title","offer_id":52832161169745,"sku":"700970481","price":179.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/700970481-Gobiuspro.png?v=1780992810"},{"product_id":"m12-t-adapter","title":"M12 T-adapter","description":"\u003cp\u003eM12 (NMEA2000) T-adapter connection cable with angled socket, 20 cm.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Gerade","offer_id":53420286411089,"sku":"504111146","price":26.5,"currency_code":"EUR","in_stock":true},{"title":"Gewinkelt","offer_id":53420286443857,"sku":"504111159","price":28.9,"currency_code":"EUR","in_stock":true},{"title":"RJ45","offer_id":53420348801361,"sku":"504111150","price":29.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111146_M12-TKabel.png?v=1776678258"},{"product_id":"interface-cbw","title":"P-Bus Interface CBW","description":"\u003cp\u003eThe CBW interface enables mobile access via your smartphone\/tablet to data on batteries, tanks, temperatures, and energy data from e.g. inverters. All data visible on the P-Bus system monitors PSM and PSL are displayed in the app.\u003c\/p\u003e\n\u003cp\u003eThe CBW interface is compatible with all previous P-Bus monitors and interfaces; even systems with the first generation PSM1 can thus be upgraded.\u003c\/p\u003e\n\u003cp\u003eEasy connection to the P-Bus via the included M12 T-cable. The CBW interface also requires its own 12V or 24V power supply, then it will start operating.\u003c\/p\u003e\n\u003cp\u003eThe app can be downloaded from the respective app stores. In case the Bluetooth communication does not run on some Android smartphones, an alternative Android version can be downloaded from our server:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/drive.google.com\/drive\/folders\/1SO5mhWpSB3Kf9scaDO9vrQeecwnvoiT8?usp=sharing\"\u003ehttps:\/\/drive.google.com\/drive\/folders\/1SO5mhWpSB3Kf9scaDO9vrQeecwnvoiT8?usp=sharing\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 107 x W 85 x H 40 mm\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832162185553,"sku":"071005000","price":129.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071005000_CBW.png?v=1775737071"},{"product_id":"vorwiderstand-rturo","title":"Series resistor for round measuring instrument Rturo","description":"\u003cp\u003eSeries resistor for operating FUEL\/WATER 52 tank gauges at 24V DC.\u003c\/p\u003e\n\u003cp\u003eEncapsulated design.\u003c\/p\u003e","brand":"turotest","offers":[{"title":"Default Title","offer_id":52832162775377,"sku":"208002000","price":9.9,"currency_code":"EUR","in_stock":true}]},{"product_id":"n2k-kabel","title":"NMEA2000 Adapter Cable N2K Cable","description":"\u003cp\u003eThe optional NMEA2000 (N2K) adapter cable is used for data transfer into an NMEA2000 network. This allows the information to be displayed on connected NMEA2000 plotters in parallel with the Philippi monitor.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832163004753,"sku":"504111140","price":49.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111140_N2K.png?v=1776679628"},{"product_id":"temp-bt","title":"Temperature sensor TEMP-BT","description":"\u003cp\u003eTemperature sensor for EM-Box \/ SHC \/ TPC 4.\u003cbr\u003eNTC sensor cast in plastic housing, with 2.8m PVC cable.\u003cbr\u003eCan be used for measuring water and air temperatures from \u003cb\u003e-30°C to +70°C\u003c\/b\u003e.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832163037521,"sku":"059003000","price":19.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/059003000_Temp-BT.png?v=1776679709"},{"product_id":"uts-25","title":"Spacer ring UTS 25","description":"\u003cp\u003eSpacer ring for dead zone compensation.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHeight:\u003c\/b\u003e 25mm\u003c\/p\u003e\n\u003cp\u003eSupplied with seal and screws\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832163299665,"sku":"702199025","price":26.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/702199025_Abstandsring.png?v=1776679804"},{"product_id":"current-measurement-shunt-shx-300-l","title":"P-Bus Energy Shunt SHX 300-L","description":"\u003cp\u003eDigital current shunt for installation in the negative line of a charging source or a consumer. Connection is made via the pluggable terminal. M8 connection bolts, M12-T P-bus connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent carrying capacity:\u003c\/strong\u003e 300 A, 600 A 1 min, 1500 A 0.5 s.\u003cbr\u003e\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 20 mA (5 mA sleep-mode)\u003cbr\u003e\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 8 - 32 V\u003cbr\u003e\u003cstrong\u003eMeasurement range:\u003c\/strong\u003e 10 mA - 300 A\u003cbr\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e L 118 x W 40 x H 65 mm\u003ca href=\"\/wp-content\/uploads\/philippi\/Info\/philippi20DE-SHX300-L.pdf%20\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832163430737,"sku":"071000306","price":145.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000306_Shunt_SHX-L_e76b81c1-e154-4dc6-854a-d60eef29dede.png?v=1775737544"},{"product_id":"temp-ht","title":"Temperature sensor Temp-HT","description":"\u003cp\u003eTemperature Sensor for Temperature Interface TPC 4\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNTC sensor encapsulated and electrically isolated in a brass cable lug\u003c\/li\u003e\n\u003cli\u003eHole Ø 4 mm, cable length 32 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCan be used for measuring temperatures from \u003cb\u003e+30°C to +250°C\u003c\/b\u003e.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832163529041,"sku":"059003300","price":20.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/059003300_Temp-HT.png?v=1776680358"},{"product_id":"gwa","title":"Adapter ring GWA","description":"\u003cp\u003eAdapter ring for mounting TGT\/TGW tank sensors on a bolt circle according to SAE standard.\u003c\/p\u003e\n\u003cp\u003eInstallation height: 18 mm.\u003c\/p\u003e\n\u003cp\u003eSupplied with seal and screws.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832163791185,"sku":"660109010","price":29.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/660109010_GWS_fe5029d7-04c6-4ae0-9f21-f99dc698fb99.png?v=1776680740"},{"product_id":"trs-130","title":"Tank sensor for waste water tanks TRS 130","description":"\u003cp\u003eTank sensor for waste tanks for 3\/4 full indication according to the waste tank regulation.\u003c\/p\u003e\n\u003cp\u003eFull indication when the fill level is 80 mm before reaching the top edge of the tank.\u003c\/p\u003e\n\u003cp\u003eIdeal for tank depths of 200 - 400 mm. Sensor length 120 mm.\u003c\/p\u003e\n\u003cp\u003eDeveloped for use with our FAF alarm panel with optical and acoustic alarm indication.\u003c\/p\u003e\n\u003cp\u003eSupplied with flange and gasket\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832164053329,"sku":"660117102","price":81.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/660117102_TRS.png?v=1776681136"},{"product_id":"she-300","title":"LIN-Bus Battery Management Shunt SHE 348","description":"\u003cp\u003eDigital battery management shunt for installation in the negative line of the house battery.\u003cbr\u003eThe SHE 348 shunt is compatible with BTM and BLS monitors.\u003cbr\u003eThe shunt is powered via the voltage measurement line of the house battery.\u003c\/p\u003e\n\u003cp\u003eSuitable for continuous charge or discharge currents up to 300 A and battery capacities up to 1000 Ah\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent carrying capacity:\u003c\/b\u003e 300A, 600A 1min, 1500A 0.5s\u003cbr\u003e\u003cb\u003eCurrent consumption:\u003c\/b\u003e 10 mA@12 V, 5 mA@24 V\u003cbr\u003e\u003cb\u003eOperating voltage:\u003c\/b\u003e DC 8-40 V\u003cbr\u003e\u003cb\u003eMeasuring range:\u003c\/b\u003e 10 mA - 1500 A\u003cbr\u003e\u003cb\u003eConnection:\u003c\/b\u003e M8 bolt\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 118 x W 40 x H 65 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832164184401,"sku":"070030348","price":119.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/070030348_she348_shunt_878b9abb-02aa-418e-94c7-e12a6bf5ea0e.png?v=1775824907"},{"product_id":"trv","title":"Tank Cap TRV","description":"\u003cp\u003eCap for sealing the tank during service work on the sender.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832164315473,"sku":"660119000","price":11.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/660119000_TRV.png?v=1776681325"},{"product_id":"cbn","title":"P-Bus NMEA Interface CBN","description":"\u003cp\u003eTo output the battery, tank, and other P-BUS data from the System Monitor to chartplotters and NMEA2000® compatible devices, an NMEA 2000® Bridge is necessary to convert the data accordingly. The following PGNs are currently supported: 127501, 127505, 127506, 127508, 127744, 127747, 127750. Please check which PGNs your plotter can currently display, as this depends on the manufacturer and software version.\u003c\/p\u003e\n\u003cp\u003eP-BUS - NMEA2000® Interface for connection to the P-Bus via the included M12 T-cable. Another M12 T-cable for connection to the NMEA2000® network is included in the scope of delivery. The CBN is powered via the NMEA2000® network.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eDimensions:\u003c\/b\u003e L 107 x W 85 x H 40 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832164413777,"sku":"071000020","price":209.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000020-CBN.png?v=1781000671"},{"product_id":"tdt-10-250","title":"Screw-in Tank Probe TDT-10-250","description":"\u003cp\u003eThe TDT tank sensor is screwed into a G1\/2\" threaded receptacle near the bottom of the tank. The sensor measures the current fluid level in the tank via the hydrostatic pressure of the fluid.\u003cbr\u003eThe TDT tank sensor is suitable for diesel, water, waste water, and faeces tanks.\u003c\/p\u003e\n\u003cp\u003eThe pressure sensor is used in conjunction with a:\u003cbr\u003e. Tank monitor TCS \/ BTM \/ VTM\u003cbr\u003e. Tank interface CMT 2 (System monitors PSM\/PSL) \u003cbr\u003e. Interface UTI (analogue (round) measuring instruments)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplication:\u003c\/b\u003e Screw-in sensor \u003cbr\u003e\u003cb\u003eConstruction:\u003c\/b\u003e G1\/2\" thread \u003cbr\u003e\u003cb\u003eSensor housing: \u003c\/b\u003e Stainless steel 1.4404 (316 L, V4A) \u003cbr\u003e\u003cb\u003eTank media:\u003c\/b\u003e Diesel, water, waste water, faeces \u003cbr\u003e\u003cb\u003eMeasuring range: \u003c\/b\u003e 0 - 250 mbar \u003cbr\u003e\u003cb\u003eMeasuring resolution:\u003c\/b\u003e 1 cm \u003cbr\u003e\u003cb\u003eMax. tank height:\u003c\/b\u003e 250 cm \u003cbr\u003e\u003cb\u003eOperating temperature range: \u003c\/b\u003e 0 – 85 °C \u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003e L 87, Ø 35 mm \u003cbr\u003e\u003cb\u003eOutput signal: \u003c\/b\u003e DC 4 – 20 mA, 2-wire principle\u003cbr\u003e\u003cb\u003eOperating voltage: \u003c\/b\u003e 10 – 30 V DC via measuring line \u003cbr\u003e\u003cb\u003eWeight: \u003c\/b\u003e approx. 0.2 kg, without cable\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832164446545,"sku":"660200250","price":299.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/660200250_TDT.png?v=1776681427"},{"product_id":"cmb","title":"P.Bus Masterbus Interface CMB","description":"\u003cp\u003eTo integrate Mastervolt devices into the P-Bus, the CMB interface is used. This allows Masterbus data to be displayed on the PSL and PSM SystemMonitors and some settings to be made that are required in daily operation. All Mastervolt devices can be purchased from us.\u003c\/p\u003e\n\u003cp\u003eThe Masterbus Bridge provides data from the following Mastervolt devices:\u003c\/p\u003e\n\u003cp\u003eMasterShunt\u003c\/p\u003e\n\u003cp\u003eLithium battery MLI\u003c\/p\u003e\n\u003cp\u003eCombiMaster\u003c\/p\u003e\n\u003cp\u003eMass Combi Ultra\u003c\/p\u003e\n\u003cp\u003eChargeMaster\u003c\/p\u003e\n\u003cp\u003eChargeMaster plus\u003c\/p\u003e\n\u003cp\u003eMac Plus\u003c\/p\u003e\n\u003cp\u003eSolar Master SCM 60\u003c\/p\u003e\n\u003cp\u003eThe interface is powered via the Masterbus network.\u003cbr\u003eDelivery includes M12 T-piece.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions: \u003c\/b\u003e H 66 x W 78 x D 32 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832164708689,"sku":"071000030","price":379.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000030-CMB.png?v=1781000725"},{"product_id":"cbo-sb","title":"P-Bus-SuperB Interface CBO-SB","description":"\u003cp\u003eThis interface enables access to data on voltage, current charge\/discharge current, and state of charge of SuperB Nomia and Nomada lithium batteries via the P-BUS for data display on the PSL and PSM 2 system monitors. If several batteries are combined into a block, data from individual batteries can be queried in addition to the total data. This makes individual cell voltages and other important data for battery analysis available.\u003c\/p\u003e\n\u003cp\u003eP-BUS - CANopen® interface for connection to the P-Bus via the included M12-T cable. Another M12-T cable for connection to the CANopen® network is included in the scope of delivery. The CBO-SB is powered via the CANopen® network. The interface saves the installation of a shunt.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 107 x W 85 x H 40 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832165036369,"sku":"071000041","price":279.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000041_CBO-SB.png?v=1776693139"},{"product_id":"tpc-4","title":"P-Bus Temperature Interface TPC 4","description":"\u003cp\u003eInterface for 4 Temperature Sensors\u003c\/p\u003e\n\u003cp\u003eWith the TPC 4 temperature interface, important temperature values can be recorded. Up to 4 Temp-HT or Temp-BT temperature sensors can be connected per temperature interface. Up to four TPC 4s can be connected to the P-BUS. Individual limit values can be set for each temperature sensor, which generate an alarm message as soon as the limit values are exceeded or fallen below. Temperature-dependent actions can be switched via the CMR4 relay module.\u003c\/p\u003e\n\u003cp\u003eConnection via pluggable screw terminals.\u003cbr\u003eSupplied with M12 T-cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSupply voltage:\u003c\/b\u003e DC 8-32 V\u003cbr\u003e\u003cb\u003eCurrent consumption:\u003c\/b\u003e 8 mA\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 107 x W 85 x H 40 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832165462353,"sku":"071000104","price":179.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000104_TPC4.png?v=1776694386"},{"product_id":"cav","title":"P-Bus AC Interface CAV","description":"\u003cp\u003eAC interface in DIN rail housing for the P-BUS for measuring an AC phase 230 V \/ 50 Hz\u003c\/p\u003e\n\u003cp\u003eVarious devices are often available for visualizing the energy flow of the electrical AC system, which are already capable of providing data. This data needs to be collected and displayed.\u003c\/p\u003e\n\u003cp\u003eThe following devices already provide P-BUS-compatible AC data:\u003cbr\u003e. ACE series chargers\u003cbr\u003e. Shore power transfer units (LAU)\u003c\/p\u003e\n\u003cp\u003eThe following devices can provide P-BUS-compatible data via an interface:\u003cbr\u003e. Studer X-Tender devices (combi inverters and solar controllers)\u003cbr\u003e. Mastervolt devices (combi inverters)\u003c\/p\u003e\n\u003cp\u003eFor power sources and consumers without a P-BUS connection, an AC interface CAV is installed and configured accordingly.\u003c\/p\u003e\n\u003cp\u003eThe AC interface CAV records current and voltage from 230V AC devices and provides the information to the P-BUS:\u003cbr\u003e. AC system voltage [V]\u003cbr\u003e. AC system current [A]\u003cbr\u003e. Kilowatt hours consumed in kWh since last reset\u003cbr\u003e. Name of the source \/ consumer for unique identification\u003c\/p\u003e\n\u003cp\u003eThe electrical connection is made via screw terminals.\u003c\/p\u003e\n\u003cp\u003eConnection to the P-BUS via an M12 T-cable, which is included in the scope of delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent measurement range:\u003c\/b\u003e 16 A (int. shunt) 100 A (via external converter WAC)\u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003e L 76 x W 53 x H 46 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832165691729,"sku":"071000230","price":179.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000230-CAV.png?v=1781001331"},{"product_id":"shx-348","title":"P-Bus Battery Management Shunt SHX 348","description":"\u003cp\u003eDigital battery management shunt for installation in the negative battery cable\u003c\/p\u003e\n\u003cp\u003eThe SHX battery management shunt precisely measures the current, voltage, and capacity of the connected battery. The galvanically isolated P-BUS allows for the acquisition of battery data even from battery groups isolated from the on-board electrical system (e.g., emergency battery for radio systems or for electric drives). The active SHX shunt calculates the current battery capacity from the continuously measured current and voltage values, and the system monitor displays this in color within the battery symbol.\u003c\/p\u003e\n\u003cp\u003ePower supply is provided via the voltage measurement cable. M8 connection bolts.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent carrying capacity:\u003c\/b\u003e 300A, 600A 1min, 1500A 0.5s\u003cbr\u003e\u003cb\u003eCurrent consumption: \u003c\/b\u003e 20 mA (5 mA sleep-mode)\u003cbr\u003e\u003cb\u003eOperating voltage: \u003c\/b\u003e 8-64 V\u003cbr\u003e\u003cb\u003eMeasurement range: \u003c\/b\u003e 10 mA - 300 A\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 118 x W 40 x H 65 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832165921105,"sku":"071000348","price":145.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000348_Shunt_SHX348_f17dd212-4bc9-4ee8-90ee-a8c7b020805d.png?v=1775737504"},{"product_id":"cmt2","title":"P-Bus Tank Interface CMT3","description":"\u003cp\u003eP-BUS Interface for Integrating up to 4 Tank Sensors\u003c\/p\u003e\n\u003cp\u003eThe CMT2 interface is required to integrate tanks or tank sensors into the P-BUS network. It independently measures up to four different tank sensors and makes this information available to the P-BUS. Parameters such as sensor type, tank size, tank characteristic curve, alarm level, etc., are set via the system monitors \u003cb\u003ePSM2\u003c\/b\u003e and \u003cb\u003ePSL\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp\u003eConnection is made via pluggable screw terminals. Connection to the P-BUS via M12 network connector.\u003c\/p\u003e\n\u003cp\u003eAn M12 T-cable is included in the scope of delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperating voltage:\u003c\/b\u003e DC 8-32 V \u003cbr\u003e\u003cb\u003eCurrent consumption: \u003c\/b\u003e Standby: 7.5mA@13 V \u003cbr\u003eActive: 10 mA @ 13 V\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 107 x W 85 x H 40 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832166216017,"sku":"071000402","price":185.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000401-CMT2.png?v=1776696718"},{"product_id":"shx-648","title":"P-Bus Battery Management Shunt SHX 648","description":"\u003cp\u003eDigital battery management shunt for larger currents \/ consumers. M16 connection bolts. Matching distribution bar SAS4.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eCurrent carrying capacity:\u003c\/b\u003e 600A, 800A 1min, 2500A 0.5s\u003cbr\u003e\u003cb\u003eCurrent consumption: \u003c\/b\u003e 6 mA@12 V, 4 mA@24 V\u003cbr\u003e\u003cb\u003eOperating voltage: \u003c\/b\u003e 8-60 V\u003cbr\u003e\u003cb\u003eMeasurement range: \u003c\/b\u003e 10 mA - 600 A\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 185 x W 44 x H 75 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832166642001,"sku":"071000648","price":279.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000648_Shunt_SHX648_a21f39ec-7ecc-40a1-aab1-cada7787a890.png?v=1775737474"},{"product_id":"dfs-24","title":"Flow Sensor DFS 24","description":"\u003cp\u003eFresh water flow sensor for connection to a digital tank monitor BTM(2), VTM(2) and the tank interface CMT(3).\u003cbr\u003eFlow rate 1-25 l\/min. Connection flange for hose 10-12 mm, cable length 20 cm. Pulse count: 1000 pulses\/L.\u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003eL 110 x W 23 x H 57 mm\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832166904145,"sku":"700030324","price":135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/700030324-DFS24.png?v=1780997661"},{"product_id":"as-100","title":"Acoustic Signal Transmitter AS 100","description":"\u003cp\u003eAudible signal device with mounting tabs.\u003c\/p\u003e\n\u003ctable summary=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e75 dB\/1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e27 x 18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"philippi","offers":[{"title":"DC12V","offer_id":52832166936913,"sku":"603604320","price":11.0,"currency_code":"EUR","in_stock":true},{"title":"DC24V","offer_id":53258883531089,"sku":"603604340","price":11.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/603604320_AS100.png?v=1776697452"},{"product_id":"em-box-v3","title":"Energy Management EM-Box V3","description":"\u003cp\u003eThe Energy Management Box reduces high-current wiring around the engine and battery system to a minimum. It takes over the complete charge and energy management of a modern single-engine yacht with up to 3 battery banks (starter, house, and bow batteries) and additional alternative charging sources (solar, wind, and hydro generators). Even the DC connection of a combi inverter is taken into account.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eThe EM-box integrates:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli\u003e10 high-power shunts\u003c\/li\u003e\n\u003cli\u003eAlternator charge current distributor\u003c\/li\u003e\n\u003cli\u003e3 remote-controlled battery master switches\u003c\/li\u003e\n\u003cli\u003eDeep discharge protection\u003c\/li\u003e\n\u003cli\u003eCharge current distribution for battery charger, solar system, wind generator, hydro generator\u003c\/li\u003e\n\u003cli\u003eGround busbar\u003c\/li\u003e\n\u003cli\u003eMain fuse for the onboard electrical system\u003c\/li\u003e\n\u003cli\u003eEngine emergency start via house battery\u003c\/li\u003e\n\u003cli\u003eManual emergency operation of the main switches\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ci\u003e\u003cb\u003eP-Bus\u003c\/b\u003e\u003c\/i\u003e interface for system monitor PSM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eThe EM-box enables:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eSimple and clear installation\u003c\/li\u003e\n\u003cli\u003eFewer sources of error\u003c\/li\u003e\n\u003cli\u003eSafety through separate positive and negative connections\u003c\/li\u003e\n\u003cli\u003eReduced space requirements\u003c\/li\u003e\n\u003cli\u003eImmediate operation without configuration\u003c\/li\u003e\n\u003cli\u003eLow installation effort\u003c\/li\u003e\n\u003cli\u003eBattery monitoring for all battery banks\u003c\/li\u003e\n\u003cli\u003eRemote control of the master switches\u003c\/li\u003e\n\u003cli\u003eClear DC energy balance\u003c\/li\u003e\n\u003cli\u003eUse for 24 V onboard electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDelivery \u003cb\u003ewithout\u003c\/b\u003e SHB bolt fuses. Please order separately - see Onboard Installation\/Fuses and Accessories.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832167035217,"sku":"071001001","price":1599.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071001001_EMBox.png?v=1776771226"},{"product_id":"dff-1-2","title":"Connection flange DFF 1\/2\"","description":"\u003cp\u003eHose connection flange 1\/2\" 1 pc.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832167067985,"sku":"700039002","price":4.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/700039002-DFF.png?v=1780997814"}],"url":"https:\/\/www.philippi-online.de\/en\/collections\/bordueberwachung.oembed","provider":"philippi elektrische systeme GmbH","version":"1.0","type":"link"}