{"title":"____Bord Überwachung-resevre","description":"","products":[{"product_id":"fhc-265","title":"Remote-controlled P-bus circuit breaker FHC 265","description":"\u003cp\u003eRemote-controlled power disconnect switch with adjustable deep discharge protection and overvoltage shutdown with P-Bus interface.\u003c\/p\u003e\n\u003cp\u003eThe FHC 265 remote-controlled main switch is used for convenient switching of the on-board power supply or the power supply of high-current consumers such as winches, anchor winches, inverters (energy management). The adjustable undervoltage and overvoltage protection simultaneously protects the battery from deep discharge.\u003c\/p\u003e\n\u003cp\u003eFor applications with a continuous current load greater than 260 A (e.g. bow thrusters), a solution with a current carrying capacity of up to 500 A can be provided by combining the TSC interface with the FBR 500.\u003c\/p\u003e\n\u003cp\u003eControl via control button or P-BUS. All settings can be adjusted on the PSM\/PSL.\u003c\/p\u003e\n\u003cp\u003eFor independent operation of the main switch from the P-BUS, we recommend installing an external control button.\u003c\/p\u003e\n\u003cp\u003eAt the relay terminals on the front, the relay can be emergency operated via a short control line.\u003c\/p\u003e\n\u003cp\u003eMounted M12-T cable for easy integration into the P-Bus.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRated voltage:\u003c\/b\u003e 12 + 24 V DC\u003cbr\u003e\u003cb\u003emax. continuous current:\u003c\/b\u003e 260 A\u003cbr\u003e\u003cb\u003eSelf power consumption:\u003c\/b\u003e 2 mA\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 124 x W 95 x H 50 mm\u003ca aria-label=\"Weitere Informationen\" href=\"\/wp-content\/uploads\/philippi\/Info\/philippi20DE-PBUS_FERNSTEUERBARE.pdf%20\" tabindex=\"-1\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832126599505,"sku":"083022720","price":229.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/083022770_FHC.png?v=1775827091"},{"product_id":"fhc-265-bipolar","title":"Remote-controlled P-bus circuit breaker FHC 265 Bipolar","description":"\u003cp\u003e2-pole version of the remote-controlled battery disconnect switch FBC. Manual emergency operation directly at the relays is possible.\u003cbr\u003eDelivery includes M12 T-cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRated voltage:\u003c\/b\u003e 12 + 24 V DC\u003cbr\u003e\u003cb\u003eMax. continuous current:\u003c\/b\u003e 2x 260 A\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.philippi-online.de\/wp-content\/uploads\/2024\/03\/TSC_V2E-D.pdf\" rel=\"noopener\" tabindex=\"-1\" target=\"_blank\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832126796113,"sku":"083022755","price":399.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/083022755_FHC-BI.png?v=1775828486"},{"product_id":"xcom-can","title":"P-BUS-Studer Bridge XCOM-CAN","description":"\u003cp\u003eThe Xcom CAN Bridge is required to display data from the Xtender inverter\/chargers and to configure settings from the system monitor. Power is supplied via the Xtender network.\u003cbr\u003eIncludes M12 T-cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 113 x W 76 x H 25 mm\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"studer","offers":[{"title":"Default Title","offer_id":52832127091025,"sku":"700069042","price":379.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/700069042-xcom-can.png?v=1780997889"},{"product_id":"cmr-232-s","title":"P-Bus Relay Module CMR 232 S","description":"\u003cp\u003e\u003cb\u003eDIGITAL SWITCHING AND CONTROL VIA PSM AND PSL\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe new relay module enables the fused switching of 2-pole systems with 2 consumers, up to a maximum of 30A via the integrated fuse or circuit breaker.\u003cbr\u003eVia the digital switching input on the CMR, the respective channel can also be switched by means of a button.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntegrated emergency operation:\u003c\/b\u003e\u003cbr\u003eEach output channel can be bypassed by repositioning the fuse or circuit breaker. This means that each circuit can be operated manually in the event of a system failure. The protection provided by the circuit breaker or fuse remains intact.\u003c\/p\u003e\n\u003cp\u003eDelivery includes M12-T cable.\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eRequires PSL from version 1.3.0 and PSM2 from version 8B\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCMR 232\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(fuse)\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\/ CMR 232S\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(with circuit breakers)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSwitching channels:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                            2 (2-pole)                \u003cbr\u003e\u003cb\u003eCurrent load per channel:\u003c\/b\u003e           30 A\u003cbr\u003e\u003cb\u003eInputs:                                                   \u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                           W 140 x L 180 x H 50 mm \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Security","offer_id":52832136626513,"sku":"071000232","price":295.0,"currency_code":"EUR","in_stock":true},{"title":"vending machine","offer_id":53259342938449,"sku":"071001232","price":355.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000232_CMR.png?v=1776241074"},{"product_id":"cmr-411-s","title":"P-Bus Relay Module CMR 411 S","description":"\u003cp\u003e\u003cb\u003eDIGITAL SWITCHING AND CONTROL VIA PSM AND PSL\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe new relay module allows for the fused switching of 4 loads, up to a maximum of 10A, via the integrated fuse or circuit breaker. Potential-free switching is also possible. The respective channel can also be switched via a button using the digital switching input on the CMR.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntegrated Emergency Operation:\u003c\/b\u003e\u003cbr\u003eEach output channel can be bypassed by repositioning the fuse or circuit breaker. This means that every circuit can be operated manually in the event of a system failure. The protection provided by the circuit breaker or fuse is maintained.\u003c\/p\u003e\n\u003cp\u003eDelivery includes M12-T cable.\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eRequires PSL from version 1.3.0 and PSM2 from version 8B\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCMR 411\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(fuse)\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\/ CMR 411S\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(with circuit breakers)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSwitching channels:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                            4 (1-pole)                \u003cbr\u003e\u003cb\u003eCurrent load per channel:\u003c\/b\u003e           10 A\u003cbr\u003e\u003cb\u003eInputs:                                              \u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e4\u003cbr\u003e\u003cb\u003eAdditional function:   \u003c\/b\u003e                        4 PWM dimmers \u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                           B 140 x L 120 x H 50 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Security","offer_id":52832137085265,"sku":"071000411","price":209.0,"currency_code":"EUR","in_stock":true},{"title":"vending machine","offer_id":53259342479697,"sku":"071001411","price":269.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000411.png?v=1768491135"},{"product_id":"cmr-412-s","title":"P-Bus Relay Module CMR 412 S","description":"\u003cp\u003e\u003cb\u003eDIGITAL SWITCHING AND CONTROL VIA PSM AND PSL\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe new relay module allows for the fused switching of 2-pole systems with 4 consumers, up to a maximum of 10A, via the integrated fuse or circuit breaker. Potential-free switching is also possible. Additionally, each channel can be switched via a button using the digital switching input on the CMR.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntegrated emergency operation:\u003c\/b\u003e\u003cbr\u003eEach output channel can be bypassed by repositioning the fuse or circuit breaker. This allows each circuit to be operated manually in the event of a system failure. The protection provided by the circuit breaker or fuse remains active.\u003c\/p\u003e\n\u003cp\u003eSupplied incl. M12-T cable.\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eRequires PSL from version 1.3.0 and PSM2 from version 8B\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCMR 412\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(fuse)\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\/ CMR 412S\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(with circuit breakers)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSwitching channels:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                            4 (2-pole)                \u003cbr\u003e\u003cb\u003eCurrent load per channel:\u003c\/b\u003e           10 A\u003cbr\u003e\u003cb\u003eInputs:                                      \u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e4\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eAdditional function: \u003c\/b\u003e                             4 PWM dimmers\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                           W 140 x L 180 x H 50 mm \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Security","offer_id":52832137314641,"sku":"071000412","price":315.0,"currency_code":"EUR","in_stock":true},{"title":"vending machine","offer_id":53259342414161,"sku":"071001412","price":449.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000412_CMR.png?v=1776242697"},{"product_id":"cmr-431-s","title":"P-Bus Relay Module CMR 431 S","description":"\u003cp\u003e\u003cb\u003eDIGITAL SWITCHING AND CONTROL VIA PSM AND PSL\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe new relay module enables the fused switching of 4 consumers with a maximum of 30A via the integrated fuse or circuit breaker. \u003cbr\u003eThe respective channel can also be switched via a push button using the digital switching input on the CMR.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntegrated emergency operation:\u003c\/b\u003e\u003cbr\u003eEach output channel can be bypassed by repositioning the fuse or circuit breaker. This means that each circuit can be operated manually in the event of a system failure. The protection provided by the circuit breaker or fuse is retained.\u003c\/p\u003e\n\u003cp\u003eDelivered with M12 T-cable. \u003cb\u003eRequires PSL from version 1.3.0 and PSM2 from version 8B\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCMR 431 \u003c\/b\u003e(fuse)\u003cb\u003e \/ CMR 431S \u003c\/b\u003e(with circuit breakers)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSwitching channels:\u003c\/b\u003e 4 (1-pole) \u003cbr\u003e\u003cb\u003eCurrent load per channel:\u003c\/b\u003e 30 A\u003cbr\u003e\u003cb\u003eInputs:\u003c\/b\u003e 4\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e W 140 x L 180 x H 50 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Security","offer_id":52832137544017,"sku":"071000431","price":295.0,"currency_code":"EUR","in_stock":true},{"title":"vending machine","offer_id":53259342348625,"sku":"071001431","price":355.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000431_CMR.png?v=1776242999"},{"product_id":"cmr-811-s","title":"P-Bus Relay Module CMR 811 S","description":"\u003cp\u003e\u003cb\u003eDIGITAL SWITCHING AND CONTROL VIA PSM AND PSL\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe new relay module allows for the fused switching of 8 loads up to a maximum of 10A via the integrated fuse or circuit breaker. Potential-free switching is also possible. Via the digital switching input on the CMR, the respective channel can also be switched using a push-button.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntegrated emergency operation:\u003c\/b\u003e\u003cbr\u003eEach output channel can be bypassed by repositioning the fuse or circuit breaker. This means that each circuit can be manually operated in the event of a system failure. The protection provided by the circuit breaker or fuse is maintained.\u003c\/p\u003e\n\u003cp\u003eDelivery includes M12-T-cable.\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eRequires PSL from version 1.3.0 and PSM2 from version 8B\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCMR 811\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(fuse)\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\/ CMR 811S\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(with circuit breakers)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSwitching channels:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                            8 (1-pole)                \u003cbr\u003e\u003cb\u003eCurrent load per channel:\u003c\/b\u003e           10 A\u003cbr\u003e\u003cb\u003eInputs:                                              \u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8\u003cbr\u003e\u003cb\u003eAdditional function:   \u003c\/b\u003e                        4 PWM dimmers \u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e                           W 140 x L 180 x H 50 mm \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Security","offer_id":52832138363217,"sku":"071000811","price":315.0,"currency_code":"EUR","in_stock":true},{"title":"vending machine","offer_id":53259341955409,"sku":"071001811","price":449.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000811_CMR.png?v=1776243993"},{"product_id":"til-til-2","title":"Tank interface (TIL \/ TIL #2)","description":"\u003cp\u003eThe TIL tank interface adapts the signals from two fresh water and one waste water rod probes to the BTM battery tank monitor (included).\u003c\/p\u003e\n\u003cp\u003eThe TIL #2 tank interface is additionally required if two waste water tanks are installed on board the Bavaria.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperating voltage\u003c\/b\u003e: 10-32V DC\u003cbr\u003e\u003cb\u003eCurrent consumption\u003c\/b\u003e: 10 mA\u003cbr\u003e\u003cb\u003eDimensions\u003c\/b\u003e: W 130 x H 80 x D 42 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Tank 1-3","offer_id":52832138756433,"sku":"080001550","price":89.0,"currency_code":"EUR","in_stock":true},{"title":"Tank 4","offer_id":53258901651793,"sku":"080001552","price":89.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/080001550_TIL.png?v=1778242235"},{"product_id":"m12-4t-stueck-4-fach","title":"M12 T-splitter 4-way","description":"\u003cp\u003eM12 (NMEA2000) 4-Way T-Connector\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"2-fach","offer_id":53420259049809,"sku":"504111144","price":36.8,"currency_code":"EUR","in_stock":true},{"title":"4-fach","offer_id":53420259082577,"sku":"504111145","price":62.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111145_M12.png?v=1776324912"},{"product_id":"m12-t-stueck","title":"M12 T-piece","description":"\u003cp\u003eM12 (NMEA2000) T-Connector\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832143212881,"sku":"504111149","price":23.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111149_M12_e2d20107-d0e8-4fd6-a9fa-1bc5a4728362.png?v=1776325258"},{"product_id":"shp-300","title":"Digital Shunt SHP 348","description":"\u003cp\u003eDigital current shunt for installation in the negative line of the charging source.\u003cbr\u003eThe SHP 348 shunt supplements the BTM2, BLM2, and LTM monitors with an additional current measurement (solar).\u003c\/p\u003e\n\u003cp\u003eSuitable for continuous currents up to 300 A.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent carrying capacity:\u003c\/b\u003e 300A, 600A 1min, 1500A 0.5s\u003cbr\u003e\u003cb\u003eCurrent consumption:\u003c\/b\u003e 10 mA@12 V, 5 mA@24 V\u003cbr\u003e\u003cb\u003eOperating voltage:\u003c\/b\u003e DC 8-40 V\u003cbr\u003e\u003cb\u003eMeasurement range:\u003c\/b\u003e 10 mA - 1500 A\u003cbr\u003e\u003cb\u003eConnection:\u003c\/b\u003e M8 bolt\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 118 x W 40 x H 65 mm\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832150520145,"sku":"070030351","price":119.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/070030351_Shunt_SHP348_a4b857a3-e4e9-452d-9a47-9298d5450127.png?v=1775737642"},{"product_id":"m12-kabelstecker-kabeldose-konfektionierbar","title":"M12 cable connector \/ cable socket, configurable","description":"\u003cp\u003e\u003cspan\u003eM12 (NMEA2000) field-attachable cable connector\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eM12 (NMEA2000) field-attachable cable receptacle\u003c\/span\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Plug","offer_id":52832151732561,"sku":"404371205","price":16.9,"currency_code":"EUR","in_stock":true},{"title":"can","offer_id":53259332026705,"sku":"404361205","price":17.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/404371205_M12-Kabeldose.png?v=1776424305"},{"product_id":"m12-pbus-kabel","title":"M12-PBUS cable","description":"\u003cp\u003e\u003cspan\u003eM12 (NMEA2000) Extension Cable 0.5m\/1m\/2m\/5m\/10m\u003c\/span\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"5m","offer_id":52832160088401,"sku":"504111154","price":42.5,"currency_code":"EUR","in_stock":true},{"title":"2m","offer_id":53259325210961,"sku":"504111153","price":30.9,"currency_code":"EUR","in_stock":true},{"title":"1m","offer_id":53259325243729,"sku":"504111152","price":27.1,"currency_code":"EUR","in_stock":true},{"title":"10m","offer_id":53259325276497,"sku":"504111157","price":62.0,"currency_code":"EUR","in_stock":true},{"title":"0.5m","offer_id":53259325309265,"sku":"504111158","price":24.8,"currency_code":"EUR","in_stock":true},{"title":"3m","offer_id":53259325342033,"sku":"504111143","price":32.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111154_M12PBUS-Kabel.png?v=1776674955"},{"product_id":"interface-cbw","title":"P-Bus Interface CBW","description":"\u003cp\u003eThe CBW interface enables mobile access via your smartphone\/tablet to data on batteries, tanks, temperatures, and energy data from e.g. inverters. All data visible on the P-Bus system monitors PSM and PSL are displayed in the app.\u003c\/p\u003e\n\u003cp\u003eThe CBW interface is compatible with all previous P-Bus monitors and interfaces; even systems with the first generation PSM1 can thus be upgraded.\u003c\/p\u003e\n\u003cp\u003eEasy connection to the P-Bus via the included M12 T-cable. The CBW interface also requires its own 12V or 24V power supply, then it will start operating.\u003c\/p\u003e\n\u003cp\u003eThe app can be downloaded from the respective app stores. In case the Bluetooth communication does not run on some Android smartphones, an alternative Android version can be downloaded from our server:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/drive.google.com\/drive\/folders\/1SO5mhWpSB3Kf9scaDO9vrQeecwnvoiT8?usp=sharing\"\u003ehttps:\/\/drive.google.com\/drive\/folders\/1SO5mhWpSB3Kf9scaDO9vrQeecwnvoiT8?usp=sharing\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 107 x W 85 x H 40 mm\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832162185553,"sku":"071005000","price":129.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071005000_CBW.png?v=1775737071"},{"product_id":"n2k-kabel","title":"NMEA2000 Adapter Cable N2K Cable","description":"\u003cp\u003eThe optional NMEA2000 (N2K) adapter cable is used for data transfer into an NMEA2000 network. This allows the information to be displayed on connected NMEA2000 plotters in parallel with the Philippi monitor.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832163004753,"sku":"504111140","price":49.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111140_N2K.png?v=1776679628"},{"product_id":"current-measurement-shunt-shx-300-l","title":"P-Bus Energy Shunt SHX 300-L","description":"\u003cp\u003eDigital current shunt for installation in the negative line of a charging source or a consumer. Connection is made via the pluggable terminal. M8 connection bolts, M12-T P-bus connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent carrying capacity:\u003c\/strong\u003e 300 A, 600 A 1 min, 1500 A 0.5 s.\u003cbr\u003e\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 20 mA (5 mA sleep-mode)\u003cbr\u003e\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 8 - 32 V\u003cbr\u003e\u003cstrong\u003eMeasurement range:\u003c\/strong\u003e 10 mA - 300 A\u003cbr\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e L 118 x W 40 x H 65 mm\u003ca href=\"\/wp-content\/uploads\/philippi\/Info\/philippi20DE-SHX300-L.pdf%20\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832163430737,"sku":"071000306","price":145.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000306_Shunt_SHX-L_e76b81c1-e154-4dc6-854a-d60eef29dede.png?v=1775737544"},{"product_id":"temp-ht","title":"Temperature sensor Temp-HT","description":"\u003cp\u003eTemperature Sensor for Temperature Interface TPC 4\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNTC sensor encapsulated and electrically isolated in a brass cable lug\u003c\/li\u003e\n\u003cli\u003eHole Ø 4 mm, cable length 32 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCan be used for measuring temperatures from \u003cb\u003e+30°C to +250°C\u003c\/b\u003e.\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832163529041,"sku":"059003300","price":20.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/059003300_Temp-HT.png?v=1776680358"},{"product_id":"she-300","title":"LIN-Bus Battery Management Shunt SHE 348","description":"\u003cp\u003eDigital battery management shunt for installation in the negative line of the house battery.\u003cbr\u003eThe SHE 348 shunt is compatible with BTM and BLS monitors.\u003cbr\u003eThe shunt is powered via the voltage measurement line of the house battery.\u003c\/p\u003e\n\u003cp\u003eSuitable for continuous charge or discharge currents up to 300 A and battery capacities up to 1000 Ah\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent carrying capacity:\u003c\/b\u003e 300A, 600A 1min, 1500A 0.5s\u003cbr\u003e\u003cb\u003eCurrent consumption:\u003c\/b\u003e 10 mA@12 V, 5 mA@24 V\u003cbr\u003e\u003cb\u003eOperating voltage:\u003c\/b\u003e DC 8-40 V\u003cbr\u003e\u003cb\u003eMeasuring range:\u003c\/b\u003e 10 mA - 1500 A\u003cbr\u003e\u003cb\u003eConnection:\u003c\/b\u003e M8 bolt\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 118 x W 40 x H 65 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832164184401,"sku":"070030348","price":119.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/070030348_she348_shunt_878b9abb-02aa-418e-94c7-e12a6bf5ea0e.png?v=1775824907"},{"product_id":"cbn","title":"P-Bus NMEA Interface CBN","description":"\u003cp\u003eTo output the battery, tank, and other P-BUS data from the System Monitor to chartplotters and NMEA2000® compatible devices, an NMEA 2000® Bridge is necessary to convert the data accordingly. The following PGNs are currently supported: 127501, 127505, 127506, 127508, 127744, 127747, 127750. Please check which PGNs your plotter can currently display, as this depends on the manufacturer and software version.\u003c\/p\u003e\n\u003cp\u003eP-BUS - NMEA2000® Interface for connection to the P-Bus via the included M12 T-cable. Another M12 T-cable for connection to the NMEA2000® network is included in the scope of delivery. The CBN is powered via the NMEA2000® network.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eDimensions:\u003c\/b\u003e L 107 x W 85 x H 40 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832164413777,"sku":"071000020","price":209.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000020-CBN.png?v=1781000671"},{"product_id":"tdt-10-250","title":"Screw-in Tank Probe TDT-10-250","description":"\u003cp\u003eThe TDT tank sensor is screwed into a G1\/2\" threaded receptacle near the bottom of the tank. The sensor measures the current fluid level in the tank via the hydrostatic pressure of the fluid.\u003cbr\u003eThe TDT tank sensor is suitable for diesel, water, waste water, and faeces tanks.\u003c\/p\u003e\n\u003cp\u003eThe pressure sensor is used in conjunction with a:\u003cbr\u003e. Tank monitor TCS \/ BTM \/ VTM\u003cbr\u003e. Tank interface CMT 2 (System monitors PSM\/PSL) \u003cbr\u003e. Interface UTI (analogue (round) measuring instruments)\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplication:\u003c\/b\u003e Screw-in sensor \u003cbr\u003e\u003cb\u003eConstruction:\u003c\/b\u003e G1\/2\" thread \u003cbr\u003e\u003cb\u003eSensor housing: \u003c\/b\u003e Stainless steel 1.4404 (316 L, V4A) \u003cbr\u003e\u003cb\u003eTank media:\u003c\/b\u003e Diesel, water, waste water, faeces \u003cbr\u003e\u003cb\u003eMeasuring range: \u003c\/b\u003e 0 - 250 mbar \u003cbr\u003e\u003cb\u003eMeasuring resolution:\u003c\/b\u003e 1 cm \u003cbr\u003e\u003cb\u003eMax. tank height:\u003c\/b\u003e 250 cm \u003cbr\u003e\u003cb\u003eOperating temperature range: \u003c\/b\u003e 0 – 85 °C \u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003e L 87, Ø 35 mm \u003cbr\u003e\u003cb\u003eOutput signal: \u003c\/b\u003e DC 4 – 20 mA, 2-wire principle\u003cbr\u003e\u003cb\u003eOperating voltage: \u003c\/b\u003e 10 – 30 V DC via measuring line \u003cbr\u003e\u003cb\u003eWeight: \u003c\/b\u003e approx. 0.2 kg, without cable\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832164446545,"sku":"660200250","price":299.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/660200250_TDT.png?v=1776681427"},{"product_id":"cmb","title":"P.Bus Masterbus Interface CMB","description":"\u003cp\u003eTo integrate Mastervolt devices into the P-Bus, the CMB interface is used. This allows Masterbus data to be displayed on the PSL and PSM SystemMonitors and some settings to be made that are required in daily operation. All Mastervolt devices can be purchased from us.\u003c\/p\u003e\n\u003cp\u003eThe Masterbus Bridge provides data from the following Mastervolt devices:\u003c\/p\u003e\n\u003cp\u003eMasterShunt\u003c\/p\u003e\n\u003cp\u003eLithium battery MLI\u003c\/p\u003e\n\u003cp\u003eCombiMaster\u003c\/p\u003e\n\u003cp\u003eMass Combi Ultra\u003c\/p\u003e\n\u003cp\u003eChargeMaster\u003c\/p\u003e\n\u003cp\u003eChargeMaster plus\u003c\/p\u003e\n\u003cp\u003eMac Plus\u003c\/p\u003e\n\u003cp\u003eSolar Master SCM 60\u003c\/p\u003e\n\u003cp\u003eThe interface is powered via the Masterbus network.\u003cbr\u003eDelivery includes M12 T-piece.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions: \u003c\/b\u003e H 66 x W 78 x D 32 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832164708689,"sku":"071000030","price":379.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000030-CMB.png?v=1781000725"},{"product_id":"tpc-4","title":"P-Bus Temperature Interface TPC 4","description":"\u003cp\u003eInterface for 4 Temperature Sensors\u003c\/p\u003e\n\u003cp\u003eWith the TPC 4 temperature interface, important temperature values can be recorded. Up to 4 Temp-HT or Temp-BT temperature sensors can be connected per temperature interface. Up to four TPC 4s can be connected to the P-BUS. Individual limit values can be set for each temperature sensor, which generate an alarm message as soon as the limit values are exceeded or fallen below. Temperature-dependent actions can be switched via the CMR4 relay module.\u003c\/p\u003e\n\u003cp\u003eConnection via pluggable screw terminals.\u003cbr\u003eSupplied with M12 T-cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSupply voltage:\u003c\/b\u003e DC 8-32 V\u003cbr\u003e\u003cb\u003eCurrent consumption:\u003c\/b\u003e 8 mA\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 107 x W 85 x H 40 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832165462353,"sku":"071000104","price":179.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000104_TPC4.png?v=1776694386"},{"product_id":"cav","title":"P-Bus AC Interface CAV","description":"\u003cp\u003eAC interface in DIN rail housing for the P-BUS for measuring an AC phase 230 V \/ 50 Hz\u003c\/p\u003e\n\u003cp\u003eVarious devices are often available for visualizing the energy flow of the electrical AC system, which are already capable of providing data. This data needs to be collected and displayed.\u003c\/p\u003e\n\u003cp\u003eThe following devices already provide P-BUS-compatible AC data:\u003cbr\u003e. ACE series chargers\u003cbr\u003e. Shore power transfer units (LAU)\u003c\/p\u003e\n\u003cp\u003eThe following devices can provide P-BUS-compatible data via an interface:\u003cbr\u003e. Studer X-Tender devices (combi inverters and solar controllers)\u003cbr\u003e. Mastervolt devices (combi inverters)\u003c\/p\u003e\n\u003cp\u003eFor power sources and consumers without a P-BUS connection, an AC interface CAV is installed and configured accordingly.\u003c\/p\u003e\n\u003cp\u003eThe AC interface CAV records current and voltage from 230V AC devices and provides the information to the P-BUS:\u003cbr\u003e. AC system voltage [V]\u003cbr\u003e. AC system current [A]\u003cbr\u003e. Kilowatt hours consumed in kWh since last reset\u003cbr\u003e. Name of the source \/ consumer for unique identification\u003c\/p\u003e\n\u003cp\u003eThe electrical connection is made via screw terminals.\u003c\/p\u003e\n\u003cp\u003eConnection to the P-BUS via an M12 T-cable, which is included in the scope of delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent measurement range:\u003c\/b\u003e 16 A (int. shunt) 100 A (via external converter WAC)\u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003e L 76 x W 53 x H 46 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832165691729,"sku":"071000230","price":179.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000230-CAV.png?v=1781001331"},{"product_id":"shx-348","title":"P-Bus Battery Management Shunt SHX 348","description":"\u003cp\u003eDigital battery management shunt for installation in the negative battery cable\u003c\/p\u003e\n\u003cp\u003eThe SHX battery management shunt precisely measures the current, voltage, and capacity of the connected battery. The galvanically isolated P-BUS allows for the acquisition of battery data even from battery groups isolated from the on-board electrical system (e.g., emergency battery for radio systems or for electric drives). The active SHX shunt calculates the current battery capacity from the continuously measured current and voltage values, and the system monitor displays this in color within the battery symbol.\u003c\/p\u003e\n\u003cp\u003ePower supply is provided via the voltage measurement cable. M8 connection bolts.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent carrying capacity:\u003c\/b\u003e 300A, 600A 1min, 1500A 0.5s\u003cbr\u003e\u003cb\u003eCurrent consumption: \u003c\/b\u003e 20 mA (5 mA sleep-mode)\u003cbr\u003e\u003cb\u003eOperating voltage: \u003c\/b\u003e 8-64 V\u003cbr\u003e\u003cb\u003eMeasurement range: \u003c\/b\u003e 10 mA - 300 A\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 118 x W 40 x H 65 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832165921105,"sku":"071000348","price":145.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000348_Shunt_SHX348_f17dd212-4bc9-4ee8-90ee-a8c7b020805d.png?v=1775737504"},{"product_id":"cmt2","title":"P-Bus Tank Interface CMT3","description":"\u003cp\u003eP-BUS Interface for Integrating up to 4 Tank Sensors\u003c\/p\u003e\n\u003cp\u003eThe CMT2 interface is required to integrate tanks or tank sensors into the P-BUS network. It independently measures up to four different tank sensors and makes this information available to the P-BUS. Parameters such as sensor type, tank size, tank characteristic curve, alarm level, etc., are set via the system monitors \u003cb\u003ePSM2\u003c\/b\u003e and \u003cb\u003ePSL\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp\u003eConnection is made via pluggable screw terminals. Connection to the P-BUS via M12 network connector.\u003c\/p\u003e\n\u003cp\u003eAn M12 T-cable is included in the scope of delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperating voltage:\u003c\/b\u003e DC 8-32 V \u003cbr\u003e\u003cb\u003eCurrent consumption: \u003c\/b\u003e Standby: 7.5mA@13 V \u003cbr\u003eActive: 10 mA @ 13 V\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 107 x W 85 x H 40 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832166216017,"sku":"071000402","price":185.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000401-CMT2.png?v=1776696718"},{"product_id":"shx-648","title":"P-Bus Battery Management Shunt SHX 648","description":"\u003cp\u003eDigital battery management shunt for larger currents \/ consumers. M16 connection bolts. Matching distribution bar SAS4.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eCurrent carrying capacity:\u003c\/b\u003e 600A, 800A 1min, 2500A 0.5s\u003cbr\u003e\u003cb\u003eCurrent consumption: \u003c\/b\u003e 6 mA@12 V, 4 mA@24 V\u003cbr\u003e\u003cb\u003eOperating voltage: \u003c\/b\u003e 8-60 V\u003cbr\u003e\u003cb\u003eMeasurement range: \u003c\/b\u003e 10 mA - 600 A\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 185 x W 44 x H 75 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832166642001,"sku":"071000648","price":279.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071000648_Shunt_SHX648_a21f39ec-7ecc-40a1-aab1-cada7787a890.png?v=1775737474"},{"product_id":"dfs-24","title":"Flow Sensor DFS 24","description":"\u003cp\u003eFresh water flow sensor for connection to a digital tank monitor BTM(2), VTM(2) and the tank interface CMT(3).\u003cbr\u003eFlow rate 1-25 l\/min. Connection flange for hose 10-12 mm, cable length 20 cm. Pulse count: 1000 pulses\/L.\u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003eL 110 x W 23 x H 57 mm\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832166904145,"sku":"700030324","price":135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/700030324-DFS24.png?v=1780997661"},{"product_id":"pss","title":"P-BUS Daughter Monitor PSS","description":"\u003cp\u003eThe PSS System Monitor serves as a slave display for a \u003cb\u003ePSM2\u003c\/b\u003e or \u003cb\u003ePSL monitor\u003c\/b\u003e. It is equipped with a 2.4\" color touchscreen and displays available battery, tank, temperature, and energy data on four pages. It can be operated in parallel with an active PSM2 or PSL. No settings are required on the monitor for operation, as all system settings are taken from the main PSM2 or PSL monitor. The configuration of the connected components is also done on the main PSM2 or PSL monitor.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAn M12 T-cable is included in the scope of delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"font-size: 14px; background-color: var(--bgcolor-white); color: var(--wd-text-color);\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"font-size: 14px; background-color: var(--bgcolor-white); color: var(--wd-text-color);\"\u003eOperating voltage: 8 - 32 V DC\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent consumption: 65mA, stand-by: 11 mA\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions: W 105 x H 75 X D 35mm\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eInstallation cutout: W 87 x H 65 mm\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832167297361,"sku":"071002224","price":229.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071002224-PSS.png?v=1775737447"},{"product_id":"psm-3","title":"P-BUS System Monitor PSM 3","description":"\u003cp\u003eThe new P-Bus monitor PSM3 is more than just a battery or tank monitor. It adapts to your wishes and requirements! Depending on which P-BUS components are connected, the PSM monitor displays all information on the touch screen with a glass front accordingly, no more and no less. Configuration is done interactively on the monitor itself, without the need for an additional computer.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eIn the main menu, the menu items for which data is available from the connected devices are visible.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003eInformation and control options are clearly displayed in seven submenus for\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eTanks\u003c\/li\u003e\n\u003cli\u003eTemperatures\u003c\/li\u003e\n\u003cli\u003eEnergy flow AC and DC\u003c\/li\u003e\n\u003cli\u003eMain switches\u003c\/li\u003e\n\u003cli\u003eConsumers\u003c\/li\u003e\n\u003cli\u003eBilge pumps\u003c\/li\u003e\n\u003cli\u003eseparately and clearly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn M12-T cable and the two P-BUS terminators (terminating resistors) are included in the scope of delivery.\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperating voltage: 8 - 32 V\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent consumption: 86 mA, standby: 5 mA\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions: L 105 x W 105 x D 35 mm\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eInstallation cutout: 88 x 88 mm\u003c\/b\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832167559505,"sku":"071002233","price":369.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071002233_PSM3.png?v=1775737421"},{"product_id":"psl","title":"P-BUS System Monitor PSL","description":"\u003cp\u003eThe System Monitor PSL uses its 5” color touchscreen to display all available data from the electrical system across three different pages. The information display shows battery, tank, temperature, and bilge information. The energy page provides an overview of the status of the DC and AC systems. On the control page, the main switches and consumers can be switched.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIf you have more than eight information icons, the display can be virtually scrolled left or right by simply swiping. On the info and switch screens, you can arrange the displayed elements yourself, just as you are used to doing with your smartphone.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAn M12 T-cable and the two P-Bus terminators (terminating resistors) are included in the scope of delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eOperating voltage: \u003c\/b\u003e \u003cb\u003e 8 - 32 V\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent consumption: 90 mA, stand-by 10 mA @ 12V \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions: W 157.5 x H 105 x D 35 mm \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832167854417,"sku":"071002250","price":479.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071002250_PSL_main2.png?v=1775737322"},{"product_id":"bts-t","title":"Tank Monitor 2.4\" with NMEA Interface BTS-T","description":"\u003cp\u003eNTS tank monitor with NMEA2000 interface. 2.4\" color TFT touchscreen graphic display with brightness sensor for automatic adjustment of display brightness.\u003cbr\u003eIncludes NMEA 2000 interface cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e W 105 x H 75 x D 40 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832169623889,"sku":"071003070","price":229.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071003070_NTS.png?v=1775737288"},{"product_id":"bls","title":"Battery Monitor 2.4\" BLS","description":"\u003cp\u003e2.4\" TFT Touch Remote Display Panel for ACE Series Chargers\u003c\/p\u003e\n\u003cp\u003eThe combined digital battery\/charge monitor BLS provides information about the operating status of the ACE charger and allows all charging parameters to be set. The main view shows the current charging current, charging voltage, current charging phase, battery temperature and mains voltage. \u003cbr\u003ePower reduction can be set and silent mode activated via the touchscreen. \u003cbr\u003eA SHE 300 battery management shunt can be added as an optional extra.\u003c\/p\u003e\n\u003cp\u003eNo ACE-LIN interface is required for ACE 12\/60 and 24\/30 chargers.\u003cbr\u003eFor ACE 12\/25, 12\/40 and 24\/20 chargers, the ACE-LIN interface must be ordered for installation in the ACE charger.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e W 105 x H 75 x D 40 mm\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/wp-content\/uploads\/philippi\/Info\/philippi20DE-LADEGERAETE.pdf\" aria-label=\"Weitere Informationen\" tabindex=\"-1\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832169951569,"sku":"071003201","price":179.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071003201_3fc23d6b-7c8d-41c0-8732-c6935d2102fc.png?v=1775737259"},{"product_id":"bls-set","title":"Battery Monitor BLS Set","description":"\u003cp\u003eThe BLS battery monitor is a compact battery monitoring system for battery systems consisting of a 12 \/ 24 V starter battery and one or more parallel-connected 12 \/ 24 V consumer battery(ies). The 2.4\" TFT touch screen displays all important data of the entire battery system at a glance without having to press a button. The built-in brightness sensor automatically dims the screen in the dark, saving valuable energy.\u003cbr\u003e. Display of the current voltage, the current charging or discharging current, the remaining time, the battery temperature and the state of charge of the consumer battery(ies)\u003cbr\u003e. Further information on the use of the consumer battery(ies): number of charging cycles, deep discharges and average discharge depth\u003cbr\u003e. Warning of dangerous deep discharge by an adjustable acoustic alarm.\u003cbr\u003e. Suitable for all battery types such as acid, GEL, AGM and LiFePO4\u003c\/p\u003e\n\u003cp\u003eThe SHE 300 shunt is included in the scope of delivery of the BLS set.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe current software can be found in our download area\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eQuick guide to updating the monitor and shunt\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNominal voltage:\u003c\/b\u003e 12 \/ 24 V\u003cbr\u003e\u003cb\u003eCurrent consumption:\u003c\/b\u003e max. 50 mA @ 12 V, stand-by: 6 mA\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e W 105 x H 75 x D 40 mm\u003cbr\u003e\u003cb\u003eMounting cutout:\u003c\/b\u003e 87 x 65 mm\u003cbr\u003e\u003cb\u003eShunt current carrying capacity:\u003c\/b\u003e 300A, 600A 1 min, 1500A 0.5 s\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/wp-content\/uploads\/philippi\/Info\/philippi20DE-BAT.MONITOR.pdf\" aria-label=\"Weitere Informationen\" tabindex=\"-1\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832170344785,"sku":"071003210","price":265.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071003210_BLS-Set_d20fcfde-31bf-4876-8ce8-4452b7263c4e.png?v=1776773007"},{"product_id":"bls-set-plus","title":"Battery Monitor BLS Set Plus","description":"\u003cp\u003eBattery monitor BLS for displaying a 12\/24V consumer battery and a 12\/24V starter battery. 2.4\" TFT color touchscreen graphic display with brightness sensor.\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eExpand the BLS monitor into a full-fledged battery charge management system by connecting an ACE series charger:\u003cbr\u003eThe ACE-LIN interface integrated into the ACE automatic charger enables the BLS battery monitor to monitor and control the charging process of the ACE automatic charger to optimize charging. The AC mains voltage, the charging phase, the battery temperature, the charging voltage, and the charging current can also be read from the display. By pressing a button, the charging power can be reduced or SilentMode (fan off) can be activated. For further charging monitoring, a temperature alarm can be defined, for example.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003eThe SHE 300 shunt and the ACE-LIN interface are included in the BLS-Set Plus scope of delivery.\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe current software can be found in our download area\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eQuick guide for updating the monitor and the shunt\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRated voltage:\u003c\/b\u003e 12 \/ 24 V\u003cbr\u003e\u003cb\u003eCurrent consumption:\u003c\/b\u003e max. 50 mA @ 12V, stand-by: 6 mA\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e W 105 x H 75 x D 28 mm\u003cbr\u003e\u003cb\u003eInstallation cutout:\u003c\/b\u003e 87 x 65 mm\u003cbr\u003e\u003cb\u003eShunt current rating:\u003c\/b\u003e 300A, 600A 1min, 1500A 0.5s\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832170803537,"sku":"071003220","price":319.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071003220_BLS-Set.png?v=1776773536"},{"product_id":"btm2","title":"Battery Tank Monitor BTM2","description":"\u003cp\u003ehttps:\/\/youtube.com\/shorts\/bbxmMqXg6Uwhttps:\/\/youtu.be\/MfBSvrmpMEc\u003c\/p\u003e\n\u003ch3\u003eBattery, Tank and Charging Monitor BTM 2.\u003c\/h3\u003e\n\u003cp\u003eIntuitive, 3.5\" color TFT touchscreen graphic display with brightness sensor for automatic adjustment of display brightness. Includes NMEA 2000 interface.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eThe BTM 2 is the further development of the proven battery tank monitor BTM. It\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eincludes an integrated NMEA2000 interface, which provides the battery and\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003etank data to the NMEA2000 network.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eThis allows the battery and tank data to be displayed on compatible plotters.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003ein addition.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eAll components have been improved in terms of standby consumption, so the BTM2 can remain permanently connected to the battery without any problems.\u003c\/p\u003e\n\u003ch4\u003eNMEA 2000\u003c\/h4\u003e\n\u003cp\u003eThe N2K cable is additionally required for connection to the NMEA2000 network. The pluggable cable connects to an NMEA 2000 on-board network via a T-piece (5 0411 1149). If the connection to a Raymarine network is to be made via Seatalk, a Raymarine Seatalk\/NMEA 2000 adapter cable must also be installed (please order from Raymarine - A06045).\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eBattery Monitoring\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003ePrecise battery information on current voltage, charge or\u003c\/p\u003e\n\u003cp\u003edischarge current, remaining time, temperature and state of charge of the consumer battery. Historical values for the number of charging cycles, deep discharges and average discharge depth give you an overview of battery usage. The voltages of up to 2 starter or bow batteries can be monitored.\u003c\/p\u003e\n\u003cp\u003eThe SHE 300 shunt is not included in the scope of delivery of the BTM2 - please order it separately!\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSolar Yield Measurement\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eIf one or more solar panels are to be monitored, you can display the current yield of your solar panels using a power measurement shunt SHP300.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eTank measurement\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eAll known Philippi tank sensors such as TGT\/ TGW, UTV, TDS\/TDN and DFS can be connected, as can existing tank sensors from other manufacturers with 10-180Ω \/ 240-33Ω \/ 0-5 V \/ 0-10 V\/ 4-20 mA signals. Each tank can be individually configured for clear assignment, and adaptation to non-linear tank geometries is also possible. Individual tank alarms can be defined for monitoring.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlarm\/Relay contact\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eAlso new is the potential-free changeover contact with which\u003c\/p\u003e\n\u003cp\u003ein conjunction with a remote-controlled battery\u003c\/p\u003e\n\u003cp\u003emain switch FBR 265 enables voltage- and, importantly, capacity-dependent\u003c\/p\u003e\n\u003cp\u003eenergy management and deep discharge protection.\u003c\/p\u003e\n\u003cp\u003eThis allows consumers to be switched off early before impending\u003c\/p\u003e\n\u003cp\u003edeep discharge and not only when the battery\u003c\/p\u003e\n\u003cp\u003eis deeply discharged. This is particularly important for lithium battery systems,\u003c\/p\u003e\n\u003cp\u003ewhose flat discharge characteristic makes timely voltage shutdown\u003c\/p\u003e\n\u003cp\u003eimpossible.\u003c\/p\u003e\n\u003cp\u003eThe tank sensors, the \"SHE300\" shunt and the NMEA 2000 connection cable \"\u003ca href=\"https:\/\/www.philippi-online.de\/produkt\/n2k-kabel\/\"\u003eN2K cable\u003c\/a\u003e\" or the FBR265 relay must be ordered separately.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperating voltage: \u003c\/b\u003e8-64 V\u003cb\u003e \u003c\/b\u003e\u003cbr\u003e\u003cb\u003eCurrent consumption: \u003c\/b\u003emax. 70 mA @ 12V, Stand-by: 6 mA\u003cb\u003e \u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003eL 105 x W 105 x H 35 mm\u003cbr\u003e\u003cb\u003eInstallation cutout: \u003c\/b\u003e88 x 88 mm\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832171884881,"sku":"071004050","price":285.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071004050_BTM2.png?v=1775737175"},{"product_id":"blm-set","title":"Battery Monitor BLM2 Set","description":"\u003cp\u003eAll information about the battery system at a glance and optionally on your plotter via the NMEA 2000\/Seatalk NG interface.\u003cbr\u003eMonitoring of the consumer and starter battery via the SHE 300 shunt (included). Optional voltage monitoring of a third battery bank.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBy means of an additional SHP 300 shunt, the power and energy yield of a solar system can be read out.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eEffective protection against deep discharge and capacity-dependent energy management via the remote-controlled battery main switch FBR 265.\u003c\/li\u003e\n\u003cli\u003eOptional display of battery data on an NMEA 2000 plotter\u003ca href=\"https:\/\/www.philippi-online.de\/produkt\/n2k-kabel\/\"\u003e via N2K cable.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb style=\"font-size: 14px; color: var(--wd-text-color);\"\u003eNominal voltage: \u003c\/b\u003eDC 12V\/24V\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent consumption: \u003c\/b\u003emax. 70 mA @ 12V, Stand-by: 6 mA\u003cb\u003e \u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003eL 105 x W 105 x H 35 mm\u003cbr\u003e\u003cb\u003eMounting cutout: \u003c\/b\u003e88 x 88 mm\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832172278097,"sku":"071004210","price":319.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071004210_BLM-set-1.png?v=1776774558"},{"product_id":"ltm","title":"Battery Tank Monitor LTM for Lithium Batteries LB","description":"\u003cp\u003eLithium Battery Tank Monitor LTM\u003cbr\u003eBattery, Tank and Charging Monitor LTM. Intuitive 3.5\" color TFT touchscreen graphic display with brightness sensor for automatic adjustment of display brightness.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe optional tank sensors, the \"SHE 300\" shunt, and the \"ACE-LIN\" charger interface must be ordered separately!\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperating voltage:\u003c\/b\u003e 8-64 V\u003cbr\u003e\u003cb\u003eCurrent consumption:\u003c\/b\u003e max. 70 mA @ 12V, Stand-by: 6 mA\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 105 x W 105 x H 35 mm\u003cbr\u003e\u003cb\u003eMounting cutout:\u003c\/b\u003e 88 x 88 mm\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832172736849,"sku":"071004320","price":319.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071004050_BTM2_d7c18bfb-e480-4b6a-be13-4c5f040f717c.png?v=1777276574"},{"product_id":"sas-4","title":"Shunt Connection Bar 600A SAS 4","description":"\u003cp\u003eThe shunt connection bar is screwed onto the SHC 612 as a distributor to allow multiple cable connections (M12, 3x M10).\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003eL 140 x W 30 x H 30 mm\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832175685969,"sku":"080009014","price":55.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/080009014-SAS4.png?v=1780999853"},{"product_id":"tds-tdn-200","title":"Tank Probes TDS \/ TDN 200","description":"\u003cp\u003eThe TDS\/TDN tank probes are suspended as submersible probes to the bottom of a tank. The probe measures the current level in the tank via the hydrostatic pressure of the liquid. The PUR connection cable of the submersible probe contains a thin air hose for rear pressure compensation for the measuring cell. This automatically compensates for air pressure fluctuations and prevents measurement falsification.\u003cbr\u003eThe TDS\/TDN submersible probes are suitable for (diesel), water, wastewater and sewage tanks, but not for gasoline, kerosene, petroleum (EEx zone).\u003cbr\u003eA mounting flange is included in the scope of delivery.\u003c\/p\u003e\n\u003cp\u003eThe pressure probes are used in conjunction with a:\u003cbr\u003e. Tank monitor TCS \/ BTM \/ VTM\u003cbr\u003e. Tank interface CMT 2 (system monitors PSM\/PSL)\u003cbr\u003e. Interface UTI (analog (round) measuring instruments)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplication:\u003c\/b\u003e Submersible probe\u003cbr\u003e\u003cb\u003eConstruction:\u003c\/b\u003e PUR black submersible cable, 2.5 m long, oil-resistant\u003cbr\u003e\u003cb\u003eProbe housing:\u003c\/b\u003e Stainless steel 1.4404 (316 L, V4A)\u003cbr\u003e\u003cb\u003eTank media:\u003c\/b\u003e Diesel, water, wastewater, sewage (TDS 200) Water, wastewater, sewage (TDN 200)\u003cbr\u003e\u003cb\u003eMeasuring range:\u003c\/b\u003e 0 – 200 mbar\u003cbr\u003e\u003cb\u003eMeasurement resolution:\u003c\/b\u003e 1 cm\u003cbr\u003e\u003cb\u003eMax. tank height:\u003c\/b\u003e 200 cm\u003cbr\u003e\u003cb\u003eOperating temperature range:\u003c\/b\u003e 0 – 40 °C\u003cbr\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 97, Ø 22 mm\u003cbr\u003e\u003cb\u003eOutput signal:\u003c\/b\u003e DC 4 – 20 mA, 2-wire principle\u003cbr\u003e\u003cb\u003eOperating voltage:\u003c\/b\u003e 10 – 30 V DC via measuring line\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e approx. 0.2 kg, without cable\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Water","offer_id":52832177520977,"sku":"660251208","price":359.0,"currency_code":"EUR","in_stock":true},{"title":"Diesel","offer_id":53259314889041,"sku":"660261206","price":409.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/660261206_TDS200.png?v=1775729644"},{"product_id":"tsc","title":"P-Bus Main Switch Interface TSC","description":"\u003cp\u003eInterface for controlling an external battery disconnect switch 500A - FBR 500 (12 or 24V) with adjustable undervoltage protection and overvoltage shutdown. Control via external push button or P-BUS. All settings can be adjusted on the system monitor. Delivery includes M12-T-cable. Please order FBR 500 separately!\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNominal voltage:\u003c\/b\u003e 12 + 24 V DC\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQuiescent current:\u003c\/b\u003e 2 mA \u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 111 x W 90 x H 41 mm\u003cbr\u003e\u003ci\u003e\u003c\/i\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":52832178176337,"sku":"083020000","price":135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/083020000_TSC.png?v=1781000063"},{"product_id":"p-bus-system-monitor-psl-plus","title":"P-BUS System Monitor PSL Plus","description":"\u003cp\u003eThe System Monitor PSL uses its 5” color touchscreen to display all available data from the electrical system across three different pages. The information display shows battery, tank, temperature, and bilge information. The energy page provides an overview of the status of the DC and AC systems. On the control page, the main switches and consumers can be switched.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIf you have more than eight information icons, the display can be virtually scrolled left or right by simply swiping. On the info and switch screens, you can arrange the displayed elements yourself, just as you are used to doing with your smartphone.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAn M12 T-cable and the two P-Bus terminators (terminating resistors) are included in the scope of delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003eOperating voltage: \u003c\/b\u003e \u003cb\u003e 8 - 32 V\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCurrent consumption: 90 mA, stand-by 10 mA @ 12V \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions: W 157.5 x H 105 x D 35 mm \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":53419890475345,"sku":"071002251","price":499.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071002250-PSL.png?v=1768491184"},{"product_id":"m12-terminator","title":"M12-PBUS cable","description":"\u003cp\u003e\u003cspan\u003eM12 (NMEA2000) Extension Cable 0.5m\/1m\/2m\/5m\/10m\u003c\/span\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Männlich","offer_id":53420361548113,"sku":"504111151","price":8.9,"currency_code":"EUR","in_stock":true},{"title":"Weiblich","offer_id":53420361580881,"sku":"504111156","price":8.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/504111154.png?v=1768491168"},{"product_id":"p-bus-studer-bridge-xcom-can-bms","title":"P-BUS-Studer Bridge XCOM-CAN-BMS","description":"\u003cp\u003eThe Xcom CAN Bridge is required to display data from the Xtender inverter\/chargers and to configure settings from the system monitor. Power is supplied via the Xtender network.\u003cbr\u003eIncludes M12 T-cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDimensions:\u003c\/b\u003e L 113 x W 76 x H 25 mm\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"studer","offers":[{"title":"Default Title","offer_id":53423970713937,"sku":"700069043","price":379.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/700069042-xcom-can_c5f2d98b-2dd0-4f55-a1d2-99df16d4ed19.png?v=1780997885"},{"product_id":"connect-hub","title":"Connect Hub","description":"\u003cp data-start=\"0\" data-end=\"304\"\u003eDer Connect Hub ist die zentrale Schnittstelle für deine Bordelektronik und macht die Installation deines Displays so einfach wie nie zuvor. Alle Anschlüsse – von Tanksensoren über Shunts bis hin zu Batterien – werden übersichtlich an einem Ort gebündelt und lassen sich komplett werkzeuglos anschließen.\u003c\/p\u003e\n\u003cp data-start=\"306\" data-end=\"667\"\u003eStatt jede einzelne Leitung mühsam bis zum Monitor zu verlegen, verbindest du alle Komponenten direkt mit dem Connect Hub. Von dort aus führt nur noch ein einziges Kabel zum Display, an dem alle Daten zusammenlaufen. Das spart nicht nur Zeit bei der Installation, sondern reduziert auch den Verkabelungsaufwand erheblich und minimiert potenzielle Fehlerquellen.\u003c\/p\u003e\n\u003cp data-start=\"669\" data-end=\"932\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eDank der zentralen Verkabelung sorgt der Connect Hub für maximale Übersicht, eine saubere Installation und eine zuverlässige Signalübertragung. Die ideale Lösung für moderne, vernetzte Systeme, bei denen Effizienz, Ordnung und einfache Handhabung im Fokus stehen.\u003c\/p\u003e\n\u003cp data-start=\"596\" data-end=\"726\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eMaße: 100x100x30 \u003c\/p\u003e\n\u003cp data-start=\"596\" data-end=\"726\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eKabellänge: 10m\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":53515551244625,"sku":"071009000","price":79.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071009000_philippiconnecthub_front_neu.png?v=1779865581"},{"product_id":"addio","title":"PSU Switching Unit 9012-8 ADV","description":"\u003cp data-end=\"414\" data-start=\"0\"\u003eDie PSU 9012-8 ADV ist eine leistungsstarke und flexibel konfigurierbare Power-Distribution-Unit mit 8 Ein- und 8 Ausgängen. Sie liefert einen kontinuierlichen Gesamtstrom von 90 Ampere, der intelligent auf alle Ausgänge verteilt werden kann. Dank der vielseitigen Konfigurationsmöglichkeiten eignet sich die PSU ideal für anspruchsvolle Anwendungen im Fahrzeug-, Offroad-, Marine- oder Sonderfahrzeugbereich.\u003c\/p\u003e\n\u003cp data-end=\"470\" data-start=\"416\"\u003eZu den umfangreichen Funktionen gehören unter anderem:\u003c\/p\u003e\n\u003cul data-end=\"881\" data-start=\"472\"\u003e\n\u003cli data-end=\"533\" data-start=\"472\" data-section-id=\"zs12t1\"\u003eRelaisfunktionen wie Blinken, Dimmen und Timersteuerung\u003c\/li\u003e\n\u003cli data-end=\"595\" data-start=\"534\" data-section-id=\"a386ij\"\u003eElektronische Absicherung\u003c\/li\u003e\n\u003cli data-end=\"684\" data-start=\"596\" data-section-id=\"15iyu90\"\u003eIndividueller Batterieschutz pro Ausgang – wahlweise zeit- oder spannungsgesteuert\u003c\/li\u003e\n\u003cli data-end=\"751\" data-start=\"685\" data-section-id=\"pho3j3\"\u003eRegelbasierte Logikfunktionen für intelligente Schaltabläufe\u003c\/li\u003e\n\u003cli data-end=\"881\" data-start=\"752\" data-section-id=\"kw1kq4\"\u003eSteuern von Motoren, Ventilen, Druckpumpen, ...\u003c\/li\u003e\n\u003cli data-end=\"881\" data-start=\"752\" data-section-id=\"kw1kq4\"\u003eIndividuelle Programmierungen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1059\" data-start=\"883\"\u003eJeder Ausgang ist digital abgesichert und kann mit bis zu 25 Ampere pro Kanal belastet werden. Die Strombegrenzung ist dabei flexibel in 5-Ampere-Schritten einstellbar.\u003c\/p\u003e\n\u003cp data-end=\"1321\" data-start=\"1061\"\u003eDie Steuerung der Ausgänge erfolgt flexibel über unterschiedliche Signalarten. Neben klassischen Schaltern können sowohl digitale Signale als auch analoge Eingangssignale  verarbeitet und individuell konfiguriert werden.\u003c\/p\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"1493\" data-start=\"1323\"\u003eDarüber hinaus lassen sich mehrere SCUs problemlos in Reihe oder parallel betreiben, um das System flexibel zu erweitern und an individuelle Anforderungen anzupassen.\u003c\/p\u003e\n\u003ctable width=\"359\" height=\"35\" style=\"width: 97.9131%; height: 274.75px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 26.4px;\"\u003e\n\u003ctd style=\"width: 51.8851%; height: 26.4px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22.6671%; height: 26.4px;\"\u003e Standard 1\u003c\/td\u003e\n\u003ctd style=\"width: 24.7297%; height: 26.4px;\"\u003eIndividual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.95px;\"\u003e\n\u003ctd style=\"width: 51.8851%; height: 22.95px;\"\u003eOutput 1 \/ Sicherung \u003c\/td\u003e\n\u003ctd style=\"width: 22.6671%; height: 22.95px;\"\u003eDimmen \/ 10A\u003c\/td\u003e\n\u003ctd style=\"width: 24.7297%; height: 22.95px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.95px;\"\u003e\n\u003ctd style=\"width: 51.8851%; height: 22.95px;\"\u003eOutput 2 \/ Sicherung\u003c\/td\u003e\n\u003ctd style=\"width: 22.6671%; height: 22.95px;\"\u003eDimmen \/ 10A\u003c\/td\u003e\n\u003ctd style=\"width: 24.7297%; height: 22.95px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.95px;\"\u003e\n\u003ctd style=\"width: 51.8851%; height: 22.95px;\"\u003eOutput 3 \/ Sicherung\u003c\/td\u003e\n\u003ctd style=\"width: 22.6671%; height: 22.95px;\"\u003eDimmen \/ 10A\u003c\/td\u003e\n\u003ctd style=\"width: 24.7297%; height: 22.95px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.95px;\"\u003e\n\u003ctd style=\"width: 51.8851%; height: 22.95px;\"\u003eOutput 4 \/ Sicherung\u003c\/td\u003e\n\u003ctd style=\"width: 22.6671%; height: 22.95px;\"\u003eDimmen \/ 10A\u003c\/td\u003e\n\u003ctd style=\"width: 24.7297%; height: 22.95px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 51.8851%; height: 39.2px;\"\u003eOutput 5 \/ Sicherung\u003c\/td\u003e\n\u003ctd style=\"width: 22.6671%; height: 39.2px;\"\u003eleselampe On\/Off    \/ 10A\u003c\/td\u003e\n\u003ctd style=\"width: 24.7297%; height: 39.2px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.2px;\"\u003e\n\u003ctd style=\"width: 51.8851%; height: 55.2px;\"\u003eOutput 6 \/ Sicherung\u003c\/td\u003e\n\u003ctd style=\"width: 22.6671%; height: 55.2px;\"\u003e\n\u003cp\u003eKühlbox   On\/Off    \/ 15A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.7297%; height: 55.2px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 51.8851%; height: 39.2px;\"\u003eOutput 7 \/ Sicherung\u003c\/td\u003e\n\u003ctd style=\"width: 22.6671%; height: 39.2px;\"\u003eMultiplus On\/ OFF\u003c\/td\u003e\n\u003ctd style=\"width: 24.7297%; height: 39.2px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.95px;\"\u003e\n\u003ctd style=\"width: 51.8851%; height: 22.95px;\"\u003eOutput 8 \/ Sicherung\u003c\/td\u003e\n\u003ctd style=\"width: 22.6671%; height: 22.95px;\"\u003eDauer + \/ 5A\u003c\/td\u003e\n\u003ctd style=\"width: 24.7297%; height: 22.95px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e Die Eingänge sind immer zu den passenden Ausgängen angeordnet: Input 1= Output 1...\u003c\/p\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"1493\" data-start=\"1323\"\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Standard 1","offer_id":53918286184785,"sku":"700901280","price":419.0,"currency_code":"EUR","in_stock":true},{"title":"Individual","offer_id":53918286250321,"sku":"7009012822","price":519.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/700901280_addio_frontleuchtend.png?v=1778495730"},{"product_id":"dca2","title":"Battery Tank Monitor BTM2","description":"\u003cp\u003ehttps:\/\/youtube.com\/shorts\/bbxmMqXg6Uwhttps:\/\/youtu.be\/MfBSvrmpMEc\u003c\/p\u003e\n\u003ch3\u003eBattery, Tank and Charging Monitor BTM 2.\u003c\/h3\u003e\n\u003cp\u003eIntuitive, 3.5\" color TFT touchscreen graphic display with brightness sensor for automatic adjustment of display brightness. Includes NMEA 2000 interface.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eThe BTM 2 is the further development of the proven battery tank monitor BTM. It\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eincludes an integrated NMEA2000 interface, which provides the battery and\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003etank data to the NMEA2000 network.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eThis allows the battery and tank data to be displayed on compatible plotters.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003ein addition.\u003c\/p\u003e\n\u003cp style=\"font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; font-family: Verdana, Geneva, sans-serif; font-size: 14px;\"\u003eAll components have been improved in terms of standby consumption, so the BTM2 can remain permanently connected to the battery without any problems.\u003c\/p\u003e\n\u003ch4\u003eNMEA 2000\u003c\/h4\u003e\n\u003cp\u003eThe N2K cable is additionally required for connection to the NMEA2000 network. The pluggable cable connects to an NMEA 2000 on-board network via a T-piece (5 0411 1149). If the connection to a Raymarine network is to be made via Seatalk, a Raymarine Seatalk\/NMEA 2000 adapter cable must also be installed (please order from Raymarine - A06045).\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eBattery Monitoring\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003ePrecise battery information on current voltage, charge or\u003c\/p\u003e\n\u003cp\u003edischarge current, remaining time, temperature and state of charge of the consumer battery. Historical values for the number of charging cycles, deep discharges and average discharge depth give you an overview of battery usage. The voltages of up to 2 starter or bow batteries can be monitored.\u003c\/p\u003e\n\u003cp\u003eThe SHE 300 shunt is not included in the scope of delivery of the BTM2 - please order it separately!\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eSolar Yield Measurement\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eIf one or more solar panels are to be monitored, you can display the current yield of your solar panels using a power measurement shunt SHP300.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eTank measurement\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eAll known Philippi tank sensors such as TGT\/ TGW, UTV, TDS\/TDN and DFS can be connected, as can existing tank sensors from other manufacturers with 10-180Ω \/ 240-33Ω \/ 0-5 V \/ 0-10 V\/ 4-20 mA signals. Each tank can be individually configured for clear assignment, and adaptation to non-linear tank geometries is also possible. Individual tank alarms can be defined for monitoring.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eAlarm\/Relay contact\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eAlso new is the potential-free changeover contact with which\u003c\/p\u003e\n\u003cp\u003ein conjunction with a remote-controlled battery\u003c\/p\u003e\n\u003cp\u003emain switch FBR 265 enables voltage- and, importantly, capacity-dependent\u003c\/p\u003e\n\u003cp\u003eenergy management and deep discharge protection.\u003c\/p\u003e\n\u003cp\u003eThis allows consumers to be switched off early before impending\u003c\/p\u003e\n\u003cp\u003edeep discharge and not only when the battery\u003c\/p\u003e\n\u003cp\u003eis deeply discharged. This is particularly important for lithium battery systems,\u003c\/p\u003e\n\u003cp\u003ewhose flat discharge characteristic makes timely voltage shutdown\u003c\/p\u003e\n\u003cp\u003eimpossible.\u003c\/p\u003e\n\u003cp\u003eThe tank sensors, the \"SHE300\" shunt and the NMEA 2000 connection cable \"\u003ca href=\"https:\/\/www.philippi-online.de\/produkt\/n2k-kabel\/\"\u003eN2K cable\u003c\/a\u003e\" or the FBR265 relay must be ordered separately.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperating voltage: \u003c\/b\u003e8-64 V\u003cb\u003e \u003c\/b\u003e\u003cbr\u003e\u003cb\u003eCurrent consumption: \u003c\/b\u003emax. 70 mA @ 12V, Stand-by: 6 mA\u003cb\u003e \u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDimensions: \u003c\/b\u003eL 105 x W 105 x H 35 mm\u003cbr\u003e\u003cb\u003eInstallation cutout: \u003c\/b\u003e88 x 88 mm\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"philippi","offers":[{"title":"Default Title","offer_id":53556977795409,"sku":"070004000","price":285.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/070004000_DCA2.png?v=1776430570"},{"product_id":"controll-unit-pcu","title":"PCU Control Unit","description":"\u003cp data-end=\"580\" data-start=\"160\"\u003eDie PCU ist das intelligente Herzstück moderner Bordelektrik in Fahrzeugen. Als zentrale Steuer- und Überwachungseinheit vereint sie sämtliche relevanten Informationen und Funktionen in einem einzigen, übersichtlichen System. Anstelle vieler einzelner Anzeigen bietet die PCU ein intuitives Display, das Ihnen jederzeit volle Kontrolle über Ihr Fahrzeug ermöglicht.\u003c\/p\u003e\n\u003cp data-end=\"941\" data-start=\"582\"\u003eIm Mittelpunkt steht ein umfassendes Energiemanagement: Die PCU liefert präzise Echtzeitdaten zu Batteriezustand, Spannung, Stromfluss und Temperatur und sorgt gleichzeitig für eine sichere Überwachung der Starterbatterie. Ergänzt wird dies durch eine exakte Tanküberwachung für Frisch-, Grau- und Schwarzwasser – kompatibel mit den gängigsten Sensorsystemen.\u003c\/p\u003e\n\u003cp data-end=\"1240\" data-start=\"943\"\u003eBesonders anschaulich ist die integrierte Energiefluss-Darstellung. Sie visualisiert alle Energiequellen und Verbraucher im Fahrzeug, darunter Solaranlage, Ladebooster, Inverter und weitere Komponenten. So behalten Sie jederzeit den Überblick über Erzeugung, Speicherung und Verbrauch von Energie.\u003c\/p\u003e\n\u003cp data-end=\"1504\" data-start=\"1242\"\u003eNeben den technischen Kernfunktionen überzeugt die PCU durch hohen Bedienkomfort. Sie zeigt Innen- und Außentemperaturen an und ermöglicht die zentrale Steuerung verschiedenster Geräte über CI- und CAN-Bus – etwa Kühlschränke, Heizungen oder weitere Bordtechnik.\u003c\/p\u003e\n\u003cp data-end=\"1794\" data-start=\"1506\"\u003eDank umfangreicher Schnittstellen lässt sich die PCU flexibel und nahtlos in bestehende Bordnetzsysteme integrieren. In Kombination mit dem CONNECT HUB wird die Installation besonders effizient: Alle Sensoren werden zentral angeschlossen, während nur ein einziges Kabel zum Display führt.\u003c\/p\u003e\n\u003cp data-end=\"2000\" data-start=\"1796\"\u003eOptional kann das System durch die Smart Control Unit (SCU) erweitert werden. Damit wird die PCU zu einem leistungsstarken Lastmanagementsystem mit zusätzlichen Steuerungs- und Automatisierungsfunktionen.\u003ca class=\"clickable-chip color-info\" href=\"https:\/\/admin.shopify.com\/store\/philippi-elektrische-systeme-gmbh\/collections\/666740359505\" aria-label=\"Kollektion „P-Bus“ anzeigen\"\u003e\u003cspan class=\"content\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"philippi","offers":[{"title":"Mit Rahmen","offer_id":54005284405585,"sku":"071002255","price":479.0,"currency_code":"EUR","in_stock":true},{"title":"Rahmenlos","offer_id":54005297283409,"sku":"071002260","price":479.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/2341\/2817\/files\/071002255_PCL-Menu2.png?v=1777896457"}],"url":"https:\/\/www.philippi-online.de\/en\/collections\/bord-uberwachung.oembed?page=2","provider":"philippi elektrische systeme GmbH","version":"1.0","type":"link"}