Distribution Panels Series 200

The power distribution panels series 200, combine user comfort through a simple design and technical dependability. Each circuit is switched and protected by a thermic circuit breaker with its own rocker switch (ETA 3130). It contains an integrated light diode that shows circuit status. In case of short circuit, the breaker switches automatically off and the light is off. Once the problem is corrected, the breaker can be manually pushed to ON position. The circuit breaker has an intern mechanism that will not react (turn on) during a problem in circuitry, there by protecting circuits.
Self adhesive labels are included.
Individual circuits are labelled with self adhesive labels that are placed in the space of the required circuit.

Circuit labels are available in following languages:

German, German Mobil(for cars), English, Dutch, Spanish, Danish, French

STV 204 Order-No: 0 2000 2040

4 power circuits with thermic contact breakers 10 A

Dimensions W 105 x H 105 x D 70 mm

Info
STV 204 SY Order-No: 0 2001 2041

4 power circuits with thermic contact breakers 10A. Display "Sailing Boat" with electronic monitor.

Dimensions W 105 x H 210 x D 70 mm

Info
STV 202 MS Order-No: 0 2001 2026

2 power circuits with thermic contact breakers 10A and display power boat with electronic monitor.

Dimensions W 210 x H 105 x D 70 mm

Info
STV 207 Order-No: 0 2000 2070

7 power circuits with thermic contact breakers 10 A, 2 sockets 21 mm.

Dimensions W 105 x H 210 x D 70 mm

Info
STV 227-12V
STV 227-24V
Order-No: 0 2001 2270
Order-No: 0 2002 2270

7 power circuits with thermal circuit breakers 10A, voltmeter with switch over 1-0-2.

Dimensions W 105 x H 210 x D 70 mm

Info
STV 208 Order-No: 0 2000 2080

8 power circuits with thermal circuit breakers 10 A

Dimensions W 210 x H 105 x D 70 mm

Info
STV 210 Order-No: 0 2000 2100

10 power circuits with thermic contact breakers 10 A.

Dimensions W 105 x H 210 x D 70 mm

Info
STV 214 12V
STV 214 24V
Order-No: 0 2001 2140
Order-No: 0 2002 2140

14 power circuits with thermal circuit breakers 10A, volt- and ampmeter (0-40 A), 3 control switches (0-1, 1-0-2, 1-2) for individual use.

Dimensions W 210 x H 210 x D 70 mm

Info
STV 215 Order-No: 0 2000 2150

15 power circuits with thermal circuit breakers 10A, Battery monitor BCM. Shunt SHA 150 or SHA 600 has to be ordered separately !

Dimensions W 210 x H 210 x D 70 mm

Info
STV 220 Order-No: 0 2000 2200

20 power circuits with thermal circuit breakers 10 A

Dimensions W 210 x H 210 x D 70 mm

Info
STV 222 Order-No: 0 2001 2220

20 power circuits with thermal circuit breakers 10 A, battery monitor BCM (alternatively monitors BLM or LCM can be ordered), tank monitor TCM 4, display sailing yacht incl. position light monitor POS6 with alarm, 2 sockets und 2 control switches (0-1, 1-0-2) for individual use. Shunt SHA 150 or SHA 600 has to be ordered separately!

Dimensions W 420 x H 210 x D 70 mm

Info
STV 224 Order-No: 0 2001 2240

24 power circuits with thermal circuit breakers 10 A, Battery monitor BCM (alternatively monitors TCM or LCM can be ordered), display sailing yacht incl. Position light monitor POS6 with alarm, 2 sockets und 2 control switches for individual use. Shunt SHA 150 or SHA 600 has to be ordered separately!

Dimensions W 420 x H 210 x D 70 mm

Info
STV 228 Order-No: 0 2000 2280

8 power circuits with thermal circuit breakers 10A, battery monitor BCM 1, tank monitor TCM 4, socket 12V und 2 control switches for individual use. Shunt SHA has to be ordered separately !

Dimensions W 210 x H 210 x D 70 mm

Info
STV 230 12V
STV 230 24V
Order-No: 0 2001 2300
Order-No: 0 2002 2300

20 power circuits with thermal circuit breakers 10A, voltmeter with switch over, ampmeter 0-40 A and tank level instrument. Moving coil gauge, class 1.5. Position light monitor POS6 with alarm. 1 socket

Dimensions W 420 x H 210 x D 70 mm

Info
STV 200-5 Order-No: 0 2000 2005

5 circuits with rocker switch (31,5x14 mm) and lamp diodes display. Rocker switches can exchanged to other models, please find on page 19.

Dimensions W 105 x H 105 x D 50 mm

Info
STV 223 Order-No: 0 2000 2230

Blank panel for 3 analog meters for individual choice (voltage, current, tank measurement). Meters has to be ordered separately. Panel can be installed also vertical!

Dimensions W 210 x H 105 x D 70 mm

Info
BPA 200 Order-No: 0 2800 2030

Panel to choose bilge pumps operation between manually on-off or automatic. Outlet is protected against overload and short circuit by a circuit breaker. A LED indicates the operation of the bilge pump. Dimensions well matched to the panels series 200.

Rated voltage DC 12/24 V
Rated current 16 A
Dimensions W 105 x H 52,5 x D 60 mm

Manual      Info
SKZ-D
SKZ-DK
SKZ-ES
SKZ-F
SKZ-GB
SKZ-NL
Order-No: 0 2900 1600
Order-No: 0 2900 1604
Order-No: 0 2900 1603
Order-No: 0 2900 1605
Order-No: 0 2900 1602
Order-No: 0 2900 1601

Labels matching the series STV 200

Have a look at the info-area above for more details.

3130-F11B-H7T1-W29AG3-6A
3130-F11B-H7T1-W29AG3-10A
3130-F11B-H7T1-W29AG3-16A
3130-F11B-H7T1-W29AG3-20A
3130-F11B-H7T1-W29AG3-30A
Order-No: 1 3130 2006
Order-No: 1 3130 2010
Order-No: 1 3130 2016
Order-No: 1 3130 2020
Order-No: 1 3130 2030

Single pole DC single pole rocker switch/thermal circuit breaker of compact design for snap-in panel mounting. Black with silver frame. Cut out dimensions 14,8 x 34,2 mm, Width 18 mm. Rated voltage DC 30 V, Current ratings 6...30 A.
(30 A: width like double pole version, cut out dimensions 26,3 x 34,2 mm, Width 29,3mm)
Info