Connection units
Shore power connections are installed on-board to ensure a safe and problem-
free power supply in accordance with GL - Germanischer Lloyd safety
regulations and the European Standards EN ISO 13297 for AC power
supply. An automatic RCBO-leakage protector in combination with a circuit breaker
switch, which interrupte the power by means of a 30 mA two-pole cut-off
in case of electrical fault, overloading and short circuit.
When mounting a shore power connection unit more than three meters
far from the source, a double pole circuit breaker switch is necessary
near the shore power connection on board to protect against electrical
accidents.
Shore power connectors have to be completely watertight protected
according to the IP 55 outside for rain protection or IP 56 to protect
against over and under flow.
Cables for AC 230 V installation such as DC12V/24V have to be carried
in separate channels. |
|
LAE 110 FA
|
Order-No: 0 1000 1105 |
|
Same as LAE 110 with additional double LED charging monitor for use of philippi charging units. |
Info
|
|
3130-F12B-H7T1-W24AB7-6A
3130-F12B-H7T1-W24AB7-10A
3130-F12B-H7T1-W24AB7-16A
|
Order-No: 1 3130 5006 Order-No: 1 3130 5010 Order-No: 1 3130 5016 |
|
Double pole AC 230 V double pole rocker switch/thermal circuit breaker.
Cut out dimensions 26,3 x 34,2 mm, Width 29,3mm |
Info
|
|